Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Superior, Modelo MILLIVOLT SDVPF-N-B

Fabricante : Superior
Arquivo Tamanho: 4.88 mb
Arquivo Nome : 700037M_F_SDV-ST-PF_II.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The nailing flange itself can directly contact framing. Floor Nailing Tabs - Secure the fireplace to the floor as shown in Figure 10. Figure 10 - Nailing Flanges Remove these screws and use them when installing nailing flanges. Nailing Flanges Turn nailing tabs down and secure to floor with 8d nails or other appropriate fasteners on both sides of appliance which do not have viewing glass panels. SDVST Shown (SDVPF - No nailing flanges on end with glass panel) Detailed Installation Steps The appliance is shipped with all gas controls and components installed and pre-wired. 1. Remove the shipping carton. Remove the shipping pad, exposing the front glass door. 2. Open the two latches (located under the firebox floor) securing the glass door. Remove the door by tilting it outward at the bottom and lifting it up. Set the door aside protecting it from inadvertent damage. See Removing Glass Panels on Page 31. 2. Remove the top louvered panel and locate the pressure relief plates. 3. Lift the pressure relief plates and remove the cardboard from beneath each plate (be careful not to damage the white gasket). See Figure 9. * NOTE: INSTALLATION DIAGRAMS AND INSTRUCTIONS SHOW THE FRONT OF THE APPLIANCE AS THE SIDE WHICH HAS VALVE ACCESS, EXCEPT WHERE NOTED. WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. AVERTISSEMENT Risque de dommages ou de blessures si les pieces ne sont pas installees conformement a ces schemas et ou si des pieces autres que celles specifiquement approuvees avec cet appareil sont utilisees. Figure 9 REMOVE CARDBOARD BEFORE USING REMOVE CARDBOARD BEFORE USING Pressure Relief Plates Remove Cardboard Before Using Appliance FIREPLACE SPECIFICATIONS - MODEL SDVST (SEE-THROUGH ) • Inches (millimeters) Fireplace Framing SPECIFICATIONS • Minimum Framing Stud Size is 2 x 4 • See side views of fireplace below for Specifications Natural & Propane 37,500 gas line inlet location options. Gas BTU Input (MV Low 30,000) **25-1/4(641) 10-1/2(267) 12-1/8(308) 5-1/8(130) 12-1/8(308) 26-3/4(648) 5-1/8(130) Vent Center - Top Vent with one 90 degree elbow Vent Center- Side Vent (no elbows) Dimension A Secure Vent 47-1/8 (1197) Secure Flex 48-3/4 (1238) A v 11-3/8 4-1/2" Inner Co-axial DV Vent Size 7-1/2" Outer NOTES • Annual Fuel Utilization Efficiency Diagrams, illustrations and photographs are not to scale – consult installation instructions. Product designs, materials, dimensions, specifications, colors and prices are subject to change or discontinuance without notice. Appliance has a factory-installed vent seal cap (see Figures 14 and 15 on Page 13) in each flue outlet. *41-1/2 (1054) PRODUCT REFERENCE INFORMATION u Cat. Model Ship Ship. No. Wt. Volume H4633 SDVST 282 lbs 52W x 27D x 441/ 2H (36.2 cu.ft). 48-1/2(1108) (679) (267) (289) 7 (178) 5-1/8 (130) 12-1/8 (308) 10-1/2 22-3/4(578) 6-1/4 (159) A 7 (178) 5-1/8 (130) 12-1/8 (308) 26-3/4 Vent Framing - Top Vent With One 90. Elbow Vent Framing - Rear Vent With No Elbows Gas Line Center of gas line is 3 in. (76 mm) up from floor. Gas Line • This dimension can be reduced to 41 inches (1041 mm). This results in 0 in. (0 mm) clearance between framing and unit framing spacers. (The 41-1/2 in. dimension permits easier fireplace installation, if unit is installed after framing is erected). SDVST EFFICIENCIES • This dimension based on 5/8" drywall. For 1/2" drywall use 25-1/2" (648 mm). The finished dimension should be 26-1/2" (673 mm). See also, Side Vent Seal Cap note below. 61% (NG) 62 % (LP) Vertical Venting Through the Ceiling: Frame ceiling opening -Use a plumb line from the ceiling above the appliance to locate center of the vertical run. Cut and/or frame an opening, 72 % (NG) 10-1/2" x 10-1/2" (267 mm x 267 mm) inside dimensions, about this center mark (see Figure 18 on Page 15). Steady State 73 % (LP) • AFUE Figure 11 68 % (NG) 68 % (LP) 6-7/8 (175) 10-1/4 10-1/2 (260) 12 (305) 12 (305) 10 (254) (63.5) 3 (76) FLUE (Top or Side) (267) FLUE (Top or Side) GAS INLET ELECTRICAL INLETS GAS INLET 40-1/8 (1019) (16) (89) 3 (76) ELECTRICAL INLETS FRAMING SPACERS (Top and Both Sides) 24 (610) FINISH WALL BRACKET (Front and back edge of unit top) 1/2(13) 3-1/2 3-1/2 (89) ELECTRICAL INLETS(940) 37 41 (1041) 4 (102) (13) (1197) 47-1/8 (873) 34-3/8 (610) 24 (63.5) Detail fo Finish 1/2 Stepped to Accept Drywall (all 4 corners) Wall Bracket 2-1/2 2-1/2 (13)1/25/8 Provide additional space for Side Vent Seal Cap if installing against a solid wall. Louvered Control Compartment DoorLeft Side View Front View Right Side View Top View NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. FIREPLACE SPECIFICATIONS - MODEL SDVPF (PENINSULA VIEW) SPECIFICATIONS Natural & Propane 37,500 (MV Low 30,000) 4-1/2" Inner Gas BTU Input Co-axial DV Vent Size 7-1/2" Outer NOTES • Annual Fuel Utilization Efficiency Diagrams, illustrations and photographs are not t...

Este manual também é adequado para os modelos :
Lareiras - MILLIVOLT SDVPF-N-B (4.88 mb)
Lareiras - MILLIVOLT SDVPF-N-B (4.88 mb)
Lareiras - MILLIVOLT SDVPF-N-B (4.88 mb)
Lareiras - MILLIVOLT SDVPF-N-B (4.88 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias