|
Facilidade de uso
In any case, consult your responsible Master Chimney Sweep. He is able to assess the house's entire ventilation setup and will suggest the suitable ventilation measures to you. Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating-air mode. Danger of death! Risk of poisoning from flue gases that are drawn back in. If installing a ventilation system in a room with a heat-producing appliance connected to a chimney/flue, the electricity supply to the hood must be equipped with a suitable safety switch. Risk of fire! Grease deposits in the grease filter may catch fire. The specified safety distances must be observed in order to prevent an accumulation of heat. Observe the specifications for your cooking appliance. If gas and electric hobs are operated together, the largest specified distance applies. Only one side of the appliance may be installed directly next to a high-sided unit or a wall. The distance between the appliance and wall or high-sided unit must be at least 50 mm. Risk of injury! ¦ Components inside the appliance may have sharp edges. Wear protective gloves. ¦ The appliance may fall down if it has not been properly fastened in place. All fastening components must be fixed firmly and securely. ¦ The appliance is heavy. To move the appliance, 2 people are required. Use only suitable tools and equipment. Risk of electric shock! Components inside the appliance may have sharp edges. These may damage the connecting cable. Do not kink or pinch the connecting cable during installation. Risk of electric shock! It must always be possible to disconnect the appliance from the electricity supply. The appliance must only be connected to a protective contact socket which has been correctly installed. If the plug is no longer accessible following installation of the appliance, or a fixed connection is required, an all-pole isolating switch must be present on the installation side with a contact gap of at least 3 mm. The fixed connection must only be installed by an electrician. Danger of suffocation! Packaging material is dangerous to children. Never allow children to play with packaging material. General information Exhaust air mode : Risk of death! Risk of poisoning from flue gases that are drawn back in. The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances. If the exhaust air is to be conveyed into a non-functioning smoke or exhaust gas flue, you must obtain the consent of the heating engineer responsible. If the exhaust air is conveyed through the outer wall, a telescopic wall box should be used. Exhaust duct Note: The appliance manufacturer does not assume any warranty for complaints attributable to the pipe section. ¦ The appliance achieves its optimum performance by means of a short, straight exhaust air pipe and as large a pipe diameter as possible. ¦ Because of long rough exhaust air pipes, many of which are pipe bends or have diameters smaller than 150 mm, the optimum extraction performance is not achieved and fan noise is increased. ¦ The pipes or hoses for laying the exhaust duct must consist of non-combustible material. Round pipes An inner diameter of 150 mm, but at least 120 mm, is recommended. Flat ducts The inner cross-section must correspond to the diameter of the round pipes. O 150 mm approx. 177 cm2 O 120 mm approx. 113 cm2 ¦ Flat ducts should have no sharp deflections. ¦ Use sealing strip for deviating pipe diameters. Checking the wall ¦ The wall must be level, vertical and adequately load-bearing. ¦ The depth of the bore holes must be the same length as the screws. The wall plugs must have a secure grip. ¦ The enclosed screws and wall plugs are suitable for solid brickwork. Suitable fasteners must be used for other structures (e.g. plasterboard, porous concrete, poroton bricks). ¦ The max. weight of the extractor hood is 40 kg. Electrical connection : Risk of electric shock! Components inside the appliance may have sharp edges. These may damage the connecting cable. Do not kink or pinch the connecting cable during installation. The required connection data can be found on the rating plate inside the appliance; to do this, remove the metal mesh grease filter. Length of the cable: approx. 1.30 m This appliance complies with the EC interference suppression regulations. : Risk of electric shock! It must always be possible to disconnect the appliance from the electricity supply. The appliance must only be connected to a protective contact socket which has been correctly installed. If the plug is no longer accessible following installation of the appliance, or a fixed connection is required, an all-pole isolating switch must be present on the installation side with a contact gap of at least 3 mm. The fixed connection must only be installed by an electrician. Installation Preparing the installation Caution! Ensure that there ...
Este manual também é adequado para os modelos :Hoods - CD646653/01 (2.1 mb)
Hoods - CD649652/01 (2.1 mb)
Hoods - CD649653/01 (2.1 mb)
Hoods - CD666652/01 (2.1 mb)