Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Hearth and Home Technologies, Modelo 6000G-IPILP

Fabricante : Hearth and Home Technologies
Arquivo Tamanho: 3.54 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


- Use low resistance thermostat wire for wiring from ignition system to the wall switch and thermostat. - Keep wire lengths short as possible. A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA C22.1. • Wire the appliance junction box to 110-120 VAC. This is required for use of optional accessories (standing pilot ignition) or proper operation of the appliance (Intellifi re ignition). • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. • Low voltage and 110 VAC voltage cannot be shared within the same wall box. WARNING! Risk of Shock or Explosion! DO NOT wire 110V to the valve or to the appliance wall switch. Incorrect wiring will damage controls. Determine if the appliance uses an Intellifi re ignition system or standing pilot ignition system: • Open the control access panel or remove the decorative front. • A red or black ignitor button (as shown in Figure 12.1) indicates this appliance is standing pilot ignition. B. Intellifi re Ignition System Wiring • Wire the appliance junction box to 110 VAC for proper operation of the appliance. WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction box to a switched circuit. Incorrect wiring will override IPI safety lockout. • Refer to Figure 12.2, Intellifi re Pilot Ignition (IPI) Wiring Diagram. • This appliance is equipped with an Intellifi re control valve which operates on a 3 volt system. • Plug the 3-volt AC transformer into the appliance junction box to supply power to the unit OR install two D cell batteries (not included) into the battery pack before use. NOTICE: Batteries should not be placed in the battery pack while using the transformer. Remove batteries before using the transformer, and unplug the transformer before installing the batteries. Battery polarity must be correct or module damage will occur. D. Optional Accessories Requirements • This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control. Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories. 12 Electrical Information RED OR BLACK BUTTON 50 Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. O • 12/08 E. Electrical Service and Repair WARNING! Risk of Shock! Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Figure 12.2 Intellifi re Pilot Ignition (IPI) Wiring Diagram Figure 12.3 Standing Pilot Ignition Wiring Diagram WARNING! Risk of Shock! Replace damaged wire with type 105. C rated wire. Wire must have high temperature insulation. THERMOSTAT ON/OFF PIGGYBACK WIRE WIRE ASSEMBLY BRN VALVE WHT RED RED STANDING PILOT PLUG-IN 3V TRANSFORMER ON/OFF WALL SWITCH IGNITION MODULE (3V) VALVE NEUTRAL GROUND LOW VOLTAGE SEE NOTE 1 REMOTE CONTROL HOT PLUG-IN REMOTE JUMPER WIRE ORG GRN BRN BRN RED BLK INTERMITTENT PILOT IGNITOR ORG WHT IGNITION MODULE 3 VAC TRANSFORMER VALVE 3 VAC THERMOSTAT WIRE ASSEMBLY BLACK WIRE CAN BE PLUGGED INTO ANY OF #1 - #5 LOCATIONS ON THE HOT SIDE WHITE WIRE CAN BE PLUGGED INTO ANY OF#1 - #5 LOCATIONS ON THE NEUTRAL SIDE GROUND TO FIREPLACE CHASSIS* F. Junction Box Installation If the box is being wired from the INSIDE of the appliance: • Remove the screw attaching the junction box/receptacle to the outer shell, rotate the junction box inward to disengage it from the outer shell (see Figure 12.4). • Pull the electrical wires from outside the appliance through the opening into the valve compartment and secure wires with a Romex connector. See Figure 12.4. • Make all necessary wire connections to the junction box/ receptacle and reattach the junction box/receptacle to the outer shell. WHT WHTBLK BLK GRN wire inside box Copper ground attached to GRN screw with GRN wire 14/2WG Cover Plate outside firebox Romex Connector Figure 12.4 Junction Box Detail NOTICE: DO NOT wire 110 VAC to wall switch. G. Wall Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.5): • The power supply for the appliance must be brought into a switch box. • The power can then be supplied from the switch box to the appliance using a minimum of 14-3 with ground wire. • At the switch box connect the black (hot) wire and red (switch leg) wire to the wall switch as shown. • At the appliance connect the black (hot), white (neutral) and green (ground) wires to the junction box as shown. • Add a 1/4 in. insulated female connector to the red (switch leg) wire, route it through the knockout in the face of ...

Este manual também é adequado para os modelos :
Lareiras - 6000G (3.54 mb)
Lareiras - 6000G-IPI (3.54 mb)
Lareiras - 6000G-LP (3.54 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias