* When storing, ALWAYS lower the telescopic pole to its lowest level. This will make it easier to store and reduce the risk of any accidental tipping over of the heater. Maintenance Your Infrared Heating System is virtually maintenance free! A minute to wipe down exposed surfaces is all it takes to maintain your heater. * Head unit and shield: Use a non-abrasive cleaner and a soft cloth to wipe off debris and dirt from the exposed surfaces. NEVER spray liquids or cleaners into the housing area where the halogen lamp is located. Do not try to disassemble of clean the inner cavity where the halogen lamp is located. For any maintenance on the head unit, please call the toll free customer service hotline. * Telescopic pole and curved arm components: These can easily be wiped clean using a non-abrasive cleaner and a soft cloth. * Base with wheel assembly: Use non-abrasive cleaner and a soft cloth. Any scratches, chips or rust spots can be touched up using an exterior matte finish black paint. 10 Halogen Lamp Replacement Contact the toll free customer hotline to order approved replacement lamps and parts. Use ONLY approved original equipment and replacement halogen lamps to ensure safe, proper and maximum output operation of your heater. NOTE: Do NOT touch the new halogen lamp with your bare fingers. Oils from your hand could reduce the life of the lamp by causing a heat spot. We recommend using clean cotton or plastic gloves to handle the lamp. A clean paper towel will also work. MAKE SURE THE HEATER IS TURNED OFF AND DISCONNECTED FROM THE ELECTRICAL OUTLET BEFORE YOU BEGIN!!!! TO REPLACE THE HALOGEN LAMP: 1. Be sure the heater is unplugged from the wall outlet. Remove the head unit assembly from the telescopic pole. 2. Remove 8 screws from each end of the head unit and pull off end plates (#2). Note the placement of the 2 small sheet metal screws on each end plate. Also note end plate side with beveled holes faces outward when re-assembled. 3. Pull out and remove the left and right front air vent panels and protective wire grill (#3). Note the position of end clips on vent panel. They must be aligned as close to the end connectors of lamp tube as possible when re-assembled. Pull or push into place as needed. DO NOT allow metal parts to touch the actual lamp tube when re-assembled. 4. Gently pull out entire old lamp assembly from the clips at the terminal connection ends (#4 & 5). Slide and lift the connection ends out from the friction clips by gently pushing apart the clips. Unscrew wire leads from terminal. Remove entire old lamp assembly. 5. Using gloves, gently re-insert connection ends of the NEW lamp assembly into the friction clips (#4). Pull apart the clips slightly and gently push the connectors into place. Do not allow the metal clips to touch the lamp tube. The clips should be about at the center point of the end connectors. 6. Re-install the safety grill (fits along grooves in housing body), then re-insert the vent panels by gently pushing the end clips into housing body. Align clip ends close to the lamp end connectors and push into place. Re-attach end plates making sure the side with beveled holes faces out. 11 Troubleshooting Problem Unit fails to turn on. Solution Check electrical plug connection at wall outlet for a complete, snug fit. Check to make sure the “On/Off” switch located on tilt switch is pulled OUT or in the “On” position. Check GFI and reset circuit breaker if needed. If unit is plugged into a wall outlet wired to an On/Off switch, make sure switch is in On Position. Reset safety tilt switch. Unplug unit from wall outlet and re-position on flat, level surface. Plug heater back into outlet. Damaged halogen bulb. Call customer service hotline. Telescopic pole slips down. Tighten black tension knobs on clamp collars. Telescopic pole is unsteady. Tighten screws on support collar at base. Telescopic pole will not adjust. Electrical cord may be kinked. Gently pull end of cord until taut. Head unit is loose or unsteady. Tighten screws on curved upper arm mounting bracket. Head unit is hard to adjust. Loosen connecting bolts/nuts at adjustment bracket. Smoke appears from head unit. Unplug IMMEDIATELY and call customer service hotline. Weak output from halogen lamp. Life span of lamp has been reached or damaged lamp. Call customer service hotline for assistance. NOTE: This product comes with a limited one year warranty. After the warranty period, you may purchase replacement bulbs from at the lowest cost available. 12 Distributed By: Well Traveled Living Web: 716 S 8th Street Email: cservice@welltraveled.net Amelia Island, FL 32034 Toll Free: 866.WTL.SUPP 1 YEAR LIMITED WARRANTY – Customers in the Continental US All components are warranted for a period of 1 year after date of purchase by the original owner against defects in materials and workmanship under normal use. This warranty does NOT cover normal wear and weathering, assembly and/or maintenance ...
Este manual também é adequado para os modelos :Eléctrico - 02117 (580.57 kb)
Eléctrico - 02678 (580.57 kb)