Facilidade de uso


Light bulbs must always be fitted when the extractor hood is in use. Defective bulbs should be replaced immediately to prevent the remaining bulbs from overloading. Never operate the extractor hood without a grease fi lter. Overheated fat or oil can easily catch fire. If you are cooking with fat or oil, e.g. chips, etc., never leave the cooker unattended. Carefully clean the extractor hood before switching on for the fi rst time. 16 Operating the extractor hood The most effective method of removing vapours produced during cooking is to: .. Switch the ventilator ON as soon as you begin cooking. .. Switch the ventilator OFF a few minutes after you have fi nished cooking. Key Function Display A Switches the extractor motor on and off at the latest selected speed It shows the selected speed B Decreases the suction speed. C Increases the suction speed. D By pressing this key it ispossible to activate the intensive speed from anypreviously selected speed. This speed has been timedat 10 minutes. After that time the system activates automatically the latest selectedspeed. It shows H E By pressing this key it is possible to set the delayed shutdown of the appliance to 30 minutes. This function is suitable for a complete elimination of the residual smells. It can be activated at any position, and it is deactivated by pressing the key again or by switching off the motor. The point low to right flashes. F With a short press, turns light on and off. With an extended press, turns light on and off at reduced intensity. en 17 18 en Filters and maintenance .. Unhook the security chain by opening the shackle, then lift the grid upward. .. Remove the fi lters one by one. .. Any kind of bending of the fi lters has to be avoided when washing them. Before fi tting them again into the hood make sure that they are completely dry. (The colour of the fi lter surface may change throughout the time but this has no infl uence to the fi lter effi ciency). .. Put the clean fi lters back on the Grid in its place .. Hook the security chain and put back the Grid onto the hood. Reset of the alarm signal .. Switch off the hood and the lighting. .. Press the E-key until the display is unlit. Grease fi lters: Metal-mesh fi lters are used to trap the grease particles in the cooking vapours. The fi lter mats are made from noncombustible metal. Caution: As the fi lter becomes more and more saturated with grease, there is an increased risk of fi re and the function of the extractor hood may be impaired. Important: By cleaning the metal grease fi lters at appropriate intervals, the possibility of them catching fi re as a result of a build-up of heat such as occurs when deepfat frying or roasting is taking place, is reduced. Filters can be washed in the dish machine. They need to be washed when F-sign appears on the display or in any case every month, or even more frequently in case of particularly intensive use of the hood. Removing and inserting metal self- supporting grease fi lters .. First unhook the fi lter-holding Grid by acting on the special Handles. Filters and maintenance Activated carbon filter: For neutralizing odours in recirculating mode. Caution: As the filter becomes more and more saturated with grease, there is an increased risk of fire and the function of the hood may be impaired. Important: Change the activated carbon filter promptly to prevent the risk of fire from the accumulation of heat when deep-fat frying or roasting. These filters are not washable and cannot be regenerated, and must be replaced when the C-sign appears on the display or approximately every year of operation, or more frequently with heavy usage. Activation of the alarm signal In the recycling version hoods the fi lter saturation alarm must be activated during the installation or later. .. Switch off the hood and the lights. .. Disconnect the hood from the mains supply. .. When restoring the connection press and hold B-key. .. When releasing the key two rotating rectangles appear on the display. .. Within 3 seconds press the B-key until a flashing confirmation appears on the dispaly: .. 2 fl ashes with C-sign - charcoal fi lter saturation alarm ACTIVATED .. 1 fl ash with C-sign - charcoal fi lter saturation alarm DEACTIVATED. Replacing the activated carbon filter Reset of the alarm signal • Switch off the hood and the lighting. .. Press the E-key until the display is unlit. Replacing of the filter .. Unhook the filter-holding Grid (see “Removing and inserting metal self- supporting grease filters”) .. Remove the saturated activated carbon fi lter as shown (A). en B A .. Fit the new fi lters (B). Filter can be ordered at the customer service .. Hook the filter-holding Grid (see “Removing and inserting metal self- supporting grease filters”) Disposal of the old activated carbon filter: .. Activated carbon filters do not contain any harmful substances. They can be disposed of as residual waste. 19 Cleaning and care Isolate the extractor hood by pulling out the ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias