Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Bosch, Modelo DKE985F/01

Fabricante : Bosch
Arquivo Tamanho: 5.3 mb
Arquivo Nome :
Língua de Ensino: itenesfrdenlpt
Ir para baixar



Facilidade de uso


Carefully clean the extractor hood before switching on for the first time. Do not place any objects on the extractor hood. When moving the filter drawer, do not place hand in the marked areas, danger of crushing! The sliding surfaces of the filter drawer must not be dirty. Slide marks may occur. However, these will not impair function. 19 Operating procedure . The most effective method of removing vapours produced during cooking is to: . Switch the ventilator ON as soon as you begin cooking. . Switch the ventilator OFF a few minutes after you have finished cooking. Display for fan setting Light Fan follow-onFan OFF Reduce fan Fan ON and speed increase speed Acoustic signal: . When a button is pressed, this is verified by an acoustic signal. Switching off the acoustic signal: . Simultaneously press buttons 0 and + until a signal is emitted after approx. 3 seconds. Switching on the acoustic signal: . Repeat the process. Switching the fan ON . Press the + button or pull out the filter drawer. Setting the required fan speed: . Press the + button. The fan speed is increased by one step. . Press the – button. The fan speed is reduced by one step. Switching the fan OFF: . Press the 0 button. The displayed { goes out shortly afterwards. Or: . Keep pressing the – button until the fan switches off. The displayed { goes out shortly afterwards. Intensive setting: Maximum power is obtained at the intensive setting. It is only required for short intervals. . Keep pressing the + button until a c appears in the display. . If the intensive setting is not cancelled by hand, the fan will automatically switch back to step } after 10 minutes. Fan follow-on: . Press the ! button or push in the filter drawer. The fan runs for 10 minutes at setting 1. At the same time a dot flashes in the display. Then the fan switches off automatically. Lighting: . Briefly press the a button to switch the light on and off. . The light can be switched on at any time, even though the fan is switched off. . Adjusting the brightness: Hold down the a button until the desired brightness is obtained. Switching on the light automatically, e.g. via a timer: . Fan and light must be switched off. Switching on: Simultaneously press the – and ! buttons. . After approx. 3 seconds the light switches on to acknowledge the setting. Switching off: Repeat the process with the light switched on. . After approx. 3 seconds the light switches off to acknowledge the setting. Filters and maintenance Grease filters: Metal filters are used to trap the greasy element of the vapours that develop during cooking. The filter mats are made from noncombustible metal. Caution: As the filter becomes more and more saturated with grease, not only does the risk of it catching fire increase but the efficiency of the extractor hood can also be adversely affected. Important: By cleaning the metal grease filters at appropriate intervals, the possibility of them catching fire as a result of a build-up of heat such as occurs when deep-fat frying or roasting is taking place, is reduced. Saturation indicator: ~ When the grease filters reach saturation point, an acoustic signal is sounded for 6 seconds after the fan has switched off, and an ~ appears in the display. The grease filters should be cleaned straight away. Cleaning the metal grease filters: . In normal operation (1 to 2 hours daily), the metal grease filter must be cleaned 1 x a month. . The filters can be cleaned in a dishwasher. It is however possible that they will become slightly discoloured. . The filter must be placed loosely, and NOT wedged, in the dishwasher. Important: Metal filters that are saturated with grease should not be washed together with other dishes etc. . When cleaning the filters by hand, soak them in hot soapy water first of all. Do not use aggressive, acidic or caustic cleaners. Then brush the filters clean, rinse them thoroughly and leave the water to drain off. Removing and inserting the metal grease filters: Warning: The halogen bulbs must be switched off and cool. . Before changing the grease filters, ensure that the filter drawer has been pushed in. 1. Press the catches on the front grease filters and fold down the grease filters. 2. Press the catches on the rear grease filters and fold down the grease filters. 3. Clean the grease filter. 4. Insert the clean filters back into the hood. 5. Cancel the ~ in the display. . Press the button 0. Filters and maintenance 5. Insert the metal grease filters (see "Removing and inserting the metal grease filters"). 6. Cancel the C in the display. . Press the button 0. Saturation indicator: C When the activated carbon filter reaches saturation point, an acoustic signal is sounded for 6 seconds after the fan has switched off, and a C appears in the display. The activated carbon filter should be replaced straight away. Replacing the activated carbon filter: . During normal operation (1 to 2 hours per day) the activated carbon filters should be replaced approximately 1 x...

Este manual também é adequado para os modelos :
Hoods - DKE985F/02 (5.3 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias