|
Facilidade de uso
Raise the squeegee tool off the floor, then unsnap the Center Latch (A) on the squeegee tool. 2 Remove the Tension Straps (B). 3 Slip the rear blade off the alignment pins. 4 The squeegee blade has 4 working edges. Turn the blade so a clean, undamaged edge points toward the front of the machine. Replace the blade if all 4 edges are nicked, torn or worn to a large radius. 5 Install the blade, following the steps in reverse order and adjust the squeegee tilt. To Reverse or Replace the Front Squeegee Blade... 1 Raise the squeegee tool off the floor, then loosen the (2) Thumb Nuts (C) on top of the squeegee and remove the squeegee tool from the mount. 2 Remove both rear Tension Straps first. 3 Remove all the wing nuts that hold the front blade in place, then remove tension strap and blade. 4 The squeegee blade has 4 working edges. Turn the blade so a clean, undamaged edge points toward the front of the machine. Replace the blade if all 4 edges are nicked, torn or worn to a large radius. 5 Install the blade, following the steps in reverse order and adjust the squeegee tilt. SQUEEGEE ADJUSTMENT There is just one squeegee tool adjustment possible, angle. Adjusting the Squeegee Angle Adjust the squeegee angle whenever a blade is reversed or replaced, or if the squeegee is not wiping the floor dry. 1 Park the machine on a flat, even surface and lower the squeegee. Then drive the machine forward enough to have the squeegee blades fold over to the rear. 2 Loosen the Lock Wing Nut (D) (hand tightened). This secures the squeegee mount angle from easily vibrating out of adjustment. 3 Turn the Adjustment Knob (E) to tilt the tool forward or backwards, until the rear squeegee wiping blade touches the floor evenly across its entire width. 4 Re-tighten by hand the Lock Wing Nut (D). Adhancer™ R28-C, R32-C / BR 800S TRIO EDS™ - 56041647 - A-15 A-16 / ENGLISH SIDE SKIRT MAINTENANCE The side skirts' function is to channel the waste water to the squeegee, helping contain the water within the machines cleaning path. During normal use the blades will wear in time. The operator will notice a small amount of water leaking out underneath the side skirts. A height adjustment can easily be made to lower the blades so that all the water can be picked up by the squeegee. To replace the scrub system side skirt(s) ... 1 See Figure 5. Loosen the (2) side skirt Retainer Knobs (A) (2 per side) and pull the Skirt Assemblies (B) off from the scrub deck. 2 Remove the (C) Screws and Nuts, remove the Skirts and replace. 3 Replace the blades as a set if they are nicked, torn or worn beyond their ability to be adjusted. 4 Reinstall the skirt housing assemblies onto the machine and adjust the blade for proper contact to the floor when the brush deck is placed in the scrub position. SIDE SKIRT HEIGHT ADJUSTMENT 1 The side skirt housing knob retainer screw studs have leveling Adjuster Collars (D), that are to be raised or lowered to compensate for blade wear. 2 To adjust, remove the Skirt Assemblies (B) from the Scrub Deck (E) to access the Adjuster Collars (D). Adjustment Tip: The skirts Retainer Knobs (A) can be loosened with skirts left on and the Adjuster Collars (D) rotated by reaching under the skirt housing. 3 Turn the Adjuster Collars (D) (Up or Down) to where the blades just fold over enough when scrubbing that all the waste water is contained inside the skirting. Note: Make small adjustments to obtain good blade wiping. Do not lower the blades too much to where they fold over excessively and cause unneeded blade wear. FIGURE 5 A-16 - 56041647 - Adhancer™ R28-C, R32-C / BR 800S TRIO EDS™ revised 2/07 ENGLISH / A-17 GENERAL MACHINE TROUBLESHOOTING Problem Possible Cause Remedy Poor water pick-up Worn or torn squeegee blades Reverse or replace Squeegee out of adjustment Adjust so blades touch floor evenly across entire width Recovery tank full Empty recovery tank Recovery tank drain hose leak Secure drain hose cap or replace Recovery tank cover gasket leak Replace gasket / Seat cover properly Debris caught in squeegee Clean squeegee tool Vacuum hose clogged Remove debris Using too much solution Adjust solution control valves Foam filter cover not seated Seat cover properly Poor scrubbing performance Worn brush Rotate or replace brushes Wrong brush type Consult Nilfisk-Advance Wrong cleaning chemical Consult Nilfisk-Advance Moving machine too fast Slow down Not using enough solution Adjust solution flow rate to high flow Inadequate solution flow or no solution Solution tank empty Fill solution tank Solution lines, valves, filter or trough clogged Flush lines, trough and clean solution filter Solution valve not open Open solution valve Solution solenoid valve Clean or replace valve Machine does not run Emergency stop switch tripped Reconnect battery connectors Operator seat safety switch Check for open circuit and replace Main system controller Check error...
Este manual também é adequado para os modelos :Gazonouborschiki - 56316025 (R32-C) (2.41 mb)
Gazonouborschiki - 56316038 (BR 800S TRIO EDS) (2.41 mb)