Fabricante : Bosch
Arquivo Tamanho: 855.6 kb
Arquivo Nome :
|
por este dispositivo também tem outras instruções :
Facilidade de uso
Specify the appliance type (see rating plate). Repairs must only be carried out by authorised specialists, thus ensuring the safety of the appliance. Improper tampering will render all warranty claims null and void. Lamp replacement Caution: disconnect the power supply before replacing lamps (switch off the fuse)! Caution: lamps may still be hot shortly after use! Risk of burns. – Detach the ring from the lamp cover. Note: make sure that the glass will not fall out (Fig. 16). – Pull out the lamp (Fig. 17). Defective lamps must only be replaced by lamps of the same type! (12 V/20 W/G4 lampholder) Inserting the lamp – Insert the lamp in the lampholder. Note: do not touch the halogen lamps with your hands. Use a cloth and touch the lamp only on its edges. – Engage the lamp cover. – Connect the appliance to the mains again. 6. Assembly instructions 6.1 Technical data AH 530-190: Weight: 23.5 kg Dimensions: 898 x 550 mm AH 532-190: Weight: 21.5 kg Dimensions: 898 x 550 mm AH 530-120: Weight: 27.5 kg Dimensions: 1198 x 550 mm AH 532-120: Weight: 25.5 kg Dimensions: 1198 x 550 mm Electrical connection Pay attention to the rating plate data. The mains connecting cable must at least correspond to the type H 05 VV-F G 0,75. The appliance must only be connected by an authorised specialist. The specialist is responsible for perfect functioning of the appliance at its installation location. He must explain the operating principle of the appliance to the user with reference to the operating instructions. He must explain to the user how the appliance can be isolated from the mains whenever required. Connection possibilities The plug of the connecting cable is inserted into the socket that is located behind the duct cover on the wall. If this is not possible, the disconnection of all the poles of the appliance from the mains must be achieved by way of the domestic fuse, or by using an accessible disconnecting device with a contact gap of at least 3 mm. 6.2 Installation The applicable regulations of the energy supply companies and the regional construction regulations must be observed when installing the hood. The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appliances 600 mm and for gas appliances 700 mm. The wall hood was conceived for the exhaust air mode. The exhaust air can be routed into a separate exhaust air shaft or directly into the open through the outside wall. It is not allowed to pass the exhaust air into a flue or exhaust air chimney that is in operation or into a shaft that is linked to the heating basement. Consult the chimney sweep responsible for your district whenever you wish to pass the exhaust air into a chimney that is not in operation. During the course of planning, a chimney sweep must be consulted if a room air-dependent hearth is operated in the same room as the one in which a hood is operated in the exhaust air mode. Adequate incoming air must be ensured. The applicable construction and safety regulations must be observed. Adequate incoming air must be ensured if a wood, coal, gas or oil heater or an open hearth is operated in the same room as the one in which the hood is installed. Safe operation is possible whenever the partial vacuum in the place where the firing equipment is installed does not exceed 4 Pa (0.04 mbar). This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/exhaust air wall boxes or other technical means. Flexible aluminium pipes, corrosion-protected sheet metal pipes and exhaust air pipes whose material conforms to fire B1 in accordance with DIN 4102 can be used. Exhaust air pipes should have a nominal diameter of 150 mm. Pay particular attention to ensuring that – the exhaust air ducts and pipes are kept as short as possible – the pipes are not laid at an acute angle, but as bends and that they are inserted into the shaft at an inclined upward angle and – there are no cross-sectional constrictions in the upward direction (this reduces the volume flow). As standard, the blow-out opening of the wall hood is in the upward direction. To pass exhaust air through the outer wall, we recommend the use of our telescopic wall box TM 150-045 (O 150). Note: To prevent the ingress of water, e.g. condensate or rain water from an uncovered exhaust air shaft, our condensate separator RV 060-150 must be installed in the exhaust air line. The condensate separator must still be acciessible after installation. The duct units listed below are available depending on the height of the ceiling: Stainless steel-design ventilation duct: LK 530-010 for ceiling heights of 2.20 - 2.66 m LK 530-020 for ceiling heights of 2.66 -3.15 m Aluminium-design ventilation duct: LK 530-011 for ceiling heights of 2.20 - 2.66 m LK 530-021 for ceiling heights of 2.66 -3.15 m The dimensions above refer to a distance of 1.60 m from the floor to the bottom edge of the hood. If r...
Este manual também é adequado para os modelos :Hoods - AH532190/01 (855.6 kb)