10). The delayed shut-off time for all levels is ten minutes. After these ten minutes, the ventilation switches off, but the lighting stays on. Interval ventilation Interval ventilation is a special feature of this appliance which periodically activates the fan for five minutes every hour. You can activate this function by simultaneously pressing the 0 key and, depending on the required extraction capacity, the 1, 2 or 3 key (see Fig. 11). This mode of operation is indicated by alternating illumination of the key together with the corresponding fan level indicator. You can switch off interval ventilation by pressing the 0 key (see Fig. 12). Fig. 12 Fig. 10 or or or Fig. 9 or or Fig. 11 or or 9 Cleaning the grease filters The grease filter saturation display F flashes after an operating time of 30 hours to indicate that you should clean the grease filters (see Fig. 3). The grease filters can of course be cleaned at any time, even if the grease filter saturation display has not started to flash. The stainless steel grease filters can be removed easily for cleaning (see Fig. 13): Disconnect the power supply (switch off the fuse). Grip the grease filter handle and push the slide towards the rear. Then pull the grease filter downwards out of the holder; repeat the operation for the other grease filters. You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 65°C, where it should be supported vertically to allow food or rinsing residues to drain off. If possible, the inner parts of the housing should be wiped out in hot rinsing water when replacing the filters. Caution: when cleaning the inside of the housing, beware of protruding parts. After having cleaned them, re-insert the grease filters in the extractor hood in reverse order. Note: the handles of the grease filters must be visible after assembly. Press the F key to set the elapsed hours counter to zero. Flashing of the indicating lamp goes off. 4. Cleaning and care Fig. 13 Fig. 14 Fig. 15 Fig. 15 Cleaning the extractor hood Clean the extractor hood and the aluminium- design ventilation ducts (LK 590-011/021/031) with a soft cloth and mild detergent solution only. Clean the stainless-steel design ventilation ducts (LK 590-010/020/030) with mild detergent solution and apply stainless steel care agent to the metal surface using a soft cloth. Cleaning the glass plates Apply commercially available window cleaning agent with a soft, moist cloth. To facilitate cleaning, you can detach the glass plates as follows: Detach the grease filters. In the extractor hood, you will find two openings on the upper side through which you can lift the glass plates singly with a blunt object (e.g. handle of a wooden spoon) to detach them with greater ease. The remaining glass plates can then be lifted from above. If they are extremely soiled, the glass plates can be cleaned in a dishwasher at a maximum temperature of 55 °C. Note: when putting the glass plates back in place, make sure that you do not scratch the chimney. Replace the glass plates with the printed side facing down. Position the glass plates at the chimney side first. Cleaning the aluminium panel Clean the control panel with a sponge and mild detergent solution only. Dry with a soft, dry cloth. Do not use any strong or caustic cleaning agents or brushes and abrasive cleaner to clean it. Do not use strongly alkaline cleaning agents (such as oven spray) because these are aggressive to the aluminium surface. Do not use any abrasive sponges either. 5. Maintenance Fig. 16 Fig. 17 First disconnect the appliance from the mains before carrying out any repairs. In the event of malfunctions, first check the household fuses. If the power supply is in proper working order, but the appliance is nevertheless not functioning, then please contact your specialist dealer or your responsible Gaggenau after-sales service. Specify the appliance type (see rating plate). Repairs must only be carried out by authorised specialists, thus ensuring the safety of the appliance. Improper tampering will render all warranty claims null and void. Lamp replacement Caution: disconnect the power supply before replacing lamps (switch off the fuse)! Caution: lamps may still be hot shortly after use! Risk of burns. – Detach the ring from the lamp cover. Note: make sure that the glass will not fall out (Fig. 16). – Pull out the lamp (Fig. 17). Defective lamps must only be replaced by lamps of the same type! (12 V/20 W/G4 socket) Inserting the lamp – Insert the lamp in the socket. Note: do not touch the halogen lamps with your hands. Use a cloth and touch the lamp only on its edges. – Replace the lamp cover. – Connect the appliance to the mains again. 6. Assembly instructions 6.1 Technical data Weight without support frame and LK: AH 590: 35 kg AH 592: 33 kg Weight with support frame and LK: max. 60 kg Dimensions: 1198 x 700 mm Electrical connection Pay attention to the rating plate data. The mains connecting cable must...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias