Fabricante : Bosch
Arquivo Tamanho: 2.88 mb
Arquivo Nome :
|
Facilidade de uso
If no one-way flap was enclosed with the hood, it can be obtained from a specialist retailer. Attaching the one-way flap: . Insert the two lugs on the one-way flap into the holes on the air-pipe connector or air outlet and lock into position. Before installing the one-way flap, ensure that the lettering or stamp is on the outside. If the exhaust air is going to be discharged into the open, a telescopic wall box should be fitted into the outside wall. For optimum extractor hood efficiency: . Short, smooth air exhaust pipe. . As few bends in the pipe as possible. . Diameter of pipe to be as large as possible and no tight bends in pipe. If long, rough exhaust-air pipes, many pipe bends or smaller pipe diameters are used, the air extraction rate will no longer be at an optimum level and there will be an increase in noise. . Round pipes: We recommend Internal diameter: 150 mm. . Flat ducts must have an internal cross- section that equates to that of round pipes. There should be no sharp bends. l150 mm approx. 177 cm2 . If pipes have different diameters: Insert sealing strip. . For exhaust-air mode, ensure that there is an adequate supply of fresh air. Pipe connection . Screw the enclosed air-pipe connector over the air outlet. 150 mm lextraction pipe: . Attach the exhaust-air pipe directly to the air outlet. If a one-way flap has been fitted, conduct a performance test. Prior to installation Circulating-air mode . With activated carbon filter if exhaust-air mode is not possible. 600/700/900/ 1000/1100/1200 The complete installation set can be obtained from specialist outlets. Preparing the wall . The wall must be flat and perpendicular. . Ensure that the wall is capable of providing a firm hold for mounting screws and plugs. Weight in kg: Exhaust air Recirculating air 60 cm 15,0 17,0 70 cm 16,0 18,0 90 cm 17,5 19,5 100 cm 19,0 21,0 110 cm 21,0 23,0 120 cm 23,0 25,0 We reserve the right to construction changes within the context of technical development. Electrical connection WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Fitting a Different Plug: The wires in the mains lead are coloured in accordance with the following code: Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals. Electrical connection This is what you have to do: 1.Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2.Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 3.Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red. The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations. If possible, site the earthed socket directly behind the chimney panelling. Electrical data: Are to be found on the name plate inside the appliance after removal of the filter frame. Before undertaking any repairs, always disconnect the extractor hood from the electricity supply. Length of the connecting cable: 1.30 m. If it is necessary to wire the extractor hood directly into the mains: The extractor hood should only be connected to the electricity supply by a properly qualified electrician. A separator must be installed in the household circuit. A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles. Such devices include circuit breakers and contactors. If the connecting cable for this appliance is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user. This extractor hood corresponds to EC regulations concerning RF interference suppression. 23 Installation This extractor hood is intended to be mounted onto the kitchen wall. 1. Remove the grease filter (refer to Operating Instructions). 2. Draw a line on the wall from the ceiling to the lower edge of the hood at the centre of the location where the hood is going to be mounted. 3. Using the template, mark positions on the wall for the screws. Ensure that the minimum distance between the hob and the extractor hood is maintained – 550 mm for an electric hob and 650 mm for a gas hob. The bottom edge of the template equates to the lower edge of the extractor hood. 4. Drill 4 x l 8 mm holes for the extractor hood and 2 x l 8 mm holes for the chimney panelling. Insert plugs into the holes so that they are flush with the wall. Note: Take into account any special accessories that are going to be fitted. 5. Attach the 2 enclosed spacers to the fixing bracket for the flue duct panelling. Attach the fixing bracket for the chimney panelling using two hexagon head cap screws. 6. Screw in the two upper hexagon head cap screws leaving them extended by approx. 5 mm. 7. Attach the extract...
Este manual também é adequado para os modelos :Hoods - DKE645K/01 (2.88 mb)
Hoods - DKE745K/01 (2.88 mb)
Hoods - DKE945K/01 (2.88 mb)