|
Facilidade de uso
Both smoke and odor will dissipate after approximately 30 minutes. The heater should not produce thick black smoke. Note: The burner maybe be noisy when initially turned on. To eliminate excessive noise from the burner, turn the control knob to the “LOW” position, then turn the knob to the level of heat desired. Warning : White smoke may appear around the radiant head during the first minutes of the initial firing. When heater is ON: Emitter screen will become bright red due to intense heat. The color is more visible at night. Burner will display tongues of blue flame. These flames should not be yellow or produce thick black smoke, indicating an obstruction of airflow through the burners. If the flame is very small, this indicates the supply pressure is not enough. Relighting the heater: 1) Turn the control knob to “OFF” position. 2) Wait five (5) minutes before attempting to relight pilot. 3) Repeat steps beginning with step 2 on page 12. Before leaving the heater unattended: 1) Turn the control knob to “OFF” position and turn LPG cylinder to “OFF” position. 2) Never leave the patio heater unattended while in use. Shut down instructions: 1) Push in and turn control knob clockwise to “OFF” position. 2) Turn LPG cylinder valve clockwise to “OFF” position when heater is not in use. NOTE: After use, some discoloration of the emitter screen is normal. If you suspect gas leakage: 1) Turn the control knob to “OFF” position. 2) Turn LPG cylinder valve to “OFF” position. 3) Wait 5 minutes to allow gas to dissipate. 4) If odor continues, immediately call gas supplier. DO NOT use the heater. Warning: Heater will be hot after use. Handle with extreme care until completely cooled. - 14 LOCATION OF HEATER WHILE IN USE LOCATION OF HEATER WHILE IN USE CAUTION: WHEN CERTAIN MATERIALS OR ITEMS ARE LEFT UNDER THIS HEATER WHILE IN USE THEY WILL BE SUBJECT TO RADIANT HEAT AND COULD BE SERIOUSLY DAMAGED. This heater is to be used for the heating of outdoor patios, decks, spas, pool, and open working areas. This heater is for OUTDOOR USE ONLY. Always make sure that adequate fresh air ventilation is provided and follow the spacing tolerances shown in the picture below. The minimum clearances must be maintained at all times. This heater must be placed on level, firm ground. Never operate in an explosive atmosphere. Keep away from areas where gasoline or other flammable liquids or vapors are stored or used. - 15 MAINTENANCE MAINTENANCE WARNING FOR YOUR SAFETY: ALLOW HEATER TO COMPLETELY COOL BEFORE MOVING. CLEANING AND MAINTENANCE To enjoy years of outstanding performance from your Heater, make sure you perform the following maintenance on a regular basis: 1. Keep exterior surfaces clean. Use warm soapy water for cleaning. Never use flammable or corrosive cleaning agents. While cleaning your heater, be sure to keep the area around the burner and pilot assembly dry at all times. If the gas control is exposed to water in any way, DO NOT try to use it--it must be replaced. 2. Keep the heater area free and clean from combustib...
Este manual também é adequado para os modelos :Eléctrico - 01337 (1.45 mb)
Eléctrico - 60789 (1.45 mb)
Eléctrico - 60790 (1.45 mb)
Eléctrico - PH-09S (1.45 mb)