Instruções de Operação Monessen Hearth, Modelo CSVF20SPV

Fabricante : Monessen Hearth
Arquivo Tamanho: 2.28 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


or high pressure natural gas (1 to 2 PSI system) (Resistant to sulfur compounds) • Piping which complies with local codes • Manual shutoff valve • Sediment trap (recommended) • Tee joint • Pipe wrench or appropriate wrench set • Screwdrivers 58D56002 PRODUCT SPECIFICATIONS NATURAL GAS NOTE: An external regulator is required to reduce supply pressure to a maximum of 101/2" w.c. on Natural Gas systems operating at higher pressure. MILLIVOLT PRESSURE Regulator Pressure Setting: 3.5" w.c. Pilot Regulator: 3.5" w.c. Gas Inlet Pressure: Max. 10 1/2" w. c. Min. 5" w.c. Model Number Type Gas Rate Max. BTU/Hr Min. BTU/Hr CSVF20SNV(G-EBL-ES-EMB) CSVF30SNV(G-EBL-ES-EMB) Milli-Volt Milli-Volt 10,000 32,000 6,000 20,000 PROPANE / LPG Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c. MILLIVOLT PRESSURE Regulator Pressure Setting: 10" w.c. Gas Inlet Pressure: Maximum 13" w.c. Minimum 11" w.c. Model Number Type Gas Rate Max. BTU/Hr Min. BTU/Hr CSVF20SPV(G-EBL-ES-EMB) CSVF30SPV(G-EBL-ES-EMB) Milli-Volt Milli-Volt 10,000 32,000 6,000 26,000 IGNITION CONTROLS Piezo ignitor allows ignition of the pilot without the use of matches. Milli-Volt control has four (4) positions: OFF -All gas to the burner is shut off at the valve. IGN -Valve position to light/maintain a standing pilot. ON -Valve position to turn burners ON/OFF with remote switch/thermostat. LOW/HI -Variable position to control flame height (heat output). Both front and rear burners are in operation to provide realistic glow and yellow flame. PILOT/ODS The gas log heater is fitted with a specially designed safety pilot (ODS assembly) light which senses the amount of oxygen available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level. The pilot can only be relit when adequate fresh air is available. THERMAL GENERATOR The millivolt gas log pilot is fitted with a millivolt thermopile generator to provide power for remote activation. 58D6002 GENERAL INSTALLATION INFORMATION WARNING Do not install the heater … • Where curtains, furniture, clothing, or other flammable objects are less than 42" from the front of the heater. • In high traffic areas. • In windy or drafty areas. CODES Adhere to all local codes or, in their absence, the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223.1 or NFPA54 which can be obtained from… American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 or National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269 ADEQUATE COMBUSTION AND VENTILATION AIR This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. The National Fuel Gas Code, (ANSI Z223.1/NFPA54), defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 BTU per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 BTU per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space. UNUSUALLY TIGHT CONSTRUCTION IS DEFINED AS CONSTRUCTION WHERE… a) walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of 1 perm (6 x 1011 kg per pa-sec-m2) or less with openings gasketed or sealed; b) weather stripping has been added on openable windows and doors, and c) caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. 58D56002 GENERAL INSTALLATION INFORMATION ONOFFL2L1WHCounter Cast Iron Stove Figure 3 - Example of a Large Room with 1/2 Wall Divider The following formula can be used to determine the maximum heater rating per the definition of unconfined space: BTU/Hr = (L1 + L2) Ft x (W) Ft x (H) Ft x 1000 50 Consider two connecting rooms with an open area between, with the following dimensions: L1 = 151/2 Ft., L2 = 12 Ft., W = 12 Ft., H = 8 Ft. BTU/Hr = (151/2 + 12) x (12) x (8) x 1000 = 52800 BTU/Hr 50 If there were a door between the two rooms the calculation would be based only on the room with the heater. BTU/Hr = (151/2) x (12) x (8) x 1000 = 29760 BTU/Hr 50 WARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, NFPA54, Section 5.3 or applicable local codes. 10 58D6002 CLEARANCES / HEIGHT REQUIREMENTS WARNING The dimensions shown ...

Este manual também é adequado para os modelos :
Eléctrico - CSVF20SNV (2.28 mb)
Eléctrico - CSVF30SNV (2.28 mb)
Eléctrico - CSVF30SPV (2.28 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias