|
Facilidade de uso
Exhaust air may be discharged in accordance with official and statutory regulations only (e.g. national builing regulations). Local authority regulations must be observed when discharging air into smoke or exhaust air flues that are not otherwise in use. • When the extractor hood is operated in exhaust-air mode simultaneously with a different burner (such as gas, oil or coal-fired heaters, continuous-flow heaters, hot-water boilers) care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion. Safe operaration is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa (0,04 mbar). This can be achieved if combustion air can flow through non- lockable openings, e.g. in doors, windows and via the airintake/ exhaust air wall box, or by the other technical measures, such as reciprocal interlocking. Etc… If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded. Note: when assessing the overall requirement, the combined ventilation system for the entire household must be taken into considertion. This rule does not apply to the use of cooking appliances, such as hobs and ovens. If the exhaust air is going to be discharged into the open, a telescopic wall box should be fitted into the outside wall. Operating procedure To activate the functions simply tap the buttons. If the buttons are pressed for too long, no function is activated. The most effective method of removing vapours produced during cooking is to: • Switch the ventilator ON as soon as you begin cooking. • Switch the ventilator OFF a few minutes after you have finished cooking. Light Speeds Timer Indicator It switches motor off It decreases the speeds It switches motor on and increases the speeds Acoustic signal • When a push button is pressed, this is verified by an acoustic signal. Switching the fan ON • Press the + Push button Setting the required fan speed • Press the + Push button The fan speed is increased by one step. • Press the -Push button The fan speed is reduced by one step. Switching the fan OFF • Press the O Push button the displayed goes out shortly afterwards. Or • Keep pressed the – push button until the fan switches off. The displayed goes out shortly afterwards. Intensive Setting: Maximum power is obtained at the intensive setting. It is only required for short intervals. • Keep pressed the + button until a appears in the display. • If the intensive setting is not cancelled by hand, the fan will automatically switch back to step after 10 minutes. Fan follow on: • Press the . button The fan continues to run at step for 10 minutes and at the same time a dot flashes in the display. After this period the fan switches off automatically. Lighting: • The light can be switched on at any time, even though the fan is switched on. Remote control: The remote control is set up by the manufacturer. If the remote control is not controlling motor or light nearby the cooker hood, please do the following. Set up of the remote control. Keep pressing the “+” button of the remote control and then connect the cooker hood, to confirm that the remote control has been recognized a long beep is issued. If you do not hear the acoustic signal within 30 seconds, please repeat the steps as described. Functions of the remote control. The +, -, and Light Push button have the same functions as on the controls of the hood. The : Push button has the same function as the . Interval Function: A specific function of this appliance is the Interval Function which consists in activating the motor in automatic way 10 minutes each hour at the speed flashing in the display. This function can be activated on the control of the hood or by remote control. Interval Function by controls: • Keep pressing at the same time the O and + push buttons, then release them: the display will show the 1; • Keep pressing at the same time the + push button, the display will show the following for the speeds of the motor 2>3>1>2 …; • Keep pressing at the same time the O and + push buttons to confirm the speed for the motor you wish for the interval function. Interval Function by remote control: • Keep pressing the : push button. The display will show 1; • Keep pressing the + push button, the display will show the following for the speeds of the motor 2>3>1>2 …; • Press the push button to confirm the speed of the motor for the interval function. When you are in the setting phase, if the interval function shown is not confirmed within some seconds, then you get out of the setting mode for the interval function. By pressing any push button, light excluded, the interval function is excluded. The remote control has a battery – When the battery is exhausted you need to: 1. loosen the 2 screws on the rear part and remove the cover. ...
Este manual também é adequado para os modelos :Hoods - DID09T950/02 (741.06 kb)
Hoods - DID09T950/03 (741.06 kb)