Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Bosch, Modelo DKE665MGB/01

Fabricante : Bosch
Arquivo Tamanho: 742.44 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


As few bends in the pipe as possible. . Diameter of pipe to be as large as possible and no tight bends in pipe. If long, rough exhaust-air pipes, many pipe bends or smaller pipe diameters are used, the air extraction rate will no longer be at an optimum level and there will be an increase in noise. . Round pipes: We recommend Internal diameter: 150 mm (at least 120 mm). . Flat ducts must have an internal cross- section that equates to that of round pipes. There should be no sharp bends. l120 mm approx. 113 cm2 l150 mm approx. 177 cm2 . If pipes have different diameters: Insert sealing strip. . For exhaust-air mode, ensure that there is an adequate supply of fresh air. Circulating-air mode . With activated carbon filter if exhaust-air mode is not possible. Connecting a l150 mm exhaust-air pipe: . Mount the pipe directly onto the air outlet on the hood. Connecting a l120 mm exhaust-air pipe: . Attach the reducing connector directly to the air pipe. . Attach the exhaust-air pipe to the reducing connector. The complete installation set can be obtained from specialist outlets. The corresponding accessory numbers can be found at the end of these operating instructions. 280 260 550 630 600/700/900 mind. 130 808-1 190 mind.38 48 520 Prior to installation Preparing the wall . The wall must be flat and perpendicular. . Ensure that the wall is capable of providing a firm hold for mounting screws and plugs. Weight in kg: Exhaust air Recirculating air 60 cm 22,0 27,4 70 cm 23,0 28,4 90 cm 25,1 30,5 We reserve the right to construction changes within the context of technical development. Electrical connection WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Fitting a Different Plug: The wires in the mains lead are coloured in accordance with the following code: Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals. This is what you have to do: 1.Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2.Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 3.Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red. The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations. If possible, site the earthed socket directly behind the chimney panelling. Electrical connection Electrical data: Are to be found on the name plate inside the appliance after removal of the filter frame. Before undertaking any repairs, always disconnect the extractor hood from the electricity supply. Length of the connecting cable: 1.30 m. If it is necessary to wire the extractor hood directly into the mains: The extractor hood should only be connected to the electricity supply by a properly qualified electrician. A separator must be installed in the household circuit...

Este manual também é adequado para os modelos :
Hoods - DKE665MGB/03 (742.44 kb)
Hoods - DKE665PGB/01 (742.44 kb)
Hoods - DKE667EGB/01 (742.44 kb)
Hoods - DKE765MGB/01 (742.44 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias