Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Chicago Electric, Modelo 94533

Fabricante : Chicago Electric
Arquivo Tamanho: 307.2 kb
Arquivo Nome : 47ebef22-61f7-467c-8918-8a42e4926d60.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


All rights reserved. No portion of this instruction sheet or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. For technical questions, please call 1-800-444-3353. SAVE THESE INSTRUCTIONS SAFETY WARNINGS AND PRECAUTIONS Always wear ANSI-approved safety impact eye goggles during setup or use. Maintain a safe working environment. Always keep the work area free of obstructions, grease, oil, trash, and other debris. Do not use this product in areas near flammable chemicals, dust, and vapors. Read and understand all instructions and safety precautions as outlined in the manufacturer’s manual of the battery with which this product will be used. FIRE HAZARD! Never allow the red and black Battery Clamps to touch each other or the same metal object. WARNING! Lead acid batteries generate hydrogen gas during normal operation, and even more gas is generated when the battery is charging. Hydrogen gas is explosive and highly flammable. Never smoke near a charging battery. Plug the Charger into its electrical outlet only after it is connected to the vehicle’s battery. Do not attempt to start a vehicle with the Charger connected to its battery. WARNING! If battery fluid comes in contact with skin, wash with soap and water and rinse with lemon juice and vinegar. If the fluid comes into contact with eyes, flush with water for several minutes and contact a physician immediately. Never burn a battery as it can explode in a fire. Do not attempt to charge a leaking battery. WARNING! People with pacemakers should consult their physician(s) before using this product. Electromagnetic fields in close proximity to a heart pacemaker could cause interference or failure of the pacemaker. In addition, people with pacemakers should adhere to the following: Caution is necessary when near the coil, spark plug wires, or distributor of a running engine. SKU 94533 For technical questions, please call 1-800-444-3353 PAGE OPERATING INSTRUCTIONS To Charge A Battery Using The Battery Clamps: 8312 NOTE: See the last page of this instruction sheet for a complete Parts List and Assembly Diagram. Make sure the transmission of the vehicle is in “PARK” and the emergency brake has been set. Also, turn off the engine of the vehicle prior to connecting the Battery Charger to the battery of the vehicle. Attach the RED/POSITIVE (+) Battery Clamp of the Temporary Connection Cord (8) to the POSITIVE battery terminal of the vehicle. Attach the BLACK/NEGATIVE (–) Battery Clamp of the Temporary Connection Cord (8) to the NEGATIVE battery terminal of the vehicle. Connect the Temporary Connection Cord (8) to the Output Cord (3) of the Battery Charger. Plug the Power Cord (2) of the Battery Charger into the nearest 120 volt, grounded, electrical outlet. The RED (AC Power) light on the Main Unit (1) of the Battery Charger should be illuminated. This light indicates the Main Unit is receiving 120 volt electrical power from the electrical outlet. The YELLOW (Charging) light on the Main Unit (1) of the Battery Charger should be illuminated. This light indicates charging is taking place. The GREEN (Charged) light on the Main Unit (1) of the Battery Charger will illuminate when the vehicles’ battery is fully charged. Once the vehicle’s battery is fully charged, unplug the Power Cord (2) from its 120 volt electrical outlet. Disconnect the RED/POSITIVE (+) Battery Clamp of the Temporary Connection Cord (8) from the POSITIVE battery terminal of the vehicle’s battery. Then disconnect the BLACK/NEGATIVE (–) Battery Clamp from the Temporary Connection Cord (8) from the NEGATIVE battery terminal of the vehicle’s battery. Make sure to store all parts of the Battery Charger in a clean, dry, safe location out of reach of children. To Charge A Battery Using The Ring Connectors: 123456 Make sure the transmission of the vehicle is in “PARK” and the emergency brake has been set. Also, turn off the engine of the vehicle prior to connecting the Battery Charger to the battery of the vehicle. Attach the RED/POSITIVE (+) Ring Connector of the Permanent Connection Cord (4) to the POSITIVE battery terminal of the vehicle. Attach the BLACK/NEGATIVE (–) Ring Connector of the Permanent Connection Cord (4) to the NEGATIVE battery terminal of the vehicle. Unplug the Connection Cord Cap (5) from the Permanent Connection Cord (4). Connect the Permanent Connection Cord (4) to the Output Cord (3) of the Battery Charger. Plug the Power Cord (2) of the Battery Charger into the nearest 120 volt, grounded, electrical outlet. The RED (AC Power) light on the Main Unit (1) of the Battery Charger should be illuminated. This light indicates the Main Unit is receiving 120 volt electrical power from the electrical outlet. The YELLOW (Charging) light on the Main Unit (1) of the Battery Charger should be illuminated. This light indicates charging is taking place. The GREEN (Charged) light on the Main Unit (1) of the Battery Charger wil...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias