Log:
Assessments - , GPA: ( )

Instruções de Operação Philips, Modelo HX6982/10

Fabricante : Philips
Arquivo Tamanho: 675.87 kb
Arquivo Nome :

Língua de Ensino: en

O documento está colocado, por favor, espere
O documento está colocado, por favor, espere


por este dispositivo também tem outras instruções :

Facilidade de uso


Close the door and press the green power on/off button once to select the UV clean cycle. Note:You can only turn on the sanitizer if the door is properly closed. Note:The sanitizer stops if you open the door during the sanitizing cycle. - - - EngliSh 11 Note:The sanitizer cycle runs for 10 minutes and then automatically shuts off. The sanitizer is in operation when the blue light glows through the Philips logo and the UV clean LED flashes slowly. When the sanitizing cycle is complete, the UV clean LED light turns solid green and the sanitizer automatically shuts off. Cleaning Do not clean the brush head, travel charger, charger cover and the UV sanitizer in the dishwasher. Toothbrush handle 1 Remove the brush head and rinse the metal shaft area with warm water. Do not push on the rubber seal on the metal shaft with sharp objects, as this may cause damage. Use a damp cloth to wipe the entire surface of the handle. Brush head 1 Rinse the brush head and bristles after each use. Remove the brush head from the handle and rinse the brush head connection at least once a week with warm water. Charger 1 Unplug the charger. Use a damp cloth to wipe the surface of the charger. Sanitizer (select models) Do not clean the sanitizer when the UV light bulb is hot. For optimal effectiveness, it is recommended to clean your sanitizer weekly. 1 Unplug the sanitizer. Slightly lift the drip tray and pull it out. Rinse the drip tray and wipe it clean with a damp cloth. 3 Clean all reflector surfaces with a damp cloth. ,, 1 EngliSh 4 Remove the protective screen in front of the UV light bulb. To remove the screen, gently lift it up (1) and pull it out (2). Remove the UV light bulb. To remove the light bulb, grasp it and pull it out of the metal clasp. Clean the protective screen and the UV light bulb with a damp cloth. 7 Reinsert the UV light bulb. To reinser t the light bulb, align the bottom of the light bulb with the metal clasp and push the bulb into the clasp. Reinsert the protective screen. To reinser t the screen, align the pegs on the screen with the slots on the reflective surface near the UV light bulb. Then inser t the pegs into the slots and slide down the screen to secure it in the sanitizer. Storage If you are not going to use the product for an extended period of time, unplug it from the electrical outlet, clean it and store it in a cool and dr y place away from direct sunlight.You can use the cord wrap to store the power cord in an organized manner. You can store brush heads on the pegs at the back of the charger. Replacement Brush head Replace Sonicare brush heads ever y 3 months to achieve optimal results. Use only Sonicare ProResults replacement brush heads. UV light bulb Replacement UV bulbs are available through your Sonicare Customer Ser vice Center in Nor th America by calling 1-800-682-7664. Outside Nor th America, contact your local Philips Customer Care Center. Disposal The rechargeable batter y inside your Sonicare cannot be replaced, but is easy to remove for recycling. At the end of product life and prior to disposal, please remove the rechargeable batter y from the handle by following the instructions below. Do not throw away the appliance or the UV light bulb (bulb contains mercur y) with the normal household waste at the end of its life, but hand it in at an official collection point for recycling. By doing this, you help to preser ve the environment. If you have any recycling questions, contact your local waste management office. Removing the rechargeable battery Please note that this process is not reversible. To remove the rechargeable batter y, you need a flat-head (standard) screwdriver. Obser ve basic safety precautions when you follow the - - - - - - - - - EngliSh 13 procedure outlined below. Be sure to protect your eyes, hands, fingers, and the surface on which you work. 1 To deplete the rechargeable battery of any charge, remove the handle from the charger, turn on the Sonicare and let it run until it stops. Repeat this step until you can no longer switch on the Sonicare. Insert a screwdriver into the slot located at the bottom of the handle and turn counterclockwise to release the bottom cap. 3 Hold the handle upside down and push down on the shaft to release the internal components of the handle. 4 Insert the screwdriver under the circuit board, next to the battery connections, and twist to break the connections. Remove the circuit board and pry the battery from the plastic carrier. The rechargeable batter y can now be recycled and the rest of the product discarded appropriately. guarantee and service If you have any questions after reading this manual, feel free to contact our Customer Ser vice Center or visit our website. Customer Ser vice Center 1-800-682-7664 (Nor th America), outside Nor th America contact your local Philips Customer Care Center. Internet information: (Nor th America) or com (outside Nor th America) See separate Philips worldwide guaran...

Este manual também é adequado para os modelos :
Escovas de dentes - HX6942/04 (675.87 kb)
Escovas de dentes - HX6982/03 (675.87 kb)
Escovas de dentes - HX6942/10 (675.87 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias