Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Nilfisk-Advance America, Modelo 56316025 (R32-C)

Fabricante : Nilfisk-Advance America
Arquivo Tamanho: 2.41 mb
Arquivo Nome : 28ea7cbb-0b6c-46ef-a4f6-d0a6a2309925.pdf
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


Sulfuric acid in batteries can cause severe injury if allowed to contact the skin or eyes. Explosive hydrogen gas is vented from inside the batteries through openings in the battery caps. This gas can be ignited by any electrical arc, spark or flame. When Servicing Batteries... • Remove all jewelry. • Do not smoke. • Wear safety glasses, a rubber apron and rubber gloves. • Work in a well-ventilated area. • Do not allow tools to touch more than one battery terminal at a time. • ALWAYS disconnect the negative (ground) cable first when replacing batteries to prevent sparks. • ALWAYS connect the negative cable last when installing batteries. A CAUTION! Electrical components in this machine can be severely damaged if the batteries are not installed and connected properly. Batteries should be installed by Nilfisk-Advance or by a qualified electrician. 1 Turn the Key Switch (J) off (O) and remove the key. Then swing open the Battery Compartment Cover (16). 2 Using (2) people and an appropriate lifting strap, carefully lift the batteries into the compartment tray exactly as shown. Refer to decal 56015168 battery cable layout. 3 See Figure 1. Install battery cables as shown and tighten the nuts on the battery terminals. 4 Install the battery boots and secure tightly to the battery cables with the supplied tie straps. 5 Connect the battery pack connector to the machine connector (22) and close the battery compartment cover. 305A/H - 20HR - RATE Adhancer™ R28-C, R32-C / BR 800S TRIO EDS™ - 56041647 - A-7 A-8 / ENGLISH INSTALL THE BRUSHES A CAUTION! Turn the key switch off (O) and remove the key, before changing the brushes, and before opening any access panels. 1 Make sure the Key Switch (J) is off (O). See Figure 2. To access the brushes, remove both side skirt assemblies. Note: The skirts are held in place by a two large Knobs, loosen these knobs and slide the skirt assemblies off of the Scrub Deck. 2 Loosen the black knobs (one on each side) on top of the idler assemblies and remove the idler assemblies. Slide the brush into the housing, lift slightly, push and turn until it seats. Re-install the idler assemblies, then reinstall both side skirt assemblies. FIGURE 2 A-8 - 56041647 - Adhancer™ R28-C, R32-C / BR 800S TRIO EDS™ ENGLISH / A-9 INSTALL THE SQUEEGEE 1 Make sure the Squeegee (19) is up (O) and the Key Switch (J) is off (O). Hold the squeegee tool so that the curved ends point forward, then slide the squeegee tool onto the Mount (A) (see Figure 3). 2 Hand tighten the Thumb Nuts (B) and then connect the vacuum hose to the Squeegee Tube (C) (vacuum hose should loop to the right). FILL THE SOLUTION TANK Read the cleaning chemical label and figure the proper amount of chemical to mix for a tank that holds 30 US gallons (113 liters). Open the Solution Tank Cover (2), then fill the tank 1/3 full of water, add the cleaning chemical, then fill the tank to 7.62cm (3 inches) from the top of the tank opening (fill to bottom of the wall in tank opening). NOTE: AXP/EDS machines can either be used conventionally with detergent mixed in the tank or the detergent dispensing system can be used. When using the AXP/EDS detergent dispensing do not mix detergent in the tank, plain water should be used. A CAUTION ! Use only low-foaming, non-flammable liquid detergents intended for automatic scrubber machine applications. Water temperature should not exceed 130 degrees Fahrenheit (54.4 degrees Celsius). FIGURE 3 Adhancer™ R28-C, R32-C / BR 800S TRIO EDS™ - 56041647 - A-9 A-10 / ENGLISH DETERGENT SYSTEM PREPARATION AND USE COMMON INSTRUCTIONS: The system should be purged of previous detergent when switching to a different detergent. SERVICE NOTE: Move machine over floor drain before purging because a small amount of detergent will be dispensed in the process. To Purge When Changing Chemicals: 1 Disconnect and remove the detergent cartridge. 2 Turn the Key Switch (J) ON and press the Detergent ON/OFF Switch (S) and the Flow Rate Switch (T) down for at least 3 seconds. NOTE: Once activated the Flow Rate Indicator (U) will begin to flash and will automatically shut off after 10 seconds. Normally one purge cycle is adequate to purge the system. To Purge Weekly: 1 Disconnect and remove the detergent cartridge. Install and connect a Cartridge filled with clean water 2 Turn the Key Switch (J) ON and press the Detergent ON/OFF Switch (S) and the Flow Rate Switch (T) down for at least 3 seconds. NOTE: Once activated the Flow Rate Indicator (U) will begin to flash and will automatically shut off after 10 seconds. Normally one purge cycle is adequate to purge the system. The Detergent Box (AA) has a Detergent Level Viewing Slot (BB) for keeping track of how much detergent is remaining in the cartridge. When the detergent level is nearing the bottom of this slot it is time to refill or replace the cartridge. General Use: The detergent (AXP/EDS) system is turned on when the Key Switch (J) is turne...

Este manual também é adequado para os modelos :
Gazonouborschiki - 56316026 (R32-C) (2.41 mb)
Gazonouborschiki - 56316038 (BR 800S TRIO EDS) (2.41 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias