Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Stovax, Modelo AR0887

Fabricante : Stovax
Arquivo Tamanho: 383.21 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The pilot should now light. If the pilot does not light, release the knob and repeat the procedure until it does. 2.6 Keep the control knob pressed in for 10 seconds and then release it, the pilot should stay alight. If the pilot goes out, repeat the procedures until it remains lit. 2.7 If the pilot does not light after repeated attempts, contact the retailer or installer from whom the appliance was purchased. 2.8 Turn the right-hand control to point to main burner ( ). The appliance can now be controlled using the left-hand control knob. 2.9 Turn the left-hand control knob to point to low fire ( ), the main burner lights on low. The burner can now be controlled between low and high settings. Turn the control knob anticlockwise to increase the flame height and clockwise to decrease the flame height. THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE HAS REACHED SUFFICIENT HEAT - TYPICALLY 10 TO 20 MINUTES. IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO RELIGHT THE APPLIANCE. 4 USER INSTRUCTIONS 1.1 Installation and servicing must be carried out by a competent person in accordance with Gas Safety (Installation and Use) Regulations 1998, the relevant British Standards for Installation, appropriate Codes of Practice and in accordance with the manufacturers instructions. It is a requirement that a CORGI registered engineer be used for this purpose as they are approved by the HSE under the above regulations. 1.2 This appliance is suitable for use in G.B. and I.E. using Natural Gas at a supply pressure of 20mbar or LPG at a supply pressure of 29mbar (Butane) or 37mbar (propane). 1.3 The installation shall also be completed in accordance with: The Building Regulations issued by The Department of The Environment. The Building Standards (Scotland) Regulations issued by the Scottish Development Department. For Republic of Ireland, reference should be made to the relevant standards governing installations (IS813:1996) 1.4 Read all these instructions before commencing installation. 1.5 This appliance must be installed in accordance with the rules in force and only used in a sufficiently ventilated space. 1.6 Ensure that curtains are not positioned above the stove, and that there is at least a clearance of 300mm between the sides of the stove and any curtains. 1.7 The manufacturer considers the full outer casing of this stove to be a working surface which becomes hot whilst in operation. A suitable guard is recommended to protect young children, the aged and the infirm. 1.8 This stove must only be operated with the door secured firmly in position. If any cracks appear in the glass the appliance must not be used until the glass panel is replaced. 1.9 Do not attempt to burn rubbish in this stove. 1.10 Any combustible shelves or surrounding furniture must only be fitted in accordance with the minimum dimensions detailed in diagram 1. 1.11 Contact a competent service engineer to carry out relevant spillage checks etc. following home improvements carried out after installation of this stove (e.g. the fitting of double glazing). 1. GENERAL 2. LIGHTING THE APPLIANCE 1 2 AR0914 5 3.1 To turn the stove off, locate the control valve, turn the lefthand control knob until it points to off ( ). The main burner goes out leaving the pilot burning. 3.2 To turn the pilot off, locate the control valve, turn the righthand control knob until it points to off ( ), the pilot goes out. 4.1 Your stove is fitted with a control valve that can easily be upgraded to battery powered remote control. This upgrade can be fitted by anyone capable of simple DIY jobs and requires no special training. There are two versions of this control which can be obtained through your local Gazco stockist. 4.2 STANDARD REMOTE CONTROL. This remote controls the gas appliance after the pilot has been lit. It can turn the main burner on and regulate it from low through to high and back again. It can turn the main burner off leaving the pilot burning GAZCO PART NUMBER 8455. 4.3 THERMOSTATIC AND TIMER REMOTE CONTROL. This remote controls the gas appliance after the pilot has been lit. In ‘MANUAL MODE’ it can be used to turn the main burner on and manually regulate it from low through to high and back again. It can also be used to turn the main burner leaving the pilot burning. In ‘AUTO MODE’ it will automatically regulate the room temperature to a pre-set temperature. In ‘TIMER MODE’ it will turn the fire on and off according to a pre-set programme and automatically regulate the room temperature during the two ON periods. GAZCO PART NUMBER 8456. WARNING: DO NOT ATTEMPT TO CLEAN THE STOVE UNTIL IT IS COLD. THE STOVE RETAINS ITS HEAT FOR A CONSIDERABLE TIME AFTER SHUTDOWN. 5.1 Carefully remove the ceramic fuel bed components and place to one side taking care to protect floor coverings etc, PLEASE HANDLE WITH CARE. 5.2 The coals should not require cleaning. Do not use a vacuum cleaner or brush to clean the coals, any large pieces of debris ...

Este manual também é adequado para os modelos :
Lareiras - AR0367 (383.21 kb)
Lareiras - AR0366 (383.21 kb)
Lareiras - AR0368 (383.21 kb)
Lareiras - AR0369 (383.21 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias