Log:
Assessments - 4, GPA: 4 ( )

Instruções de Operação Dell, Modelo SPARC ENTERPRISE M4000

Fabricante : Dell
Arquivo Tamanho: 309.11 kb
Arquivo Nome : m4m5-product-1041-en-04.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


None available at this time. Set the following to /etc/system and then reboot the domain: set pcie:pcie_aer_ce_mask = 0x2001 Do not insert a different type of PCI-X card on the same PCI slot card by using PCI hot plug. None available at this time. There is no workaround. Check for the availability of a patch for this defect. To mask these errors with Dual-Channel Ultra320 SCSI Card (SE0X7SC2F, SE0X7SC2X), add the following entry to the /etc/system file and then reboot the system: set pcie:pcie_aer_ce_mask = 0x31c1 This message can be safely ignored. SPARC Enterprise M4000/M5000 Servers Product Notes 19 TABLE 6 Specific Issues and Workarounds Concerning Solaris (Continued) TABLE 6 Specific Issues and Workarounds Concerning Solaris (Continued) Description Workaround 6515648 "Replumb Failed" error appears when dr@0:SB1::memory fails. Once the DR operation is complete, it can be plumbed up manually. Example steps to re-plumb the interface manually: # ifconfig interface plumb xxx.xxx.xxx.xxx netmask + broadcast + up # ifconfig interface group group-name # ifconfig interface addif xxx.xxx.xxx.xxx -failover deprecated up This workaround assumes that the /etc/hostname.interface file is correctly configured for the IPMP group and does not need any modification. The IP addresses used in the example above should match what was previously used and what matches the /etc/hostname. file. 6516135 Ap_Id format and devices may not be shown correctly by cfgadm(1M). Use the following operations to display all of the PCI slots. 1) devfsadm (at Solaris prompt) 2) cfgadm 6519290 Large amounts of I/O on swap devices can cause the system to appear hung by over welling the I/O system. The amount of I/O required can be generated through a number of ways, eg memory shortage, heavy use of /tmp etc. Set the following to /etc/system and then reboot the domain: set maxfastscan=0x2000 6520990 Domain may cause a panic when deleteboard(8) command for kernel board by using Dynamic Reconfiguration (DR). To mask this error, add the following entry to the /etc/system file. set drmach:fmem_timeout = 30 6522017 DR and ZFS may not be used in the same domain. Set the maximum size of the ZFS ARC lower. 6522433 After the CPU hardware error occurred, the fmdump(1M) command on the domain may display an incorrect faulty component. Check system status on XSCF. 6525010 PCIe correctable errors can be recorded in the FMA error log. Add the following entry to /etc/system to prevent the problem: set pcie:pcie_aer_ce_mask = 0x2001 20 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1041 • October 2007 TABLE 6 Specific Issues and Workarounds Concerning Solaris (Continued) TABLE 6 Specific Issues and Workarounds Concerning Solaris (Continued) n Workaround 6527811 showhardconf(8) on XSCF can not display PCI card information that is installed in External I/O Expansion Unit, if the External I/O Expansion Unit is configured using PCI hotplug. 6529479 ereport.io.ddi.fm-capability error messages may be logged in ereport during system reboot. 6529714 Warning messages occur while trying to configure more than four X4447A-Z or X1027A-Z1 cards into one I/O Boat. 6530178 DR addboard(8) command can hang. Once problem is observed, further DR operations are blocked. Recovery requires reboot of the domain. 6530288 Ap_Id format may not be shown correctly by cfgadm(1M) command. 6530753 Some of the PCI slots in the External I/O Expansion Unit PCI slots are not displayed during a normal boot operation. 6531036 The error message network initialization failed appears repeatedly after a boot net installation. 6531668 System hangs when executing parallel hot plug operation with SP DR in suspend phase. 6532215 volfs or dscp service may fail when domain is booted. svc:/platform/sun4u/dscp:default: Method "/lib/svc/method/svc-dscp start" failed with exit status 95. svc:/system/filesystem/volfs:defaul t: Method or service exit timed out. Killing contract 59. No workaround is available at this time. In case of each PCI card in the External I/O Expansion Unit is configured using PCI hotplug, the PCI card information is displayed correctly. None available at this time. Ignore the messages. No workaround available at this time. There is no workaround. Check availability of a patch for this bug. None available at this time. Use one of the following operations to display all of the PCI slots. • boot -r (at open boot prompt) • devfsadm -C (at Solaris prompt) • cfgadm (twice at Solaris prompt) There is no workaround. No workaround available at this time. Restart the service if the failure is observed. To avoid the problem, issue the following commands. # svccfg -s dscp setprop start/timeout_seconds=count: 300 # svccfg -s volfs setprop start/timeout_seconds=count: 300 # svcadm refresh dscp # svcadm refresh volfs SPARC Enterprise M4000/M5000 Servers Product Notes 21 TABLE 6 Specific Issues and Workarounds Concerning Solaris (Continued) TABLE 6 Specific Issues and Workaro...

Este manual também é adequado para os modelos :
Computadores - SPARC ENTERPRISE M4000 (309.11 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias