Log:
Assessments - 3, GPA: 4.7 ( )

Instruções de Operação Empire Comfort Systems, Modelo PV-28SV55-CN

Fabricante : Empire Comfort Systems
Arquivo Tamanho: 4.33 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


It will be soft during this paint-curing phase. Once cured it will not be soft again. 3. The paint finish of the heater should not be cleaned with any caustic or abrasive cleaning solutions. 4. Any damage to painted surface should be repaired with special touch paint available from your Mantis Dealer. MAINTENANCE Note: Your appliance should be inspected, serviced and checked annually by a qualified service person to ensure that your appliance is operating safe and efficiently. Should you detect any abnormality in the operation of your appliance call a qualified service person who has been trained and approved to inspect and service the appliance. This may be your installer or dealer (routine service is not covered under warranty). 22618-17-0308 Page 45 Page 46 22618-17-0308 MAINTENANCE Figure 55 Front door removal drawing LOG SUPPORT PLATE BURNER PLATE REAR BURNER FRONT BURNER IGNITOR ASSEMBLY FLAME SENSOR Figure 56 Main Burner Drawing Cleaning Main Burner Remove main burner and apply air pressure inside the throat and ports of the main burner. Removing HSI Flame Sensor, Blower and Orifice 1. Remove front door assembly. See Figure 55. 2. Remove logs from firebox. 3. Remove installation bracket and gasket from underside of firebox (1 screw). 4. Disconnect flame sensor and HSI connector from wiring harness. 5. Remove log support from inside firebox (13 screws). 6. Remove HSI from log support (13 screws). 7. Remove flame sensor from log support (1 screw). 8. Remove burners from firebox (1 screw). 9. Once burners are removed, orifices are exposed. Glass Cleaning It will be necessary to clean the glass periodically. During startup, condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also, initial paint curing may deposit a slight film on the glass. It is therefore recommended that the glass be cleaned two or three times with a non-abrasive household cleaner and warm water (we recommend gas fireplace glass cleaner) after the initial burn. We do not recommend using packaged spray type household glass cleaner. After that, the glass should be cleaned two or three times during each heating season depending on the circumstances present. General Glass Information Only glass approved for use in Empire Comfort Systems, Inc. fireplace may be used for replacement. The glass replacement must be done by a licensed or qualified service person. WARNING: 1. The use of substitute glass will void all product warranties. 2. Care must be taken to avoid breakage of the glass. 3. Under no circumstances should this appliance be operated without the glass front or with a broken glass front. Replacement of the glass (with gasket) as supplied by the manufacturer must be done by a qualified service person. 4. Do not abuse the glass by striking or hitting the glass. WARNING: Do not use abrasive cleaners on glass. Do not attempt to clean glass when glass is hot. Glass Assembly Replacement 1. Remove cabinet top. 2. Pivot left and right front panels open. 3. Release two door latches on left and right of firebox. 4. Grasp glass frame and carefully pull toward you. 5. Place glass frame assembly on non-abrasive surface. The exterior of the glass frame assembly should be facing the nonabrasive surface. 6. Insert a putty knife between glass and bottom corners on frame. Carefully separate glass from frame. 7. Use putty knife to remove silicone and gasket material from frame. Surface of frame must be clean and dry. 8. At each corner of frame apply two (2) three inch beads of high temperate (orange) silicone. 9. With thin gasket on glass facing silicone on frame, insert glass into frame. Carefully press the glass onto frame in order to have contact between glass and silicone. 10. Allow silicone to set-up for an adequate time. 11. Gently place glass frame back into firebox. 12. Close the 2 door latches on left and right of firebox. 13. Pivot left and right front panels closed. 14. Replace cabinet top. UNIT OPERATING FAULTS SERVICE AND INSTALLATION OF THE APPLIANCE SHOULD BE CARRIED OUT BY AUTHORIZED PERSONNEL ONLY. THE MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS FIREPLACE HEATERS IS IMPROPER GAS PRESSURE, INCORRECT LOG PLACEMENT, IMPROPER INSTALLATION, INCORRECT FLUE INSTALLATION, INCORRECT SWITCHING OF BURNERS, DIPS/SPIKES IN THE INCOMING POWER OR REVERSE POLARITIES. The above situations can cause such problems as changes in flame color or configuration, intermittent operations, changes in heat output, carbon build up or sooting, bad odors, rattles or other sounds, start up failures and burner(s) switching themselves off. These are nearly always the result of improper installation or incorrect operation and it may take sometime for these problems to show themselves. Before calling out a technician you must be able to repeat the fault, try resetting the heater. Read below. Note: Incorrect installation of the unit, logs, flue pipe, gas pressure or operation, wh...

Este manual também é adequado para os modelos :
Lareiras - BP)-1 (4.33 mb)
Lareiras - CP (4.33 mb)
Lareiras - GN (4.33 mb)
Lareiras - GP)-1 (4.33 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias