Log:
Assessments - 5, GPA: 4.4 ( )

Instruções de Operação Desa, Modelo (V)CD36TNE

Fabricante : Desa
Arquivo Tamanho: 3.69 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


• There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24" from the front of the termination cap. • Do not locate termination cap where excessive snow or ice build up may occur. Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting system. When using snow blowers, do not direct snow towards vent termination area. Packaging and Removal The (V)CD36R/T direct vent gas fireplace heater is packaged with: - one box containing a 4-log set located on the burner in the firebox. - one bag containing the owner’s manual with installation instructions, operator’s guide, and warranty information. - one bag of glowing ember material. - one bag of vermiculite hearth treatments. Remove the shrink-wrap securing the 2 carton trays to the unit. Lift the top carton tray off and remove the four corner posts. Discard the bottom tray once the unit is moved into position. Note: On rear vent models you must remove the fiberboard collar protector located on the rear collar before installing the fireplace and venting system. See Figure 4. Clearances Minimum clearances to combustibles for the fireplace are as follows: *Back and sides 0"/mm Perpendicular walls 12" (305 mm) Floor 0"/mm Ceiling to louver opening 40" (1016 mm) Front 36" (914 mm) Top of Standoffs 0"/mm Vent Surfaces 1" (26 mm) (See venting instructions for specific vent clearances.) Mantel Clearances (See Mantel Clearances for specifics on mantel clearances.) Combustible material with a maximum thickness of 5/8" may be flush with the top front of fireplace. NOTICE: This fireplace is intended for use as supplemental heat. Use this fireplace along with your primary heating system. Do not install this fireplace as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using fireplace. This will help circulate the heat throughout the house. In the event of a power outage, you can use this fireplace as a heat source. Pre-Installation Preparation Continued Fireboard Collar Protector Figure 4 - Removing Collar Protector (Rear Vent Fireplace) 15" (381 mm) 36" (914 mm) 25" (635 mm) Figure 3 - Fireplace Bottom Dimensions framing and finishing Figure 5 shows typical framing of this fireplace. Figure 6 shows framing for corner installation. All minimum clearances must be met. For overall unit dimensions, framing allowances and vent collar locations, see Unit Dimensions, Figure 9, page 8. For available accessories for this fireplace, see Accessories on page 45. If you are using a separate combustible mantel piece, refer to Figure 7 and Figure 8, page 8 for proper height and clearances. You can install noncombustible mantels at any height above the fireplace. Note: Noncombustible mantels may discolor! Pre-Installation Preparation Continued MANTEL CLEARANCES Figure 7 shows projected mantel depths at various heights above the top of the louver opening. Figure 8, page 8, shows the minimum allowable distances from various mantel components in relation to the both sides of the fireplace opening. WARNING: When finishing appliance, do not overlap combustible materials onto the black front face. Brick, tile, or other non- combustible materials may be applied to the face provided that any fireplace openings are not blocked and gaps in the material used and the face are sealed with a non-combustible caulking. 24" Vertical Double Stud CBADEFG3214567 36" (914 mm) 36 1/4" (921 mm) 14 3/4" (375 mm) Figure 5 - Framing Clearances for Installation Against an Exterior Wall 14 3/4" (375 mm) FOR 1" OF CLEARANCEAT THE SIDES AND BACKOF THE FIREPLACEIS ALSO PERMITTED ATHOWEVER, 0" CLEARANCEALL SIDES WHEN FRAMEDTHESE DIMENSIONS ALLOW21" (533 mm) TO CENTER OFTOP VENT14 3/4" (375 mm) TO NAILINGFLANGES56 3/4" (1441 mm) 12 1/4" (311 mm) TOOPENING28 5/8" (727 mm) 6 5/8" ( 168 mm) TO CENTEROF REAR VENT2 1/2" (63 mm) MIN. 1" (26 mm) Ref. Mantel Depth Ref. Mantel from Top of Louver Opening 1 16" (406 mm) A 14" (356 mm) 2 14" (356 mm) A 12" (305 mm) 3 12" (305 mm) B 10" (254 mm) 4 10" (254 mm) C 8" (203 mm) 5 8" (203 mm) D 6" (152 mm) 6 4" (101 mm) F 4" (101 mm) 7 2" (51 mm) G 2" (51 mm) Figure 6 - Framing Clearances for Corner Installation Figure 7 - Clearances for Combustible Mantels Pre-Installation Preparation Continued 33° SAFEZONE1 1/2" (38 mm) 3 3/4" (95 mm) 6" (152 mm) 5 1/2" (140 mm) 12" (305 mm) PerpendicularSide WallCombustibleMaterial MayBe UsedOuter SurroundTo FireplaceOpening Figure 8 - Side Clearances for Combustible Materials 7 5/8" (194 mm) TO CENTER OF8" TOP VENT14 3/4" (375 mm) TO NAILINGFLANGES5/8" (16 mm) 36" (914 mm) FACE DIM. 36 1/4" (921 mm) FACE DIM. 15 3/8" (390 mm) 35 3/4" (908 mm) 2 " (51 mm) 25" (635 mm) TO CENTER OF8" REAR VENT37" (940 mm) TO NAILINGFLANGE4 1/2" (114 mm) ELECTRICALINLET8" (203 mm) GAS SUPPLYINLET36 3/4" (934 mm) 36 1/4" (921 mm) TO NAILINGFLANGE2" (51 mm) 2" (51 mm) 38" (965 mm) 4" (102 mm) TONAILINGFLANGEWALL SWITCHWIREWAYW...

Este manual também é adequado para os modelos :
Lareiras - (V)CD36RNE (3.69 mb)
Lareiras - (V)CD36RP (3.69 mb)
Lareiras - (V)CD36RPE (3.69 mb)
Lareiras - (V)CD36TN (3.69 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias