Log:
Assessments - 0, GPA: 4 ( )

Instruções de Operação Fujitsu, Modelo SPARC ENTERPRISE M4000

Fabricante : Fujitsu
Arquivo Tamanho: 309.11 kb
Arquivo Nome : m4m5-product-1041-en-04.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


DIMMs in group B are optional. ¦ For both groups, DIMMs must be of the same capacity and rank within a group. DIMMs of different capacity cannot be mixed in a group. 12 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1041 • October 2007 Software Issues Software Issues XCP Issues and Workarounds TABLE 5 lists known XCP issues and possible workarounds. TABLE 5 XCP Issues and Workarounds ID Description Workaround RTIF1070418- 004 RTIF1070418- 005 RTIF1070418- 009 RTIF1070418- 010 RTIF1070418- 011 RTIF1070418- 012 RTIF1070418- 020 All domains must be powered off before upgrading the XCP firmware. If you log in to the XSCF while it is still booting, you may get a bash$ prompt instead of the XSCF> prompt, and be unable to perform most operations. While XSCF is running, error message of "OOM kill" might be displayed to XSCF console, and process may go down and/or watchdog timeout may occur and XSCF may reboot. The showdomainstatus -a command shows domain status as Powered Off, but the showboards -a command shows the domain is testing. Some commands that update configuration data take a relatively long time to execute. The fault (memory.block.ue) is encountered and reported periodically. When using the XSCF Web to import a firmware image, if the image is corrupted, the flashupdate command might later report an internal error. Power off domains before using the flashupdate(8) command to upgrade XCP firmware. Log out of the bash$ prompt and wait for the XSCF to finish booting. Check that XSCF is started. If not started, use the rebootxscf(8) command to restart XSCF, or stop all the domains and then execute the system power off/on (AC OFF/ON). Use the showboards command to check the status of domain power. The showdomainstatus command takes a longer time to show the correct status. Do not cancel set* commands. They appear to hang, but eventually complete in about 30 seconds. An uncorrectable error exists in a DIMM and the DIMM should be replaced. Import again a firmware image. Reboot the XSCF Unit, then use the flashupdate command again to clear the internal error. SPARC Enterprise M4000/M5000 Servers Product Notes 13 TABLE 5 XTABLE 5 XID Description Workaround RTIF1Using the rebootxscf(8) command may Ignore this event. 070418-023 result in a process down error, and possibly an FMA event with MSG ID SCF-8005-NE. RTIF1showaudit all shows a long list of defaults Update the database with the following: 070418-025 in the policy section after the database is cleared. setaudit -a opl=enable setaudit -a opl=default RTIF1When you have updated the /etc/ttydefs file of None available at this time. 070528-001 Solaris to disable the console flow control, you cannot disable the console flow control on the telnet via a server. RTIF1While XSCF is running, watchdog timeout Check that XSCF is started. If not started, use 070528-002 may occur and XSCF may reboot. the rebootxscf(8) command to restart XSCF, or stop all the domains and then execute the system power off/on (AC OFF/ON). RTIF1When connected to telnet, the login or the Disconnect the telnet session and try again. 070802-001 password prompt doesn't appear. RTIF1When remote power control mode of After XSCF Unit is replaced, configures the 070824-001 interlocking mechanism for power supply to RCI again and sets the remote power control domain, is enabled, after XSCF Unit is mode. replaced, the interlocking for power supply by RCI cannot work. RTIF1When the snapshot CLI attempts to write to a Do not attempt to use write-protected USB 070904-002 USB stick that has write protect set results in devices for collecting snapshot. an I/O error. RTIF1An incorrect domain state is reported. After There is no workaround. This is expected 070904-003 the command sendbreak to domain is issued, behavior of the sendbreak operation. showdomainstatus continues to show the state as "Running" when the domain is actually at "ok" prompt. RTIF1The latest communication field in Disabling and re-enabling archiving refreshes 070904-004 showarchiving is not updated regularly. the Latest communication field in showarchiving output. 14 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1041 • October 2007 TABLE 5 XTABLE 5 XID Description Workaround RTIF1070904- 005 Time can't be synchronized with the NTP server. Check the stratum value of the NTP server. The stratum value of XSCF is "5." The NTP server which the XSCF refers to must be a server on which the stratum value is smaller than 5. When you changed the NTP server to refer to, reboot the XSCF. When the stratum value has been set correctly and the time can't be synchronized, use the showntp(8) command to check the jitter value to be displayed. If this value is large, please reboot the XSCF. RTIF1070904- 006 While executing the domain power-on, domain reset or DR, in case the XSCF reboot occurred, the process may be aborted in some or all of the XSB. Execute the domain reset one more time, or power off the domain and th...

Este manual também é adequado para os modelos :
Computadores - SPARC ENTERPRISE M4000 (309.11 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias