Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Carrier, Modelo SANTO 3150-7 KG

Fabricante : Carrier
Arquivo Tamanho: 362.17 kb
Arquivo Nome : 175900en.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


• Ensure there are no obstructions preventing the door from closing properly. Maintenance and Cleaning Before any maintenance or cleaning work is carried out DISCONNECT the appliance from the ELECTRICITY supply. Internal Cleaning 0 1. Press the FROSTMATIC button several hours in advance, in order to build up sufficient chill reserve in the frozen food for the interruption in service. 2. Remove frozen food, wrap it in several layers of newspaper and store it, covered, in a cool place. 3. Switch off refrigerator and freezer and remove plug from the mains, or switch off or turn out the circuit breaker or the fuse. 4. Defrost the freezer compartment (see section: "Defrosting"). 5. Clean the inside and accessories with warm water and bicarbonate of soda (5 ml to 0.5 litre of water). Rinse and dry thoroughly. 1 Warning! • Do not use detergents, abrasive powders, highly perfumed cleaning products, wax polishes or cleaning products containing bleach or alcohol. 6. Regularly check the door seals and wipe clean to ensure they are clean and free from debris. 818 17 59-00/5 Maintenance and Cleaning External Cleaning 0 1. Wash the outer cabinet with warm soapy water. 1 Warning! • Do not use abrasive products • There are sharp edges on the underside of the product so care should be taken when cleaning. 2 Accumulation of dust at the condenser increases energy consumption. For this reason carefully clean the condenser at the back of the appliance once a year with a soft brush or a vacuum cleaner. Replace Light Bulb 3 For safety reasons the interior lighting switches off after 20 minutes when the door is open. It switches on again the next time the door is opened. 1 Warning! Danger of electrical shock! Before replacing the light bulb switch off the appliance and remove the mains plug. Light bulb specifications: 220-240 V, max. 25 W, fitting: E 14 0 1. To switch the appliance off press and hold both ON/OFF buttons until the mains power lights go off. 2. Unplug the mains plug. 3. To change the light bulb, undo the cross head screw and remove the light bulb cover downwards. 4. Change the defective light bulb. 5. Refit the light bulb cover and the cross head screw. 818 17 59-00/5 Something not Working Before contacting your local service force centre, check the following points. Symptom Solution Check there is power at the socket No power to the appliance. Check there is not a power cut by checking the household lights. Check the fuse has not blown. The temperature in the refrigerator/ freezer is too high. Check the ambient temperature is within the appliances operating limits Check the temperature regulator is turned to the correct setting relative to ambient conditions. Water on the floor Water drain hole is blocked, see "Maintenance and Cleaning". Interior illumination does not function. Important: The interior lighting switches off automatically after 20 minutes. Please refer to "Replace Light Bulb " section. The compressor runs continuously Excessive build up of frost. Adjust the thermostat to give correct temperature control. Check that the door is closed. Large quantities of food have recently been placed in the cabinet and/or door is frequently opened. Check that air ventilation is not obstructed. If the door seal is not airtight (probably after changing over the door hinges) apply warm air to the non sealing area using a hair dryer set to a gentle heat. (do not use a fan heater for this purpose). This will make the rubber more supple and allow it to revert to its original shape. Noise Refer to Normal Operating Sounds 818 17 59-00/5 Something not Working Symptom Solution The compressor does not start This is normal, the compressor starts after immediately after changing the a period of time. temperature setting. If after the above checks there is still a fault, call your local AEG Service Force Centre. In-guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown. Please note that proof of purchase is required for in-guarantee service calls. 818 17 59-00/5 Technical Terminology • Refrigerant Liquids that can be used to a generate a cooling effect are known as refrigerants. They have a relatively low boiling-point, indeed so low, that the warmth from the food stored in the fridge or freezer can cause the refrigerant to boil and vaporise. • Refrigerant Circuit Closed circulation system that contains the refrigerant. The refrigerant circuit comprises primarily of an evaporator, a compressor, a condenser and pipe work. • Evaporator The refrigerant is evaporated in the evaporator. Similar to all other liquids, refrigerant requires heat to evaporate. This heat is removed from the interior of the appliance, as a result the interior is cooled. The evaporator is therefore located inside the appliance or placed in foam immediately behind the inner wall and thus not visible. • Compressor The compressor looks like a small drum. I...

Este manual também é adequado para os modelos :
Frigoríficos - SANTO 3150-7 KG (362.17 kb)
Frigoríficos - SANTO 3150-7 KG (362.17 kb)
Frigoríficos - SANTO 3150-7 KG (362.17 kb)
Frigoríficos - SANTO 3150-7 KG (362.17 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias