Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Wolf, Modelo SRT484DG

Fabricante : Wolf
Arquivo Tamanho: 132.07 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


To obtain local dealer information, visit the Locator section of our website, wolfappliance.com. Specifications are subject to change without notice. IMPORTANT NOTE: A minimum 10" (254) riser is required for charbroiler (C) or griddle (G) models installed against a combustible surface. Dimensions in parentheses are in millimeters unless otherwise specified. Planning Information Planning Information 48" (1219) Sealed Burner Rangetops INSTALLATION VENTILATION HOOD 48" (1219) FINISHED ROUGH OPENING WIDTH 30"min (762) TO 36"max (914) TO BOTTOM OF VENTILATION HOOD 36"min (914) COUNTERTOP TO COMBUSTIBLE MATERIALS 44"min (1118) FOR CHARBROILER LOCATION OF GAS AND ELECTRICAL SUPPLY CUT-OUT WITHIN SHADED AREA THROUGH BOTTOM OF PLATFORM 3/4" (19) PLATFORM TOP VIEW OF PLATFORM EG16" (406) 16" (406) 4" (102) BACK WALL 18"min (457) TO COUNTERTOP 6"min (152) TO COMBUSTIBLE MATERIALS (BOTH SIDES) 36" (914) 3/4" (19) PLATFORM 81/2" (216) COOKING SURFACE 71/2" (191) 24" (610) 13" max (330) ISLAND INSTALLATIONS: 12" (305) MINIMUM CLEARANCE FROM BACK OF RANGETOP TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP– 0" (0) TO NON-COMBUSTIBLE MATERIALS DIMENSIONS Rough Opening Width 48" (1219) Rough Opening Height 7 1 / 2 " (191) Rough Opening Depth 24" (610) Location of Electrical and Gas Supply Within shaded area See Installation Instructions shipped with unit for detailed specifications. Dimensions in parentheses are in millimeters unless otherwise specified. Planning Information Planning Information 48" (1219) Sealed Burner Rangetops INSTALLATION INSTALLATION NOTES Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics. IMPORTANT NOTE: Caution must be used in planning the proper installation of the Wolf sealed burner rangetop to avoid any fires or damage to adjacent cabinetry or kitchen equipment. Follow the minimum clearances established in the finished rough opening dimensions as shown in the Installation illustration. The platform for the rangetop must be 3/4" (19) thick and include a cut-out at the right rear for gas supply and electrical connections. The platform must be level to ensure that the cooking surface is level. IMPORTANT NOTE: A minimum 10" (254) riser is required for charbroiler (C) or griddle (G) models installed against a combustible surface. It is recommended that you use a Wolf Pro wall or island ventilation hood or hood liner with the Wolf sealed burner rangetop. Refer to the Pro Ventilation section of our website, wolfappliance.com. The Wolf sealed burner rangetop requires a 110/120 V AC, 50/60 Hz electrical supply to operate the electronic ignition system. The power supply cord is equipped with a 3-prong, grounded plug for protection against shock hazard. The service should have its own 15 amp circuit breaker. Locate electrical and gas supply within the shaded area shown in the Installation illustration. IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. Wolf sealed burner rangetops are designed to operate on natural gas at 5" (12.5 mb) WC (water column) pressure or LP (propane) gas at 10" (25 mb) WC pressure. The minimum line pressure for natural gas is 7" (17.5 mb) WC and 11" (27.4 mb) WC for LP gas. The maximum gas supply pressure to the regulator should never exceed 14" (34.9 mb) WC; .5 psi (3.5 kPa). If local codes permit, a certified, 3' (.9 m) long, 1/2" or 3/4" ID flexible metal appliance connector is recommended for connecting the rangetop to the gas supply line. IMPORTANT NOTE: A separate external gas shut-off valve must be located near the rangetop in an accessible location. Wolf sealed burner rangetops using natural gas will operate up to an altitude of 8,000' (2438 m) without any adjustment. Natural gas and LP gas installations from 8,000' (2438 m) to 11,000' (3353 m) need the high altitude conversion kit. Contact your Wolf dealer for details. To obtain local dealer information, visit the Locator section of our website, wolfappliance. com. You must follow all National Electrical Code and gas regulations. In addition, be aware of local codes and ordinances when installing your services. Refer to the installation instructions shipped with each Wolf product for detailed specifications. Dimensions in parentheses are in millimeters unless otherwise specified. ...

Este manual também é adequado para os modelos :
Greeley - SRT486G (132.07 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias