Instruções de Operação Bosch, Modelo DKE645MGB/01

Fabricante : Bosch
Arquivo Tamanho: 760.65 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Gap at least 50 mm. Minimum distance on gas hotplates between the upper edge of the trivet and lower edge of the extractor hood: 650 mm, Fig. 1. Prior to installation Exhaust-air mode 120 120 280 260 mind. 45 684-1086 136 mind. 490 mind. 510 mind.60 500 600/900 The exhaust air is discharged upwards through a ventilation shaft or directly through the outside wall into the open. DExhaust air should neither be directed into a smoke or exhaust flue that is currently used for other purposes, nor into a shaft that is used for ventilating rooms in which stoves or fireplaces are also located. Exhaust air may be discharged in accordance with official and statutory regulations only (e.g. national building regulations). Local authority regulations must be observed when discharging air into smoke or exhaust flues that are not otherwise in use. DWhen the extractor hood is operated in exhaust-air mode simultaneously with a different burner which also makes use of the same chimney (such as gas, oil or coal-fired heaters, continuous-flow heaters, hot-water boilers) care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion. Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa (0.04 mbar). This can be achieved if combustion air can flow through non-lockable openings, e.g. in doors, windows and via the airintake/ exhaust-air wall box or by other technical measures, such as reciprocal interlocking, etc. If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded. Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens. Unrestricted operation is possible if the extractor hood is used in recirculating mode – with activated carbon filter. If the exhaust air is going to be discharged into the open, a telescopic wall box should be fitted into the outside wall. Prior to installation For operating in exhaust-air mode, a one-way flap should be mounted inside the extractor hood unless there is already one fitted in the outlet duct or wall ventilation box. If no one-way flap was enclosed with the hood, it can be obtained from a specialist retailer. Installing the one-way flap: . Snap the one-way flap into the air pipe. The two lightly sprung flaps must be able to move upwards. For optimum extractor hood efficiency: . Short, smooth air exhaust pipe. . As few bends in the pipe as possible. . Diameter of pipe to be as large as possible and no tight bends in pipe. If long, rough exhaust-air pipes, many pipe bends or smaller pipe diameters are used, the air extraction rate will no longer be at an optimum level and there will be an increase in noise. . Round pipes: We recommend Internal diameter: 125 mm (at least 100 mm). . Flat ducts must have an internal cross- section that equates to that of round pipes. There should be no sharp bends. l100 mm approx. 78 cm2 l125 mm approx. 113 cm2 . If pipes have different diameters: Insert sealing strip. . For exhaust-air mode, ensure that there is an adequate supply of fresh air. Connecting a l125 mm exhaust-air pipe: . Mount the pipe directly onto the air outlet on the hood. Connecting a l100 mm exhaust-air pipe: . Attach the reducing connector (enclosed or available from specialist retailer) to the air pipe and then attach to the exhaust-air duct. Prior to installation Circulating-air mode . With activated carbon filter if exhaust-air mode is not possible. 280 260 mind. 45 775-1187 136 mind. 490 500 600/900 The complete installation set can be obtained from specialist outlets. The corresponding accessory numbers can be found at the end of these operating instructions. Preparing the wall . The wall must be flat and perpendicular. . Ensure that the wall is capable of providing a firm hold for mounting screws and plugs. Weight in kg: Exhaust air Recirculating air 60 cm 19,0 21,0 90 cm 21,5 23,5 We reserve the right to construction changes within the context of technical development. Electrical connection WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Fitting a Different Plug: The wires in the mains lead are coloured in accordance with the following code: Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals. Electrical connection This is what you have to do: 1.Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2.Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 3.Connect the brown (Live) wire ...

Este manual também é adequado para os modelos :
Hoods - DKE745MGB/01 (760.65 kb)
Hoods - DKE945MGB/01 (760.65 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias