Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Bosch, Modelo LC98KC552/01

Fabricante : Bosch
Arquivo Tamanho: 1.1 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


Press the Abutton. Setting the brightness Press and hold the Abutton until the desired brightness is reached. Saturation display When the metal mesh grease filters or the activated carbon filter are saturated, a signal sounds for approx. 4 seconds after the fan is switched off. In addition, the corresponding symbol appears in the display: ¦ Metal mesh grease filter:! ¦ Activated carbon filter: " If you have not yet done so, the metal mesh grease filters should be cleaned or the activated carbon filter changed now. For instructions on how to clean the metal mesh grease filters, please refer to the section Cleaning and maintenance. While the saturation displays are flashing, they can be reset. To do this, press the – button. Switching over the display for circulating-air mode For circulating-air mode, the electronic control display must be switched over accordingly: ¦ The extractor hood must be connected and switched off. ¦ Press the # and !buttons at the same time until the ™"display for starter sets for circulating-air mode or ’" display for CleanAir circulating air modules lights up. ¦ Repeatedly press the button combination to switch the electronic control display back to exhaust air mode (! display). Audible signal Switching on the acoustic signal When the fan is switched off, press the # and + at the same time for approx. three seconds. An acknowledgement signal sounds. Switching off the acoustic signal Repeat the "Switching on the acoustic signal" process. Control panel model 2 Control panel Explanation # Fan on/off A Light on/off/dimming -Reduce the fan settings + Increase the fan settings/intensive setting 1, 2 & Boost function (short-term maximum power) x Fan run-on time Setting the fan Switching on the appliance ¦ Press the # button. The fan starts at setting .. ¦ Press the + or - button to change the fan strength. Switching off Press the # button. Intensive setting You can use the intensive setting if there is a large build-up of odours and fumes/vapours. Press the + button when the fan is at setting „. The intensive setting2‚ is activated. Pressing the + button again activates the intensive setting 2 .. After approx. six minutes, the electronics automatically reduce the fan to a lower setting . If you want to end the intensive setting before the preset time expires, press the - button until the required fan setting is reached. Boost function The boost function is a short-term maximum power setting which can be activated in any fan setting. Press the & button. After approx. 20 seconds, the fan switches back to the previously set fan setting. Fan run-on time Press the x button. The fan continues to operate for a further 10 minutes, and switches off automatically after this time. If the lighting is switched on, it remains on. Press the x button to end the fan run-on time early. Lighting The lighting can be switched on and off independently of the fan. Press the A button. Setting the brightness Press and hold the A button until the desired brightness is reached. Saturation display When the metal mesh grease filters or the activated carbon filter are saturated, a signal sounds for approx. 4 seconds after the fan is switched off. In addition, the corresponding symbol appears in the display: ¦ Metal mesh grease filter:! ¦ Activated carbon filter: " If you have not yet done so, the metal mesh grease filters should be cleaned or the activated carbon filter changed now. For instructions on how to clean the metal mesh grease filters, please refer to the section Cleaning and maintenance. While the saturation displays are flashing, they can be reset. To do this, press the x button. Switching over the display for circulating-air mode For circulating-air mode, the electronic control display must be switched over accordingly: ¦ The extractor hood must be connected and switched off. ¦ Press the # and ! buttons at the same time until the ™"display for starter sets for circulating-air mode or ’" display for CleanAir circulating air modules lights up. ¦ Repeatedly press the button combination to switch the electronic control display back to exhaust air mode (! display). Audible signal Switching on the acoustic signal When the fan is switched off, press the # and + at the same time for approx. three seconds. An acknowledgement signal sounds. Switching off the acoustic signal Repeat the "Switching on the acoustic signal" process. Control panel model 3 Control panel Explanation # Fan on/off A Light on/off/dimming -Reduce the fan settings + Increase the fan settings/intensive setting 1, 2 & Boost function (short-term maximum power) ! Automatic mode with fan run-on time Setting the fan Switching on the appliance ¦ Press the # button. The fan starts at setting .. ¦ Press the + or - button to change the fan strength. Switching off Press the # button. Intensive setting You can use the intensive setting if there is a large build-up of odours and fumes/vapours. Press the + button when the fan is at setting „. The intensive se...

Este manual também é adequado para os modelos :
Hoods - LC98KC652B/01 (1.1 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias