To override the time delay, push the Max. Temp. Set Point button again. D. Press the ^ ^^ TEMP or Ў ЎЎ TEMP button on the control panel and set maximum spa temperature to 104°F (40°C) or less. E. Wait up to 30 seconds; the SPA ON light will go off and the unit will shut down. To override the time delay, push the Max. Temp. Set Point button again. 4. Reinstall the access door panels. Initial Troubleshooting Only qualified, trained service technicians with appropriate test equipment should service the heater. Remember that all parts of the system affect heater operation. Before starting this troubleshooting procedure, make sure that the pump is running correctly, that there are no blockages in the system, that the valves are correctly set and that the time clock is correctly set and is running. IMPORTANT! READ ME FIRST!! NOTICE: Installing the black 120 volt plug in the control box and on either 120 Volts AC or 240 Volts AC. then connecting the heater to a 240 volt line will destroy the trans2. Remove the covers and check the 12-pin plug in the back of the former, control board, and ignition control module, and will void the control box. The plug must match the voltage in the heater circuit. warranty. If you install the red 240 volt plug and then connect the heater to a 120 volt line, the heater will not operate. 3. If the 12-pin plug is not plugged into the back of the control box, select the correct plug from the bag in the control box Go to chart “HEATER WILL NOT FIRE - A” (Page 24) Go to chart “HEATER WILL NO YES Is green “POOL” or “SPA” LED “on”? Is red “SERVICE SYSTEM” READ THE FOLLOWING CAREFULLY: 1. Check the line voltage to your heater. This heater will operate and plug it in. The BLACK plug is for 120 volts, the RED plug is for 240 volts. Start here for directions to specific Troubleshooting Chart YES LED “on”? NO YESIs red “SERVICE HEATER” LED “on”? NO Turn off power to heater for about 5 seconds, and turn back on. Make sure tempera- ture setting is above water temperature. Wait one minute. Do any diagnostic LED’s on back of board (AGS, AFS, SFS, HLS, PS, or THERMISTOR) come “on” and stay on? NOTICE: Any or all of the diag- nostic LED’s may come “on” momentarily when you turn on the power to the heater. YES NO Are any red diagnos- tic LED’s on back of board (AGS, AFS, SFS, HLS, PS or THERMISTOR) “on” NO Does red “SERVICE HEATER” LED come “on” NO YES NOT FIRE - B” (Page 25) Go to specific safety switch troubleshooting chart (Pages 28 and 29) YES Go to chart ‘HEATER WILL NOT FIRE -C” (Page 26) Verify that water temperature setting is above water temperature reading. If it is, and heater either will not fire or no red LED’s come “on”, replace Control Board. Hazardous voltage. Can shock, burn or kill. Disconnect power before servicing any components. Fire and Explosion hazard. Do not jumper switch terminals to remedy a failed safety switch. WARNINGWARNING 23 Heater Will Not Fire - A Start GO TO Heater should fire on demand for heat. Check Fireman’s Switch circuit connections (time clock, wiring, external controller relay). Remove jumper. Check wiring between Transformer and J7 terminals on Control Board and between J7 and Fireman’s Switch on Terminal Board, check fuse, and restore continuity. Restore power to heater. Replace Transformer. Heater should fire on demand for heat. Replace Control Board. Replace Membrane Pad. Check wiring connections between power supply and Junction Box and between Junction Box and Terminal Board; restore continuity. Check wiring connections between Terminal Board and Transformer primary and restore continuity. Is green “SPA” or “POOL” LED “on” YES NO NO YES YES YES NO NO Depress “POOL” or “SPA” ON button on Membrane Pad. Does “POOL” or “SPA” LED come on? Check for line voltage to heater. Check for 24 VAC at sec- ondary of Transformer. Check for Line Voltage at Transformer primary pins. White connects to Pin 3 on Transformer, Black to Pin 2, Orange to Pin 1. 240V: check Pin1 to Pin 3. 120V: check Pin 2 to Pin 3. Jumper Fireman’s Switch at Terminal Board and depress “POOL” or “SPA” ON button on membrane pad. Does “SPA” or “POOL” LED come “on”? Leaving jumper in place, check for 24 VAC between Fireman’s Switch terminals and ground. Jumper pins 6 and 5 on J6 of Control Board. Does “SPA” LED come on? Jumper pins 6 and 4 on J6 of Control Board. Does “POOL” LED come on? Check for Line Voltage between L1 and L2 terminals on Terminal Board. NO YES NO NO YES YES YES YES YES NO NO YES NO Check that correct 12-pin plug is installed (red is 240V, black is 120V) If plug is not installed: Install correct plug. 240V plug in 120V circuit: Replace with correct plug. 120V plug in 240V circuit: Replace trans- former, control board, and ignition control module (see “HEATER WILL NOT FIRE-C and -D”, Pages 26 and 27). Check fuse and all other 24V components for damage. Remove jumper. Check ribbon cable connection between Membrane Pad and J6 on Control Board. Depress “POOL” or “SPA” On pad again. ...
Este manual também é adequado para os modelos :Piscinas - MASTERTEMP 200K BTU/HR (7.1 mb)
Piscinas - MASTERTEMP 300K BTU/HR (7.1 mb)
Piscinas - MASTERTEMP 250K BTU/HR (7.1 mb)