Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Bosch, Modelo CD656352/01

Fabricante : Bosch
Arquivo Tamanho: 2.09 mb
Arquivo Nome :
Língua de Ensino: enfrdenl
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


Round pipes An inner diameter of 150 mm, but at least 120 mm, is recommended. Flat ducts The inner cross-section must correspond to the diameter of the round pipes. O 150 mm approx. 177 cm2 O 120 mm approx. 113 cm2 ¦ Flat ducts should have no sharp deflections. ¦ Use sealing strip for deviating pipe diameters. Checking the wall ¦ The wall must be level, vertical and adequately load-bearing. ¦ The depth of the bore holes must be the same length as the screws. The wall plugs must have a secure grip. ¦ The enclosed screws and wall plugs are suitable for solid brickwork. Suitable fasteners must be used for other structures (e.g. plasterboard, porous concrete, poroton bricks). ¦ The max. weight of the extractor hood is 40 kg. Electrical connection : Risk of electric shock! Components inside the appliance may have sharp edges. These may damage the connecting cable. Do not kink or pinch the connecting cable during installation. The required connection data can be found on the rating plate inside the appliance; to do this, remove the metal mesh grease filter. Length of the cable: approx. 1.30 m This appliance complies with the EC interference suppression regulations. : Risk of electric shock! It must always be possible to disconnect the appliance from the electricity supply. The appliance must only be connected to a protective contact socket which has been correctly installed. If the plug is no longer accessible following installation of the appliance, or a fixed connection is required, an all-pole isolating switch must be present on the installation side with a contact gap of at least 3 mm. The fixed connection must only be installed by an electrician. Installation Preparing the installation Caution! Ensure that there are no electric wires, gas or water pipes in the area where holes are to be made. 1. Mark a vertical centre line on the wall from the ceiling to the lower edge of the extractor hood. 2. Mark positions for the screws and the contour of the attachment area. 3. Drill five 8 mm O holes to a depth of 80 mm for the attachments and press in the wall plugs flush with the wall. .................................................................................................... 24 Installation 1. Screw on the fixing bracket for the flue duct. . 2. Screw on brackets for the extractor hood hand-tight, max. 3 Nm.© 3. Screw in threaded pin, leaving it protruding out of the wall by 5 - 9 mm... Attaching and aligning the appliance 1. Initially remove the protective foil from the back of the appliance and, following installation, remove the foil completely. 2. When attaching the appliance, ensure that it engages firmly with the brackets. « 3. Align the appliance horizontally by turning the brackets. If required, the appliance can be moved to the right or left. ¬ Securing the appliance 1. Press the safety caps with the arrow upwards onto the brackets until they engage. ® 2. Screw on the knurled nut and washer firmly. . .... .. .... .. .................. .................. .. .. .. .. .. Removing the safety caps If the safety caps must be removed, use a flat screwdriver. Connecting the pipes Note: If using an aluminium pipe, smooth the connection area beforehand. Exhaust-air pipe O 150 mm (recommended size) Attach the exhaust-air pipe directly to the air-pipe connector and seal. Exhaust-air pipe O 120 mm 1. Attach the reducing connector directly to the air-pipe connector. 2. Attach the exhaust air pipe to the reducing connector. 3. Seal both joints appropriately. Attaching the flue duct : Risk of injury! From sharp edges during installation. Always wear protective gloves while installing the appliance. 1. Separate the flue ducts. To do this, remove the adhesive tape. 2. Remove the protective foil from both flue ducts. 3. Push one flue duct into the other. Notes ¦ To prevent scratches, lay paper over the edges of the lower flue duct to protect the surface. ¦ Slots of the inner flue duct point downwards. 4. Place flue ducts on the appliance. 5. Push the inner flue duct upwards and attach it to the fixing brackets on the left and right. . 6. Press the flue duct downwards until it engages. © 7. Screw the flue duct to the sides of the fixing bracket using two screws. . .......... . Table des matieres NOTICE D'UTILISATION .......................................................... 26 Precautions de securite importantes ............................... 26 Protection de l'environnement .......................................... 28 Modes .................................................................................. 28 Utilisation ............................................................................ 29 Nettoyage et entretien........................................................ 29 Anomalies – que faire ? ..................................................... 31 Service apres-vente ........................................................... 32 NOTICE DE MONTAGE ..............................................................

Este manual também é adequado para os modelos :
Hoods - CD659352/01 (2.09 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias