Log:
Assessments - 3, GPA: 4.7 ( )

Instruções de Operação Sony, Modelo ICD-B10

Fabricante : Sony
Arquivo Tamanho: 623.86 kb
Arquivo Nome : 3230616111.pdf
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :
Ditado - ICD-B10 (574.85 kb)es
Ditado - ICD-B10 (577.08 kb)de

Facilidade de uso


Maximum recording time With the ICD-B10, you can record for up to 63 minutes in SP (standard play) mode and 168 minutes in LP (long play) mode. If you record messages in a mixture of SP and LP modes, the recordable time varies from 63 to 168 minutes. With the ICD-B15, you can record for up to 127 minutes in SP (standard play) mode and 339 minutes in LP (long play) mode. If you record messages in a mixture of SP and LP modes, the recordable time varies from 127 to 339 minutes. The unit is factory-set to SP mode. To change the recording mode, see page 36. You can check the remaining amount of recording time by selecting the remaining recording time display mode. See page 34. Remaining memory indication During recording, the remaining memory indicator decreases one by one. flashing When the remaining time of recording reaches 5 minutes, the last one of the indication flashes. When the remaining time of recording reaches 1 minute, the selected display mode (page 34) and “REMAIN” will flash one after the other in the display window. When the memory is full, recording automatically stops and “FULL” will flash in the display window with an alarm sound. To continue recording, first erase some of the messages (page 19). 12GB Various Ways of Recording Various Ways of Recording — Advanced VOR function When the VOR (voice operated recording) function is set to ON (page 36), recording starts when the recorder detects sound and stops when no sound is heard. Note VOR function is affected by the sound around you. Set the microphone sensitivity (SENS) to either HI (high) or LO (low) (see page 36). If recording is not satisfactory after you have changed the microphone sensitivity, or for important recording, set VOR to OFF. Recording with an external microphone or from other equipment Connect a plug-in-power type microphone or other equipment to the MIC (PLUG IN POWER) jack. When you connect an external microphone, the built-in microphone is automatically cut off. When a plug-in-power type microphone is connected, power is automatically supplied to the microphone from the IC recorder. Adding a recording To add a recording to a previously recorded message or to add an overwrite recording during playback, see pages 21 and 22. Basic Operations 13GB Playing Back Messages Playing Back Messages Select the folder. Select the message number. 1 2 Current folder Press FOLDER repeatedly to display the folder you wish to play back. Press . or > to display the desired message number. .: for smaller message number >: for larger message number Selected message number Counter display* * The display selected with the DISPLAY button (page 34) appears. 14GB Start playback. Start playback. 1 3 Press NxPLAY/STOP. OPR indicator (lights in green during playback.) 2 Turn VOL to adjust Counter the volume. display (or the selected display mode) After playing back one message, the unit stops at the beginning of the next message. When the last message on a folder has been played back, the unit stops at the beginning of the last message. For private listening Connect an earphone or headphones (not supplied) to the EAR jack. The built- in speaker will be automatically disconnected. If you plug in headphones, you will get monaural output from both left and right channels. To stop playback To Do this stop at the beginning of Press xSTOP. the current message stop at the current position Press NxPLAY/STOP. (Playback Pause function)* To resume playback from that point, press NxPLAY/STOP again. * You can also pause playback by pressing XPAUSE instead of NxPLAY/ STOP. The OPR indicator will flash in green. After an hour, the unit goes into the stop mode at the current position. Playing back all messages in a folder continuously — Continuous Play See page 36. Continued 15GB Basic Operations Playing Back Messages (continued) Other operations Playing Back Messages (continued) Other operations o Do this go back to the beginning Press . once.*** of the current message** skip to the next message** Press > once.*** go back to previous Press . or > repeatedly.*** messages/skip to (During stop mode, keep the button succeeding messages pressed to skip the messages continuously.) play back rapidly or Set PLAY SPEED to FAST or SLOW. slowly The messages will be played back about 30% faster or 15% slower than normal. play messages with Set PLAY SPEED to NORMAL. normal speed ** If you have set a bookmark on the message, the unit stops at the bookmark. *** These operations are for when EASY-S is set to OFF. For operations when EASY-S is set to ON, see page 17. Various Ways of Playback Playing back a message repeatedly — Repeat Play During playback, press NxPLAY/STOP for more than one second. “ “ will be displayed and the selected message will be played back repeatedly. To resume normal playback, press NxPLAY/STOP again. To stop playback, press xSTOP. Playing the beginning of each message — Scanning Play During stop mode, press NxPLAY/STOP for more than one second. “SCAN” will ...

Este manual também é adequado para os modelos :
Ditado - ICD-B15 (623.86 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias