Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Lenovo, Modelo THINKCENTRE 8126

Fabricante : Lenovo
Arquivo Tamanho: 7.28 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


See “Flash update procedures” on page 214 3. Go to “Undetermined problems” on page 90 000-199-XXX BIOS test failed, cause unknown 1. Go to “Undetermined problems” on page 90 2. Flash the system and re-test 3. Replace component under function test 000-250-XXX BIOS APM failure 1. Flash the system. See “Flash update procedures” on page 214 2. System board 000-270-XXX BIOS ACPI failure 1. Flash the system. See “Flash update procedures” on page 214 2. System board 001-000-XXX System Test Passed No action 001-00X-XXX System Error System board 001-01X-XXX System Error System board 001-024-XXX System Addressing test failure System board 001-025-XXX System Checksum Value error 1. Flash the system. See “Flash update procedures” on page 214 2. System board 001-026-XXX System FLASH data error 1. Flash the system. See “Flash update procedures” on page 214 2. System board 62 Hardware Maintenance Manual Diagnostic Error Code FRU/Action 001-027-XXX System Configuration/Setup error 1. Run Setup 2. Flash the system. See “Flash update procedures” on page 214 3. System board 001-032-XXX System Device Controller failure System board 001-034-XXX System Device Buffer Allocation failure 1. Reboot the system 2. Flash the system. See “Flash update procedures” on page 214 3. Run memory test 4. System board 001-035-XXX System Device Reset condition detected System board 001-036-XXX System Register error System board 001-038-XXX System Extension failure 1. Adapter card 2. System board 001-039-XXX System DMI data structure error 1. Flash the system. See “Flash update procedures” on page 214 2. System board 001-040-XXX System IRQ failure 1. Power-off/on system and re-test 2. System board 001-041-XXX System DMA failure 1. Power-off/on system and re-test 2. System board 001-195-XXX System Test aborted by user Information only Re-start the test, if necessary 001-196-XXX System test halt, error threshold exceeded 1. Press F3 to review the log file 2. Re-start the test to reset the log file 001-197-XXX System test warning 1. Make sure the component that is called out is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 55 2. Re-run test 3. Replace the component that is called out in warning statement 4. Replace the component under test 001-198-XXX System test aborted 1. If a component is called out, make sure it is connected and/or enabled. See Chapter 6, “Using the Setup Utility,” on page 55 2. Flash the system and retest. See “Flash update procedures” on page 214 3. Go to “Undetermined problems” on page 90 Chapter 7. Symptom-to-FRU Index 63 Diagnostic Error Code FRU/Action 001-199-XXX System test failed, cause unknown 1. Go to “Undetermined problems” on page 90 2. Flash the system and re-test 3. Replace component under function test 001-250-XXX System ECC error System board 001-254-XXX 001-255-XXX 001-256-XXX 001-257-XXX System DMA error System board 001-260-XXX 001-264-XXX System IRQ error System board 001-268-XXX System IRQ1 failure 1. Device on IRQ1 2. System board 001-269-XXX System IRQ2 failure 1. Device on IRQ2 2. System board 001-270-XXX System IRQ3 failure 1. Device on IRQ3 2. System board 001-271-XXX System IRQ4 failure 1. Device on IRQ4 2. System board 001-272-XXX System IRQ5 failure 1. Device on IRQ5 2. System board 001-273-XXX System IRQ6 (diskette drive) failure 1. Diskette Cable 2. Diskette drive 3. System board 001-274-XXX System IRQ7 failure 1. Device on IRQ7 2. System board 001-275-XXX System IRQ8 failure 1. Device on IRQ8 2. System board 001-276-XXX System IRQ9 failure 1. Device on IRQ9 2. System board 001-277-XXX System IRQ10 failure 1. Device on IRQ10 2. System board 001-278-XXX System IRQ11 failure 1. Device on IRQ11 2. System board 001-279-XXX System IRQ12 failure 1. Device on IRQ12 2. System board 001-280-XXX System IRQ13 failure 1. Device on IRQ13 2. System board 64 Hardware Maintenance Manual Diagnostic Error Code FRU/Action 001-281-XXX System IRQ14 (hard disk drive) failure 1. Hard disk drive cable 2. Hard disk drive 3. System board 001-282-XXX System IRQ15 failure 1. Device on IRQ15 2. System board 001-286-XXX 001-287-XXX 001-288-XXX System Timer failure System board 001-292-XXX System CMOS RAM error 1. Run Setup and re-test 2. System board 001-293-XXX System CMOS Battery 1. Battery 2. System board 001-298-XXX System RTC date/time update failure 1. Flash the system. See “Flash update procedures” on page 214 2. System board 001-299-XXX System RTC periodic interrupt failure System board 001-300-XXX System RTC Alarm failure System board 001-301-XXX System RTC Century byte error 1. Flash the system. See “Flash update procedures” on page 214 2. System board 005-000-XXX Video Test Passed No action 005-00X-XXX Video error 1. Video card, if installed 2. System board 005-010-XXX 005-011-XXX 005-012-XXX 005-013-XXX Video Signal failure 1. Video card, if installed 2. System board 005-016-XXX Video Simple Pattern test failure 1. Video Ram 2. Video card, if installed 3. System board 005-024-XXX Video ...

Este manual também é adequado para os modelos :
Acessórios de computador - THINKCENTRE 8178 (7.28 mb)
Acessórios de computador - THINKCENTRE 8084 (7.28 mb)
Acessórios de computador - THINKCENTRE 8085 (7.28 mb)
Acessórios de computador - THINKCENTRE 8147 (7.28 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias