Log:
Assessments - 3, GPA: 4.7 ( )

Instruções de Operação Empire Comfort Systems, Modelo UNVENTED GAS LOG HEATER VFDR18LBP-1

Fabricante : Empire Comfort Systems
Arquivo Tamanho: 3.61 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


See page 11 for Installing as a Vented Appliance. • Raise the mantel to the proper height. • Remove the mantel. Floor Clearance (Figure 6) If installing heater at floor level, the minimum distance to combustibles is “0” inches. Figure 4 If your installation does not meet the above clearances, you must proceed to one of the following steps: • Use a hood. • Operate the heater with flue damper open. See page 11 for Installing as a Vented Appliance. • Raise the mantel to the proper height. • Remove the mantel. Figure 6 23099-1-0707 Page 9 Page 10 23099-1-0707 FOR MASONRY BUILT FIREPLACES FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING COMBUSTION PRODUCTS FROM DECORATIVE APPLIANCES FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES * Height is from hearth to top of chimney and the minimum height is 6 feet. ** Chart shows minimum opening (sq. in.) for given height and input rate. • Turn off gas supply to fireplace or firebox. • Have the fireplace floor and chimney professionally cleaned to remove ashes, soot, creosote or other obstructions. Have this cleaning performed annually after installation. • Seal any fresh air vents or ash clean-out doors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney flue damper. Install and operate the appliance as directed in this manual. FOR FACTORY BUILT FIREPLACES FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING COMBUSTION PRODUCTS FROM DECORATIVE APPLIANCES FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES * Height is from hearth to top of chimney and the minimum height is 10 feet. ** Chart shows minimum opening (sq. in.) for given height and input rate. Do not attach combustible material to the mantel of your fireplace. This is a fire hazard. Figure 7 No greeting card, stockings or ornamentation of any type should be placed on or attached to the fireplace. This is a heating appliance. The flow of heat can ignite combustibles. Figure 8 Appliance Input Rate (BTU/hr) 20 30 40 Chimney Height* (ft) Minimum Opening** (sq. in.) 10 11.3 16.6 22.1 15 8.6 12.6 17.3 20 7.5 10.8 14.5 25 6.6 9.6 12.6 30 6.2 9.1 11.3 35 5.7 8.0 10.8 40 5.3 7.5 10.2 Appliance Input Rate (BTU/hr) 20 30 40 Chimney Height* (ft) Minimum Opening** (sq. in.) 6 17.6 25.7 33.8 8 16.5 23.7 31.2 10 15.1 21.7 28.7 15 14.1 19.9 26.1 20 12.9 18.5 23.7 30 12.2 16.9 21.6 COMBUSTIBLE MATERIAL FIREPLACE PREPARATION 23099-1-0707 Page 11 Notice (Damper Clamp Installation) When installing your log set as a vented installation the damper clamp must be used. When installing your log set as a vent-free installation the damper clamp can be used to eliminate the potential for odors when burning the logs for the first time. Installing Damper Clamp (Figure 9) Remove all ashes or other debris from the fireplace. If the fireplace is equipped with an ash dump be sure to seal the door with furnace cement or high temperature silicone. Be sure to check the damper for proper operation and verify that the flue passageway is open. Place the clamp over the lip of the damper and tighten the hold down bolt until the clamp is securely attached to the damper. This will prevent the damper from accidentally closing. Manual and millivolt controlled gas logs may be installed as a vented decorative log set in compliance with ANSI Z21.60 and National Fuel Gas Code. When the gas logs are operated with the damper open, non-combustible material and minimum mantel requirements do not apply. • Turn off the gas supply to the fireplace or firebox. • Seal any fresh air vents and/or ash clean-out doors located on the floor or wall of the fireplace. If left unsealed, drafting may cause pilot outage or sooting. Use a heat resistant sealant. Do not seal the chimney flue damper. Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. You must secure the gas log heater to the fireplace floor. If not, the entire unit may move when you adjust the controls. Movement of unit may cause shifting of the gas logs which leads to sooting and improper burning. Grate movement could cause a gas leak. Special care is required if you are installing the unit into a sunken fireplace. You must raise the fireplace floor to allow access to gas log controls. This will insure adequate air flow and guard against sooting. Raise the fireplace floor using noncombustible materials. Assembly Procedure: (Figure 10) 1. Center the gas log unit in the fireplace or firebox. Make certain the front feet of the grate sit inside the front edge of the fireplace or firebox. 2. An anchor hole is provided in the two bottom side members of the grate frame. After centering the grate correctly, mark the hole positions on the fireplace/firebox floor. Drill two (2) 5/32" diameter holes approximately 1-1/2" deep for masonry screws or 1/8" hole for sheet metal screws. 3. Anchor the grate to the fireplace/firebox flo...

Este manual também é adequado para os modelos :
Aquecedores a gás - UNVENTED GAS LOG HEATER VFDM18LBN-1 (3.61 mb)
Aquecedores a gás - UNVENTED GAS LOG HEATER VFDM24LBN-1 (3.61 mb)
Aquecedores a gás - UNVENTED GAS LOG HEATER VFDM30LBN-1 (3.61 mb)
Aquecedores a gás - UNVENTED GAS LOG HEATER VFDR18LB10N-1 (3.61 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias