Instruções de Operação American Power Conversion, Modelo 1000, 1100, 1400

Fabricante : American Power Conversion
Arquivo Tamanho: 180.98 kb
Arquivo Nome : ASTE-6Z7V7Q_R0_EN.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Disconnect nonessential load equipment from the UPS to eliminate the overload and press the plunger back in to restart the UPS. If there is AC power and the circuit breaker does not trip during overload, the loads are still powered. If the circuit breaker trips or the UPS attempts to transfer to battery, the loads’ power will be shut “Off”. Turn the UPS “Off” then back “On” to repower the loads. Replace Battery If the battery fails a self-test, the UPS emits short beeps for one minute and the replace battery LED illuminates. The UPS repeats the alarm every five hours. Perform the self-test procedure to confirm replace battery conditions. The alarm stops when the battery passes the self-test. Shutdown Mode If there is no power, the host connected to the computer interface port can command the UPS to shut down. This is normally done to preserve battery capacity after a controlled shutdown of the protected system. In shutdown mode the UPS stops supplying power to the load. The online and overload LED indicators flash alternately or, if the UPS has shutdown due to a low battery, the UPS will beep once every 4 seconds for approximately 16 seconds. When line power is restored, the UPS will return to on-line operation. Cold Start Note: Cold start is not a normal operating condition. When the UPS is “Off” and there is no utility power, it is possible to cold start the UPS to power the loads from the UPS’s battery. • Press and hold the On/Off/Test button until the UPS begins beeping. • Release the On/Off/Test button during the beeping to start the UPS. APC, Back-UPS Pro, and PowerChute are registered trademarks of American Power Conversion Corp. Copyright © 2002 Storage Storage conditions Store the UPS covered and upright in a cool, dry location, with its battery fully charged. Before storing, charge the UPS for at least 4 hours. Extended storage At -15 to +30 °C (+5 to +86 °F), charge the UPS’s battery every 6 months At +30 to +45 °C (+86 to +113 °F), charge the UPS’s battery every 3 months. Repplaacciingg the BBatttteryy TTrroouubblleesshhoooottiinngg This UPS has an easy to replace hot-swappable battery. Battery replacement is a safe procedure, isolated from electrical hazards. You may leave the UPS and loads on for the following procedure. See your dealer or call the number in this manual for information on replacement battery kits. Note: Once the battery is disconnected, the loads are not protected from power outages. 1. Grasp the top of the front cover and tilt it out and down. 2. Unhook the bottom of the cover from the chassis and lift it upward to expose the battery door. Be careful not to strain the ribbon cable. Do not touch the exposed printed circuit board. 3. Fold the front cover on top of the UPS as shown. 4. Use a flat-blade screwdriver or a coin to remove the two battery door screws and open the door. 5. Grasp the tab and gently pull the battery out of the UPS. 6. Disconnect the battery leads. • For the 1000 through 1100 VA models, loosen the connectors by gently wiggling them while pulling straight back from the battery connector. 1000/1100 VA • For the 1400 VA model, pull the two gray couplers apart to disconnect the battery. 7. Connect the battery leads to the new battery. Note: Small sparks at the battery connectors are normal during 1400 VA connection. • For the 1000 through 1100 VA models, connect the red wire to the positive (+) terminal and the black wire to the negative (–) terminal. • For the 1400 VA model, connect the gray battery coupler to the UPS’s coupler. 8. Slide the battery into the UPS. 9. Close the battery door, replace the battery compartment screws, and replace the front cover. 10. Dispose of the old battery properly at an appropriate recycling facility or return it to the supplier in the packing material for the new battery. See the new battery instructions for more information. Warranty Problem Possible Cause Solution UPS will not turn “On”. On/Off/Test button not pushed. Press the On/Off/Test button to power the UPS and the loads. UPS input circuit breaker tripped. Reduce the load on the UPS by unplugging equipment and reset the circuit breaker by pressing the plunger back in. UPS will not turn “On” or “Off”. Computer interface problem. Disconnect the computer interface. If the UPS now works normally, check the interface cable and the attached computer. UPS operates on-battery even though normal line voltage is thought to exist. UPS's input circuit breaker tripped. Reduce the load on the UPS by unplugging equipment and reset the circuit breaker by pushing the plunger back in. UPS beeps occasionally. Normal UPS operation. None. The UPS is protecting the load. UPS does not provide expected back up time. The UPS's battery is weak due to recent outage or is near the end of its service life. Charge t...

Este manual também é adequado para os modelos :
Fonte de alimentação e fonte de alimentação - 1100 (180.98 kb)
Fonte de alimentação e fonte de alimentação - 1400 (180.98 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias