Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Enviro, Modelo Vented EG 28 B

Fabricante : Enviro
Arquivo Tamanho: 542.12 kb
Arquivo Nome : 16b3abfc-ed08-4db4-84a3-ea273438ddce.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


If practical, it is best to locate the appliance to permit the use of shorter horizontals and fewer elbows. -Two 90° elbow, maximum total horizontal length of 20 ft (6m). -Three 90° elbow, maximum total horizontal length of 13 ft (3.8m). -Four 90° elbow, maximum total horizontal length of 6 ft (1.9m). -Five 90° elbow, maximum total horizontal length of 0 ft (0m). If 45° elbows are used, one 90° elbow is equivalent to two 45° elbows. Venting rise should be a minimum of 1 ft (.31m). from the top of the unit before any horizontal run. The bottom of the vent cap shall extend at least 2 ft. (.6m) above the highest point of the roof where it passes through and at least 2 ft (.6m) higher than any portion of the roof within a horizontal distance of 10 ft. (3m). INSTALLATION OF LOG SET and EMBERS INSTALLING THE GLOWING EMBERS A bag of Rock Wool embers is provided for use on the burner tray. CAUTION: Use only the type of ember material supplied with this appliance. Due to the irregular size of the ember material there may be more than required. If over time, through cleaning and servicing, these embers require replacement, contact your nearest ENVIROGAS dealer for replacement embers. Remove the ember material from the plastic bag. Cover the shaded areas in the diagram shown beside. Totally fill these areas with glowing ember material Do not pack down, leave embers loose. CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE DOOR REMOVED INSTALLING THE LOGSET Carefully remove log from box. Check to ensure there is no damage. It is very important to install this log in its proper position to insure safe, optimum operating conditions. 1. Open the front door. 2. Place each piece of the log set into the firebox resting the pins in the holes in the log supports. 3. Close the door and tighten securely. Upon the first light up, watch for ignition to all burner ports. If a long delay is noted: a) First, wait for the appliance to cool down b) Open the front door of the appliance. (See adjusting the venturi section to adjust air for proper flame). OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A) This appliance is equipped with a pilot, which must be lit by hand by following these instructions exactly. B) BEFORE LIGHTING smell all around the appliance area for gas, and next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. C) Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it . Call a qualified service technician. Force or attempted repair may result in a fire or explosion. D) Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above. 2. Turn off all electrical power to the appliance. 3. Turn the gas control knob clockwise to the “off’ position. 4. Open door. Wait five (5) minutes to clear out any gas. Close door. If you smell gas including near the floor, STOP! Follow “B” in the above safety information. If you don’t smell gas go to next step. 5. Find the pilot located to the right between the front and rear burner. 6. Turn gas control knob counter- clockwise to “PILOT”. 7. Push the gas control knob in fully and hold. Immediately light the pilot by pushing the piezo spark igniter. Keep knob depressed for about 30 seconds after pilot is lit. Release knob. If pilot goes out, repeat steps 4 through 6. WARNING The gas valve has a lockout device, which will not allow the pilot burner to be re-lit until the thermocouple, has cooled. If the knob does not pop up when released, stop and immediately call your service technician or gas supplier. NOTE: Check to be sure the pilot flame engulfs the thermocouple and that the burners light completely. If the pilot will not stay lit after several tries, turn the gas control knob to “OFF" and call you service technician or gas supplier. 8. Turn gas control knob counter-clockwise to the “ON” position. Flip burner switch to “ON” then turn “HI / LO” knob to the desired setting. 9. Turn on all electrical power to the unit Text Box: HI \ LO knob Control knob TO TURN OFF GAS TO APPLIANCE Turn the gas control knob clockwise to “OFF” DO NOT FORCE 1. Turn off all electrical power to the appliance if service is to be performed. 2. Flip burner switch to off. MAINTENANCE AND TECHNICAL Annually che...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias