Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Bosch, Modelo 3MEB60/01

Fabricante : Bosch
Arquivo Tamanho: 1.56 mb
Arquivo Nome :
Língua de Ensino: ende
Ir para baixar



Facilidade de uso


Exhaust air may be discharged in accordance with official and statutory regulations only (e.g. national building regulations). Local authority regulations must be observed when discharging air into smoke or exhaust flues that are not otherwise in use. DWhen the extractor hood is operated in exhaust-air mode simultaneously with a different burner which also makes use of the same chimney (such as gas, oil or coal-fired heaters, continuous-flow heaters, hot-water boilers) care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion. Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa (0.04 mbar). This can be achieved if combustion air can flow through non-lockable openings, e.g. in doors, windows and via the airintake/ exhaust-air wall box or by other technical measures, such as reciprocal interlocking, etc. If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded. Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens. Unrestricted operation is possible if the extractor hood is used in recirculating mode – with activated carbon filter. If the exhaust air is going to be discharged into the open, a telescopic wall box should be fitted into the outside wall. Prior to installation For operating in exhaust-air mode, a one-way flap should be mounted inside the extractor hood unless there is already one fitted in the outlet duct or wall ventilation box. If no one-way flap was enclosed with the hood, it can be obtained from a specialist retailer. Attaching the one-way flap: . Insert the two lugs on the one-way flap into the holes on the air-pipe connector or air outlet and lock into position. Before installing the one-way flap, ensure that the lettering or stamp is on the outside. For optimum extractor hood efficiency: . Short, smooth air exhaust pipe. . As few bends in the pipe as possible. . Diameter of pipe to be as large as possible and no tight bends in pipe. If long, rough exhaust-air pipes, many pipe bends or smaller pipe diameters are used, the air extraction rate will no longer be at an optimum level and there will be an increase in noise. The manufacturer of the extractor hoods accepts no liability for complaints which can be attributed to the design and layout of the pipework. . Round pipes: We recommend Internal diameter: 150 mm. . Flat ducts must have an internal cross- section that equates to that of round pipes. There should be no sharp bends. l150 mm approx. 177 cm2 . If pipes have different diameters: Insert sealing strip. . For exhaust-air mode, ensure that there is an adequate supply of fresh air. Pipe connection . Screw the enclosed air-pipe connector over the air outlet. 150 mm lextraction pipe: . Attach the exhaust-air pipe directly to the air outlet. If a one-way flap has been fitted, conduct a performance test. Prior to installation Circulating-air mode . With activated carbon filter if exhaust-air mode is not possible. 600/700/900/ 1000/1100/1200 The complete installation set can be obtained from specialist outlets. Preparing the wall . The wall must be flat and perpendicular. . Ensure that the wall is capable of providing a firm hold for mounting screws and plugs. Weight in kg: Exhaust air Recirculating air 60 cm 15,0 17,0 70 cm 16,0 18,0 90 cm 17,5 19,5 100 cm 19,0 21,0 110 cm 21,0 23,0 120 cm 23,0 25,0 We reserve the right to construction changes within the context of technical development. Electrical connection WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Fitting a Different Plug: The wires in the mains lead are coloured in accordance with the following code: Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals. Electrical connection This is what you have to do: 1.Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2.Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 3.Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red. The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations. If possible, site the earthed socket directly behind the chimney panelling. Electrical data: Are to be found on the name plate inside the appliance after removal of the filter frame. Before undertaking any repairs, always disconnect the extractor hood from the electricity supply. Length of the connecting cable: 1...

Este manual também é adequado para os modelos :
Hoods - 3MEB90/01 (1.56 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias