|
Facilidade de uso
Each joint in the stove pipe must be secured with at least three sheet metal screws. This room heater must be connected to: 1) A chimney complying with the requirements for Type HT not pivot unit up on its legs, as this could result in damage to the legs. ALCOVE INSTALLATION Model 1100 only may be installed, using a listed double wall connector, such as Security DL6 in Canada, the Simpson Duravent Plus DVL in the USA or an equivalent chimneys in the Standard for Chimneys, Factory-Built, Resi dential Type and Building Heating Appliance UL 103, or double wall connector, into an alcove having a depth of no more than 4 feet and a height of at least 7 feet. The mini mum clearances are as shown in FIGURE 3. 2) A code-approved masonry chimney with a flue liner. Vent the stove into a masonry chimney or an approved, 9" 6" 14" 23" ALCOVE 4 FOOT MAX. insulated solid-fuel stainless-steel chimney with as short and straight a length of six-inch (150mm) diameter smoke pipe as possible. Connection to a masonry chimney must be by a metal or masonry thimble cemented in place. An insulated stainless steel chimney must be supported at the ceiling or roof and its installation must comply with its manufacturer's instructions. FIGURE 3 W415-0512 /C 10.02.06 THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40% OF THE CHIMNEY HEIGHT ABOVE THE STOVE. THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40% OF THE CHIMNEY HEIGHT ABOVE THE STOVE. lar concealed space, or through a floor, ceiling, wall or partition, or any combustible construction. DO NOT USE ANY MAKESHIFT MATERIALS DURING INSTALLATION. 1. Move the stove into position with the flue centered, midpoint between two joists to prevent having to cut them. Use a plumb bob to line up the centre. 2. Cut and frame an opening in the roof to provide a 2" clearance between the outside of the chimney and any combustible material. DO NOT FILL THIS SPACE WITH ANY TYPE OF MATERIAL. Nail headers between the joist for extra support. Firestop spacers must be placed on the bottom of each framed opening in any floor or ceiling that the chimney passes through. 3. Hold a plumb bob from the underside of the roof to determine where the opening in the roof should be. Cut and frame the roof opening to maintain proper 2" clear- UNDERSIDE OF JOIST FIRESTOP SPACER HEADERS ances. Add chimney sections, according to the manufacturers installation instructions, securely, to the required height. The chimney must extend, at least, 3 feet above its point of contact with the roof and at least 2 feet higher than any wall, roof or building within 10 feet. FIGURE 6. If your chimney system is enclosed within the attic area, a rafter radiation shield is required. FIGURE 5 ADDING CHIMNEY SECTIONS FIGURE 6 3 FT. MIN. 10 FT. 2 FT. MIN. W415-0512 / C 10.02.06 PEDESTAL MODELS OUTSIDE AIR If possible connect the air intake at the pedestal's back or bottom to the outside with a 4 inch (100mm) diameter fresh air kit available at your Napoleon/Wolf Steel Ltd. dealer. Follow detailed instructions under "Mobile Home Outside Air". PEDESTAL BASE4.5"PEDESTAL BASE FLOORAREABELOW STOVE A" B" FIGURE 7 A (in.) B(in.) 1100 8 5/8" 9 3/4" 1400 11 1/8" 9 3/4" 1900 14 7/8" 9 3/4" WALL PASS-THROUGH If possible, design the installation so that the connector does not pass through a combustible wall. If during your installation you must pass through a combustible wall, check with your building inspector before you begin. Also check with the chimney connector manufacturer for any specific requirements. Consult with your dealer regarding special connection components available for use for wall pass-throughs. Use only parts that have been tested and listed for use in a wall pass-through. FIGURE 8 MOBILE HOME PEDESTAL MODEL 1100 IS APPROVED FOR INSTALLATION IN MOBILE HOMES IN BOTH CANADA AND THE UNITED STATES. 1150 IS NOT APPROVED FOR MOBILE HOMES. PEDESTAL MODEL 1400 IS APPROVED FOR INSTALLATION IN MOBILE HOMES IN THE UNITED STATES ONLY. WARNING: DO NOT INSTALL IN SLEEPING ROOM. CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED. BACK WALL BACK WALL 6" SIDE WALL10" 2" 45 ° SIDE WALL FIGURE 9 FIGURE 10 The pedestal base must be firmly bolted to the floor with 1/ 4 inch lag bolts. Minimum clearances to combustibles are as shown in FIGURE 9. VENTING Connect the stove to a chimney system using a listed double wall connector. Use a chimney system listed to ULC S629 in Canada or UL103HT in the U.S.A. The chimney must be installed in accordance with the manufacturer's instructions. Use only specified components with no substitutions. The chimney and pipe must extend at least 8 feet above the stove and 3 feet above the highest point of the roof. Install a rain cap at the top which will not impede the smoke exhaust. The chimney must be supported at the ceiling or roof so that its weight does not rest on the stove. FIGURE 11 FIGURE 11 OUTSIDE AIR Connection from the stove's air intake to the outside is ...
Este manual também é adequado para os modelos :Lareiras - EPA1100 (1.02 mb)
Lareiras - EPA1400L (1.02 mb)
Lareiras - EPA1100C (1.02 mb)
Lareiras - EPA1100L (1.02 mb)