Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação PYLE Audio, Modelo PT502

Fabricante : PYLE Audio
Arquivo Tamanho: 438.43 kb
Arquivo Nome : 0c028828-f1c5-4bb5-b2d5-0455904937a6.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


• Always wear proper fitting clothing and other safety equipment when using this tool. HAZARD RISK OF CUT OR BURNS WHAT COULD HAPPEN HOW TO PREVENT IT • Tools which cut, shear, drill, staple, punch, chisel, etc. are capable of causing serious injury. • Keep the working part of the tool away from hands and body. . 4- ENG SPECIFICATIONS Maximum Torque 500 ft./lbs Blows Per Minute 1,000 Maximum Working Pressure 90 PSI Air Inlet 1/4” NPT Recommended Hose Size 3/8” I.D. Air Consumption @ 90 PSI 4.2 SCFM ASSEMBLY Accessories Required IMPORTANT: Line pressure or hose inside diameter should be increased to compensate for unusually long air hoses (over 25 feet). Minimum hose diameter should be 3/8” I.D. and fittings should have 1/4” NPT thread. OPERATION Operation Before each use: . Drain water from air compressor tank and condensation from air lines. See air compressor’s operators manual. Disconnect the tool from the air supply before lubricating or changing sockets. . Lubricate tool, see “Maintenance” section in this manual. Impact wrench sockets and accessories must be used with this tool. Do not use hand sockets and accessories. . Select the required impact socket. This tool has a 1/2" square drive, use 1/2” deep sockets. Use 1/2” extensions only when needed. Air Inlet Trigger 1/2” Square Drive . Connect tool to air hose of recommended size. NOTE: The use of a quick connect set makes connecting easier. IMPORTANT: The use of air filters and air line lubricators is recommended. To use: . Turn air compressor on and allow air tank to fill. . Set the air compressor’s regulator to 90 PSI. This tool operates at a maximum 90 PSI pressure. . Set torque regulator, see chart, to set the desired setting to avoid over tightening. IMPORTANT: These torque values can vary depending on the size of the air compressor and the cubic feet of air (SCFM) the air compressor delivers. . Place tool in forward or reverse position. Place in “F” position for forward or “R” position for reverse. . Depress the trigger to operate tool. . Release trigger to stop tool. . Always disconnect air supply when changing sockets. . When job is complete, turn the air compressor off and store as described in the air compressor operator manual. 5- ENG . #1 approximately 200-275 ft./lbs. Torque #2 approximately 275-350 ft./lbs. Torque #3 approximately 350-425 ft./lbs. Torque #4 approximately 425-500 ft./lbs. Torque Line desired torque # up with indent MAINTENANCE Lubrication Air tools require lubrication throughout the life of the tool. The air motor and bearing uses compressed air to power the tool. Because moisture in compressed air will rust the air motor, you must lubricate the motor daily. An inline oiler is recommended. To lubricate the air motor manually: Disconnect the tool from the air supply holding it so the air inlet faces up. Depress the trigger and place one to two drops of air tool oil in the air inlet Depressing the trigger helps circulate oil in the motor. NOTE: Use SAE #10 weight oil if air tool oil is not available. Connect the tool to an air source, cover the exhaust end with a towel and run for a few seconds. Any excess oil in the motor is immediately expelled from the exhaust port. Always direct exhaust port away from people or objects. Failure to lubricate the tool at the air inlet will void your warranty. . 6- ENG 7- ENG REPAIR PARTS 1A 21 19 49 48 39 44 45 43A 13 11 9 32 8 29 (6) 2 Ref No. Part No. Description Qty 1a D25494 Handle Grip 1 2 u Throttle Valve Spring 1 8 u O-Ring 1 9 u Air Valve 1 11 u O-Ring 1 13 u O-Ring 1 19 + Trigger Pin 1 21 + Trigger 1 29 u Rotor Blade 6 32 u End Plate Gasket 1 39 u Hammer Case Gasket 1 43a u Standard Anvil 1 44 u Socket Retainer 1 45 u Retainer O-Ring 1 48 + / u Cap 1 49 + / u Screw 1 + Only available in Trigger Repair Kit D25489 u Only available in Tune-Up Kit D26759 NOTE: Parts not listed are not serviceable. LIMITED WARRANTY PORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressure washers, and generators, which have the following warranty periods: 3 YEARS - Limited warranty on 2-stage oil-free air compressor pumps that operate at 1725 RPM. 2 YEARS -Limited warranty on oil-lubricated air compressor pumps. 1 YEAR -Limited warranty on all other air compressor components. 2 YEARS -Limited warranty on electric generator alternators. 1 YEAR - Limited warranty on other generator components. 2 YEARS -Limited warranty on pneumatic air tools as described in Porter-Cable general catalog. 1 YEAR -Limited warranty on pressure washers used in consumer applications (i.e. personal residential household usage only). 90 DAY -Pressure washers used for commercial applications (income producing) and service parts. 1 YEAR -Limited warranty on all accessories. Porter-Cable will repair or replace, at Porter-Cable's option,...

Este manual também é adequado para os modelos :
Brocas e shuropopverty - PT502 (438.43 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias