Log:
Assessments - 1, GPA: 3 ( )

Instruções de Operação Well Traveled Living, Modelo 60789

Fabricante : Well Traveled Living
Arquivo Tamanho: 1.45 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Ensure that there is no obstruction to air ventilation. Be sure all gas connections are tight and there are no leaks Be sure the access panel is clear of debris. Be sure any component removed during assembly or servicing is replaced and fastened prior to starting. - 11 OPERATION OPERATION Before Lighting: Heater should be thoroughly inspected before each use. Have a qualified service person inspect the heater at least annually. If relighting a hot heater, always wait at least 5 minutes. This heater has been tested for quality assurance LIGHTING INSTRUCTIONS TO TURN ON THE HEATER. 1. Turn the control knob “OFF”. 2. Slowly open the gas cylinder valve fully. 3. Press and turn the control knob to “HI” position ( counter-clockwise 90°). 4. Check for flame at the burner. If burner does not light immediately, turn control knob to “OFF” position and repeat from Step 2. Allow 30 seconds between ignition attempts for gas to dissipate. Several attempts may be necessary. 5. Once the burner is lit, keep control knob depressed for 15 seconds. 6. For lowest heat, push in and turn the control knob to “LOW.” For highest heat, push in and turn the control knob to “HI.” Note: If the pilot flame does not light or it goes out, repeat Step 3 above. WARNING FOR YOUR SAFETY NOTE: If at any time you are · If a new tank has just been connected, please allow unable to light burner at least one minute or more for the air in the gas and smell gas, wait 5 minutes to allow gas to pipeline to purge out through the pilot hole. dissipate before · When lighting the pilot flame make sure that the attempting to light Variable control knob is continuously depressed while heater. If after 1 pressing the igniter button. Variable control knob can minute , you are be released after the pilot flame has been lit unable to light the for 20~30 seconds. burner, wait 5 minutes · Pilot flame can be watched and checked from the and allow flammable peephole located on the base of burner. vapors to dissipate ·If the pilot flame does not light or it goes out, repeat before attempting to light heater again. Step 3. If the burner flame goes out accidentally or it is blown out by wind, turn off the heater and wait at least 5 minutes or more to let the gas dissipate before relighting to avoid possible gas explosion. Repeat steps 2 to 4. ·WARNING: Failure to follow this lighting procedure may result in flame roll out beyond the emitter grid. - 12 OPERATION OPERATION TO TURN OFF THE HEATER. 1. Press and turn the control knob to “OFF” position. 2. Turn off the valve on the LPG cylinder and disconnect the cylinder from the heater. - 13 OPERATION OPERATION CAUTION: Avoid inhaling fumes emitted from the heater’s first use. Smoke and odor from the burning of oils used in manufacturing will appear. Both smoke and odor will dissipate after approximately 30 minutes. The heater should not produce thick black smoke. Note: The burner maybe be noisy when initially turned on. To eliminate excessive noise from the burner, turn the control knob to the “LOW” position, the...

Este manual também é adequado para os modelos :
Eléctrico - 01337 (1.45 mb)
Eléctrico - 60790 (1.45 mb)
Eléctrico - PH-09S (1.45 mb)
Eléctrico - PH-09SS (1.45 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias