|
Facilidade de uso
Remote Switch 51842 51842 22. Air Shutter LP (10,000 and 15,000) 20000129 -23. Remote Switch Kit (Not Shown) 53875 53875 24. Piezo Ignitor Replacement kit (Not Shown) 20000062 -25. O.S.A. Assy 3547900 3547900 26. Ember Package --10000550 27. Glass w/Gasket --55686 28. Gasket Glass --57317 29. Frame Window --57937 30. CO Catalyst Filter --55629 31. Bracket CO Catalyst Holder --56255 32a. Valve NOVA - Natural --55463 32b. Valve NOVA - LP --55462 Contact CFM Corporation for questions concerning prices and policies covering replacement parts. Parts may be ordered through your Majestic Fireplaces distributor or dealer. You will need the following information when ordering replacement parts: 1. The heater model number. 2. The serial number. 3. A description of the part. Should you need additional information beyond what your dealer can furnish, contact: CFM Corporation 410 Admiral Blvd. Mississauga, Ontario Canada L5T 2N6 Attn: Technical Service Model and serial numbers are listed on the rating plate (located on right side of combustion chamber). Record your model and serial numbers here for future reference: Model # ____________________________ Serial # ____________________________ 18 20002211 UVS33/36 Vent-Free Heaters Optional Accessories Fan Kits FK12 Fan Kit This auxiliary fan system increases the efficiency of the circulation of the heating air. The FK12 Fan Assembly is a fixed speed fan system and does not allow for variable speed control. It does not use the speed control unit or the heat sensor used in the FK24 kit. Specifications 115 Volts / 60 Hz / .75 Amps. Installation The fan assembly is supplied fully wired eliminating the need for a licensed electrician to carry out the installation. 1. Open the lower louvre assembly. Maneuver the fan & bracket assembly around the gas valve and lines to locate the unit against the back wall of the appliance, resting on the base. 2. With the protective cover removed from the self-adhesive 'Velcro' strips apply mild pressure to the fan & bracket unit to secure the strips to the metal panels. No further securing is required. 3. Power to the fan can be supplied by plugging the supply lead into a conveniently located wall socket or by using a hard-wired EB-1 connector box. FK24 Fan Kit This auxiliary fan system increases the efficiency of the circulation of the heating air. The FK24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the circuit. Specifications 115 Volt / 60Hz / .75 Amps Installation The fan assembly and other components are supplied fully wired eliminating the need for a licensed electrician to carry out the installation. If hard wiring the fan in using Method B (following) we strongly recommend the use of a licensed electrician. 1. Open the lower louvre assembly. Maneuver the fan & bracket assembly around the gas valve and lines to locate the unit onto the screw studs on the back of the fireplace. 2. Install the thermal sensor under the bottom of the firebox, locating it over the two 10 mm studs and secure it with nuts. 3. Locate the fan speed control unit. This can be fitted behind the lower louvre assembly or located remotely in a conveniently located wall mounted electrical box. Remote location of the speed control will require suitable extension of the component wiring. 4. The power supply may be connected in two ways: Method A Route the 6’ lead fitted to the unit to a conveniently located wall socket. Method B The EB-1 receptacle box (Pt. # ZA1200) may be hard wired into the house supply. The fan lead is then plugged into the EB-1 box Electrical Connection The EB-1 electrical junction box is available for use with the fan kits. Remote Controls Optional remote control units are available to control different functions of the appliance. Model Function(s) Controlled RC1 ON/OFF RC2 ON/OFF and Temperature IMTFK Wall mounted thermostat control Outside Air Termination The AK-1 completes the connection from outside air kit to out-of-doors. (Does not include 4" flex duct.) Ceramic Brick Liner Ceramic panels are available to line the firebox area. Model 33BDVCR Decorative Bay Screen Kit The 33BSTK Bay Window Screen Kit is available to place on the front of the unit. 20002211 19 UVS33/36 Vent-Free Heaters Decorative Frame Trims A selection of decorative frame trim kits are available for mounting around the outside of the appliance to enhance its visual effect on the room. Installation instructions for each decorative frame trim are included with the frame trim kit. Unit Kit Model UVS33 DV33GTP, DV33GTA, DV33GTS, DV33TKP, DV33TKMP, DV33TKMA, DV33TKMS, DV33TKMB, DV33TKWP, DV33CBTK UVS36 DV36GTP, DV36GTA, DV36TKP, DV36TKA, DV36KMP, DV36KMA DV36KWP, DV36KWA Glass/Catalyst Kit Only glass approved by CFM Corporation should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass. • Do not operate appliance with g...
Este manual também é adequado para os modelos :Aquecedores a gás - UVS33RN (2.22 mb)
Aquecedores a gás - UVS33RP (2.22 mb)
Aquecedores a gás - UVS36RN (2.22 mb)