Log:
Downloads : 69   Arquivo Tamanho: 400 kb   Fabricante : Pentair  
Categoria : Piscinas
@name

Check suction piping and valve glands on any suction gate valves. b. Secure lid on pump strainer pot and make sure lid gasket is in place. c. Check water level to make sure skimmer is not drawing air. 2. Pump will not prime--not enough water. - Remedy: a. Make sure suction lines, pump strainer, and pump volute are full of water. b. Make sure valve on suction line is working and open, (some systems do not have valves). c. Check water level to make sure water is available through skimmer. 3. Pump

Downloads : 1   Arquivo Tamanho: 264 kb   Fabricante : Pentair  
Categoria : Piscinas
@name

This innovative hydraulic design moves water more efficiently and more quietly than competitive pumps. Under typical operating conditions, WhisperFlo offers the highest water flow of any high performance pump-yet with the lowest electrical consumption. And, WhisperFlo is designed to be a tireless workhorse. Its engineered thermoplastic housing withstands extreme heat and resists corrosion. The commercial grade motor frame has a rust-proof, stainless steel motor shaft and sealed bearings that ne

Downloads : 110   Arquivo Tamanho: 1 mb   Fabricante : Pentair  
Categoria : Piscinas
@name

The Smart pHTM is a Class 1 product for protection against electric shock and a Type 1 product with regards to disconnection of the control circuits. Observe the following safety precautions: . Do not permit anyone untrained or under the age of 18 to use this product. . Unit must be properly connected to earth ground. . Never apply power when front panel is not secured in the closed position. . Never service unit with power applied, always turn OFF main circuit breaker to unit and all equipment

Downloads : 10   Arquivo Tamanho: 7 mb   Fabricante : Pentair  
Categoria : Piscinas
@name

You can schedule start and stop times for each feature. All Features are operated using Flow control. The Feature mode and Filter mode are run simultaneously. The three types of features are; Features 1 & 2, Features 3 -9 and M.O. Flo: Features 1 and 2 Feature 1 and Feature 2 run for a pre-defined duration with a specifically set flow. If Feature 1 or Feature 2 buttons are pressed, all other Features are temporarily deactivated. Feature 1 or Feature 2 cannot be used in Backwash Mode. Features 1

Downloads : 8   Arquivo Tamanho: 898 kb   Fabricante : Pentair  
Categoria : Piscinas
@name

Pltd. 5 1 35-4894 Pump Tri Pod Base Plastic 4 1 35-3775 Seal Bracket -Plastic 3 2 35-4294 Screw, Cap 3/8 -16 x 1 1/4” Cad. Pltd. 2 1 35-3750 Shaft Extension -Bronze 1 Motor Item Qty. Part No. NAME OR DESCRIPTION LIST OF MATERIAL OR PARTS LIST 7 SPECIAL INSTRUCTION FOR TWO SPEED ENERGY MASTER HYDROPUMP: The performance of this pump will be the same at high speed as the same model single speed pump, both hydraulically and prime wise. At low speed the pump will produce one half the flow and the pre

Downloads : 7   Arquivo Tamanho: 898 kb   Fabricante : Pentair  
Categoria : Piscinas
@name

Make sure pool water is midway of skimmer opening. NOT PRIME: 2. Make sure strainer basket is not clogged. 3. Make sure strainer basket is positioned properly! 4. Tighten lid down snugly. 5. Make sure strainer pot is full of water. 6. TIghten all fittings and seal all joints on suction side. 7. Clean skimmer and pump strainer baskets. 8. Remove pump lid and check for clogging. 9. Open all valves in return and suction lines. 10. Remove and replace pump seal if needed. 11. Check voltage at pump to

Downloads : 24   Arquivo Tamanho: 122 kb   Fabricante : Pentair  
Categoria : Piscinas
@name

The result is a filtration and circulation system engineered to provide superior performance, longevity and lifetime value. Key features include: • Tagelus filters include design features that continuously flatten and level the sand inside the tank, a key to more effective and efficient filtration, and longer run times between backwashing. • Easy does it. Tagelus features the handy six-position Hi-Flow™ valve with manual air relief valve and a sight glass to make inspections, routine mainten

Downloads : 5   Arquivo Tamanho: 256 kb   Fabricante : Pentair  
Categoria : Piscinas
@name

Protected by one or more of the following U.S. Patents and all corresponding foreign counterparts: U.S. Pat. No. 4,995,523, 5,190,651, 5,753,071 and 6,036,853. Pentair Water Pool and Spa, Inc. © 2008 Pentair Water Pool and Spa, Inc. All rights reserved. This document is subject to change without notice. 1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000 Trademarks and Disclaimers: System 3® and Pentair Water Pool and Spa® are re

Downloads : 26   Arquivo Tamanho: 1019 kb   Fabricante : Pentair  
Categoria : Piscinas
@name

Read all servicing instructions before working on the pump. WARNING — DO NOT open the strainer pot if pump fails to prime or if pump has been operating without water in the strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water. Opening the pump may cause serious personal injury. In order to avoid the possibility of personal injury, make sure the suction and discharge valves are open and strainer pot temperature is cool

Downloads : 29   Arquivo Tamanho: 1 mb   Fabricante : Pentair  
Categoria : Piscinas
@name

Note: Before installing this product, read and follow all warning notices and instructions starting on page ii. Electrical Requirements and Wiring When pump is mounted permanently within 5 ft. of the inside walls of a swimming pool, you MUST use a No. 8 AWG or larger conductor to connect to bonding conductor lug. Wiring Installation WARNING — Risk of electrical shock or electrocution. This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accord





categorias