Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Bosch, Modelo VVA62E450/01

Fabricante : Bosch
Arquivo Tamanho: 1.32 mb
Arquivo Nome :
Língua de Ensino: enfrdenl
Ir para baixar



por este dispositivo também tem outras instruções :
Hoods - VVA62E450/01 (770.34 kb)espt

Facilidade de uso


The bulbs are faulty. For information on changing the bulbs, see the " Replacing Bulbs" section. Replacing bulbs Replacing filament bulbs : Risk of electric shock! When changing the bulbs, the bulb socket contacts are live. Before changing the bulb, unplug the appliance from the mains or switch off the circuit breaker in the fuse box. Important Only use a bulb of the same type and same power (see the bulb holder or rating plate inside the appliance) – to do this, remove the metal mesh grease filter. Replacing halogen bulbs Note: When inserting halogen bulbs, do not touch the glass tube. Use a clean cloth to insert the halogen bulbs. 1. Carefully remove the bulb ring using a suitable tool. 2. Pull out the bulb and replace it with a bulb of the same type. 1. Lift the bulb cover slightly and push towards the outside of the appliance. 2. Unscrew the bulb and replace it with a bulb of the same type. 3. Insert the bulb cover. 4. Insert the mains plug or switch on the fuse again. 3. Insert the bulb cover. 4. Insert the mains plug or switch on the fuse again. After-sales service Our after-sales service is there for you if your appliance needs to be repaired. We will always find the right solution in order to avoid unnecessary visits from a service technician. When calling us, please give the product number ( E no. ) and the production number (FD no.) so that we can provide you with the correct advice. The rating plate with these numbers can be found inside the appliance (remove the metal mesh grease filter to gain access) . You can make a note of the numbers of your appliance and the telephone number of the after-sales service in the space below to save time should it be required. E no. FD no. After- sales serviceO Please be aware that a visit by an after-sales engineer will be charged if a problem turns out to be the result of operator error, even during the warranty period. After- sales contact details for all countries can be found in the attached after-sales service directory. Accessories for circulating- air mode (not included in the delivery) Basic equipment 1 Throw-away filter 2 1 VVZ52V40 2 705431 INSTALLATION INSTRUCTIONS ¦ This appliance is installed on the wall. ¦ Follow the enclosed installation instructions for additional special accessories (e. g. for circulating- air mode). ¦ The surfaces of the appliance are sensitive. Avoid damaging them during installation. : Important safety information Read these instructions carefully. Only thenwill you be able to operate your appliancesafely and correctly. Retain the instructionmanual and installation instructions for future use or for subsequent owners. The appliance can only be used safely if itis correctly installed according to the safetyinstructions. The installer is responsible forensuring that the appliance works perfectlyat its installation location. The width of the extractor hood must correspond at least with the width of thehob. For the installation, observe the currentlyvalid building regulations and theregulations of the local electricity and gassuppliers. Danger of death! Risk of poisoning from flue gases that are drawn back in. Always ensure adequate fresh air in the room if the appliance is being operated inexhaust air mode at the same time as room air- dependent heat-producing appliance isbeing operated. Room air- dependent heat-producing appliances (e.g. gas, oil, wood or coal- operated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system (e.g. a chimney) . In combination with an activated vapour extractor hood, room air is extracted from the kitchen and neighbouring rooms - a partial vacuum is produced if not enough fresh air is supplied. Toxic gases from the chimney or the extraction shaft are sucked back into the living space. ¦ Adequate incoming air must therefore always be ensured. ¦ An incoming/ exhaust air wall box alone will not ensure compliance with the limit. Safe operation is possible only when the partial vacuum in the place where the heat- producing appliance is installed does not exceed 4 Pa ( 0.04 mbar) . This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/ exhaust air wall boxes or by other technical means. In any case, consult your responsible Master Chimney Sweep. He is able to assess the house's entire ventilation setup and will suggest the suitable ventilation measures to you. Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating- air mode. Danger of death! Risk of poisoning from flue gases that are drawn back in. If installing a ventilation system in a room with a heat- producing appliance connected to a chimney/flue, the electricity supply to the hood must be equipped with a suitable safety switch. Risk of fire! Grease deposits ...

Este manual também é adequado para os modelos :
Hoods - VVA92E452/01 (1.32 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias