|
por este dispositivo também tem outras instruções :
Facilidade de uso
Inspection Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage. The packaging is recyclable; save it for reuse or dispose of it properly. Placement Install the UPS in a protected area that is free of excessive dust and has adequate air flow. Do not operate the UPS where the temperature and humidity is outside the specified limits. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the warranty. Connect to Utility Check the Site Wiring Fault Indicator Location: Top right corner of UPS back panel. Caution: If the site wiring fault indicator lights, get a qualified electrician to correct the building wiring. Connect the Loads Plug the loads into the output connectors on the rear of the UPS. To use the UPS as a master “On/Off” switch, make sure that all of the loads are switched “On”. Caution: Do not connect a laser printer to the Battery Backup Outlets. Battery Backup Outlets: These UPS outlets provide battery power and surge protection to equipment when utility voltage is outside acceptable limits. Data sensitive equipment such as a computer, monitor, or external drive are connected to these outlets. Connect Telephone / Network Surge Suppression (Optional) Connect a single line telephone or a 10Base-T/ 100Base-Tx network cable into the RJ-45/RJ-11 telephone/network surge protection “IN” jack on the back of the UPS. Connect from the “OUT” jack with telephone cable (supplied) or network cabling (not supplied) to a fax modem or network port. Connect Computer Interface Port (Optional, BP1100) PowerChute® plus power management software is included with this UPS. Connect the supplied interface cable to the 9-pin computer interface port on the back panel of the UPS. Connect to the computer. See software documentation for installation instructions. Charge the battery The UPS charges its battery whenever it is connected to utility power. The battery will charge fully during the first 4 hours of normal operation. Do not expect full runtime during this initial charge period. Operating Instructions Switch “On” — Switch “Off” With the UPS plugged in, press and release the On/Off/Test button to supply power to the loads. The UPS loads are immediately powered while the UPS performs a self-test. Press and release the button again to turn “Off” power to the loads. It may be convenient to use the UPS as a master “On/Off” switch for the protected equipment. The on-line LED illuminates when the UPS is supplying utility power to the battery backup loads. Self-test The UPS performs a self-test automatically when turned “On”, and every two weeks thereafter (by default). Automatic self-test eliminates the need for periodic manual self-tests. During the self-test, the UPS briefly operates the loads on-battery. If the UPS passes the self-test, it returns to on-line operation. If the UPS fails the self-test it immediately returns to on-line operation and lights the replace battery LED. The loads are not affected by a failed test. Recharge the battery overnight and perform the self-test again. If the replace battery LED is still "On”, replace the battery using the Replacing the Battery procedure. On-Battery During on-battery operation, the onbattery LED illuminates and the UPS sounds an audible alarm consisting of 4 beeps every 30 seconds. The alarm stops when the UPS returns to on-line operation. Low Battery When the UPS is operating on-battery and the energy reserve of the battery runs low, the UPS beeps continuously until the UPS shuts down from battery exhaustion or returns to on-line operation. Overload When loads exceed the UPS’s capacity, the overload LED illuminates and the UPS emits a sustained tone. The alarm remains “On” until the overload is removed. Disconnect nonessential load equipment from the battery backup outlets, to eliminate the overload. If the overload is severe, the input circuit breaker may trip (the resettable center ...
Este manual também é adequado para os modelos :Fonte de alimentação e fonte de alimentação - 1000, 1100, 1400 (180.98 kb)
Fonte de alimentação e fonte de alimentação - 1100 (180.98 kb)