If wires are not connected as shown the switch will not work. 2. Route the 25 ft. wire through openings provided on the sides of the burner system to a convenient location to mount your switch. 3. Connect one bare wire end to each of the terminals of the GWMS2 wall switch. 4. Install the wall switch and cover in the wall. IMPORTANT: Do not use any other wire than that provided with the GWMS2 wall switch kit. Do not exceed 15 ft. of distance from the valve connection. Using wire of higher gage or turns or exceeding the minimum distance will increase resistance at the control valve causing unreliable performance of the fireplace controls. BlueVariableFan SwitchFan Switch(N.O.) GreenWhiteOn110/115 V.A.C. BlowerMotorBlack Off12Black Figure 40 - Blower Wiring Diagram for Thermostat-Controlled Models DO NOTCONNECTREDREPLACE FACTORY WIRING WITH 105°CEQUIVALENT OR HIGHER RATINGTHERMOSTAT WIRE 18 GA. RED/WHITEEXTERNAL WIRING USE ONLY CLASS 2WHITETH/TPTPTHWALL SWITCHTO 120VTHERMOPILEPILOTBURNERIGNITORLINEPILOT GASOFFPILOTONPILOT SAFETY VALVEMAIN GASINCOMINGSUPPLY To Wall Switch Accessory Figure 41 - Millivolt Ignition Wiring Diagram Figure 43 - Connecting Wall Switch to Control Valve Installing Optional Wireless hand-held REMOTE CONTROL for millivolt Egnition - HRC100 and HRC200 Series NOTICE: Use only alkaline batteries (not included). Installing Remote Receiver 1. Open bottom louver and locate the switch bracket on the right 2. Locate the battery clip mounted on the back of the receiver. Slide a 9-volt alkaline battery (not included) through the clip 3. Attach the terminal wires to the battery. (see Figure 44). 4. Connect wires from receiver to TH and TPTH to control valve (see Figure 43, page 24). 5. Locate the two plastic mounting clips provided with the kit. 6. Use the clips to mount the receiver on remote mounting bracket as shown in Figure 45. Fireplace Installation Continued Installing 9-Volt Alkaline Battery in Hand- Held Remote Control Unit 1. Remove battery cover on back of remote control unit. 2. Attach terminal wires to a 9-volt alkaline battery (not included). Place battery into the battery housing. 3. Replace battery cover onto remote control unit. Installing Optional Wireless hand-held REMOTE CONTROL for Electronic Egnition Installing and Activating the Remote Receiver 1. Open bottom louver and locate the plug receptacle. The plug receptacle is located either on the right or left side of cabinet. 2. The WRC model receiver does not require a battery. The receiver can be installed by first plugging the short extension cord into the fireplace receptacle. Then plug the receiver unit into the extension cord. Finally plug the ignition module plug into the receiver unit (see Figure 47). 3. Activate the remote handset battery by removing the insulating tab on the back of the handset (see Figure 48, page 26). The battery is included pre-installed. Battery Cover Remote Control Unit Terminal Wires Battery Housing 9-Volt Battery Figure 46 - Installing Battery in Hand- Held Remote Control Unit Receiver 9-Volt Alkaline Battery Terminal Wires Battery Clip Figure 44 - Attaching Alkaline Battery to Receiver Remote Control Receiver Plastic Mounting Clips Fireplace Receptacle Towards FrontREMOTE ON OFF Extension Cord Ignition Module Plug Remote Receiver Figure 45 - Mountinig Remote Receiver to Bracket Figure 47 - Connecting WRC Remote Control Electronic 4. Once the battery is activated the unit is ready to use. 5. Replace the bottom louver panel. Fireplace Installation Continued Battery Cover Back of Handset 12 Volt Battery Back of Handset Figure 48 - Installing Battery Into Handset WRC High Altitude installation Your DESA direct-vent fireplace has been tested and approved in the USA for elevations from 0-2000 feet (610 m) and in Canada at elevations from 0-4500 feet (1372 m). High-altitude models as indicated by the letter suffix (-HA) are equipped with specific gas controls for installation above 4000 feet. IMPORTANT: Fireplaces when factory equipped for use at high- altitude can not be converted for use with Propane/ LP gas. When installing a non-high altitude fireplace at an elevation above 2000 feet (610 m) (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet (305 m) above sea level. Check with your local gas company for proper derate procedure and orifice size. When installing this fireplace in Canada at an elevation above 4500 feet (1372 m), Check with local or provincial code authorities. Consult your local gas company to help determine the proper orifice for your location. For assistance with any high altitude installation contact DESA’s Customer Service Department at 1-866-672-6040. Check Gas Type Use proper gas type for the fireplace unit you are installing. If your gas supply is not correct, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type or...

Este manual também é adequado para os modelos :
Lareiras - (V)CD36RP (3.69 mb)
Lareiras - (V)CD36RPE (3.69 mb)
Lareiras - (V)CD36TN (3.69 mb)
Lareiras - (V)CD36TNE (3.69 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias