Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Stovax, Modelo 8517-P8517

Fabricante : Stovax
Arquivo Tamanho: 603.72 kb
Arquivo Nome : 8c2bc0c2-ee35-4b98-93b0-90494c069b24.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


518 Place six small coals along the rear of the flame baffle, resting against the rear ledge, see diagram 21. NOTE: ENSURE THAT THE COALS ARE POSITIONED, AS DETAILED ABOVE. ONLY USE THE CORRECT AMOUNT OF COALS, AS SPECIFIED IN DIAGRAMS. 5.19 Ensure that the fibreglass seal on the back of the door is intact, locate the door on the four studs and slide back to the firebox. Secure in place using the four brass nuts and the tool supplied, do not over tighten the nuts, see diagram 22. Keep the tool with these instructions for future use. NEVER OPERATE THE STOVE WHEN THE DOOR IS REMOVED OR WHEN THE GLASS IS BROKEN. Go to page 17, COMMISSIONING. 20 21 22 AR0373 AR0374 AR0390 17 INSTALLATION INSTRUCTIONS COMMISSIONING 1.1 Close all openable doors and windows in the room. Ignite the stove and operate on maximum for 10 minutes. Remove the plastic sight plug from the right-hand side of the stove. Position a lighted smoke match just inside the draught diverter opening and check that all smoke is drawn into the opening. Watch through the viewing hole in the side of the casing. In restricted locations a mirror can be used. See diagram 1. If there is any doubt, run the stove for a further 10 minutes, and repeat the test. 1.2 If there are any extractor fans in adjacent rooms, the test must be repeated with the fans running on maximum and interconnecting doors open. IF SPILLAGE PERSISTS, DISCONNECT THE APPLIANCE AND SEEK EXPERT ADVICE. For future reference record the installation details on the Appliance Commissioning Checklist on page 3 of these instructions. 1. COMMISSIONING 1 18 IGNITION FUNCTIONAL CHECK 1 PILOT WILL NOT LIGHT Ensure there is no debris around the pilot assembly, (e.g. soot, etc.) which could short the spark, clean the area. Operate the valve. Is there a spark? Consult Section 2 on page 4 and retry. Check alignment of pilot burner head. Change the ignition lead, see diagram 1, Servicing Requirements. Check isolation tap and gas meter, retry. Correct and retry. Purge the gas pipes and retry. SEE 'NO SPARK' CHART SYSTEM OK There is a blockage in the system, check the inlet test point, the mag seating, valve and pilot filter. Is the gas turned on to the appliance? Is the gas pressure correct? Has the system got any air in it? Does the pilot light? Is the control being operated correctly? Will the pilot light with a match? No Yes No Yes No Yes Yes No No Yes No No Yes Yes SERVICING INSTRUCTIONS SERVICING / FAULT FINDING CHARTS This appliance must be serviced at least once a year by a competent person. All tests must be serviced by best practice as described by the current CORGI recommendations. Refer to ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS In User Instructions section 5 1.1 Before any tests are undertaken on the appliance, conduct a gas soundness test for the property to ensure there are no gas leaks prior to starting work. 1.2 Before any tests are undertaken on the appliance it is also recommended to fully check the operation of the appliance. 1.3 Special checks 1.3.1 Clean any lint or fluff from the pilot - pay particular attention to the aeration hole in the side of the pilot 1.3.2 Clean away any fluff or lint from under the burner 1.3.3 Check the spark gap on the pilot is correct 1.4 Correct any faults found during the initial tests and then recommission the appliance conducting the usual safety checks. 1.5 Advise the customer of any remedial action taken. 1. SERVICING REQUIREMENTS 1 19 PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE Ensure there is no debris around the pilot assembly, e.g. coal, soot etc. which could short the spark, clean the area. Problem is with the pipework or fittings which lead to the fire. Correct and retry. Is thermocouple connection good in back of valve? Replace oxypilot. Will pilot stay alight? Change mag unit. Is the pilot flame of the correct length? See diagram 1, Servicing Requirements Change the pilot unit. Will pilot With the pilot stay lit? running is the gas pressure stated on the databadge? With the fire running on full is the gas at the pressure stated on the databadge? Run for no more than 60 seconds turn off, time interval until mag unit shuts with a click. Is this greater than 7 seconds? Run for a maximum of 60 seconds, turn off, time interval until mag unit shuts with a click. Is this greater than 7 seconds? Tighten the connection and retry. No No No No No No Yes SYSTEM OK Yes Yes Yes Yes No Yes Yes No Light the pilot and keep the control knob pushed in at least 10 seconds before letting go. FLAME FAILURE FUNCTIONAL CHECK SERVICING INSTRUCTIONS FAULT FINDING CHARTS IGNITION FUNCTIONAL CHECK 2 NO SPARK Ensure there is no debris around the pilot assembly, (e.g. coal, soot etc.) which could short the spark, clean the area. Consult Section 2 on page 4, retry. Operate the valve to light the pilot, does the valve 'click'? Is the pIlot burner horizontal? See diagram 1, Servicing Requirements Has ignition lead become detached or is connection poor? Remove the ...

Este manual também é adequado para os modelos :
Lareiras - Clarendon & Ashdon ASHDON 8513-P8513 (603.72 kb)
Lareiras - Clarendon & Ashdon CLARENDON 8541-P8541 (603.72 kb)
Lareiras - 8518-P8518 (603.72 kb)
Lareiras - 8519-P8519 (603.72 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias