(Under this condition, the water pump is not activated.) 6 INSTALLATION Install the mobile ir conditioner in a flat and spacious location where the air outlets will not be covered up. A minimum clearance of 30cm from a wall or other obstacles should be kept. The appliance shall not be used in the laundry. The plug shall accessible after appliance is positioned. Wiring shall be done according to National rules. 1 IMPORTANT: 2 DUCT MOUNT INSTRUCTIONS: Exhaust Air Oulet Duck A) TEMPORARY- 1. Attach one end of the duct to the exhaust air outlet of the mobile air condition, first fit the left side of the duct on the exhaust air panel, then the right side duct. Push it downwards, be sure to fix thoroughly. (See the figures) 2. Attach the other end of the duct to adaptor B. 3. Put the end of duct to a nearby window. B) PERMANENT- 1. Attach one end of the duct to the exhaust air outlet of the mobile air conditioner. According to the arrow direction, first fit the left side of the duct on the exhaust air panel, then the right side duct. Push it downwards, be sure to fix thoroughly. (See the figures) 2. Install the adaptor A onto the wall by using 4 wall plug and screws, be sure to fix thoroughly. (See the figures) 3. Attach the other end of the duct to adaptor A. 4. Cover the hole using the adaptor cap when not in use. The duct can be compressed or extended between 500mm and 2000mm, but it is desirable to keep the duct length to a minimum. IMPORTANT: DO NOT OVER BEND THE DUCT (SEE FIGURE) Adapter A Rawlplugs Skruer max 120CM min 30CM Fig.8 Fig.9 Fig.10 30cm 30cm Fig.7 7 Your window kit has been designed to fit most standard Vertical and horizontal window applications, However, it may be necessary for you to improvise/modify some aspects of the installation procedures for certain types of window. Please refer to Fig. 11 & Fig. 11a for minimum and maximum window openings. Window Kit Installation Horizontal window Window Slider Kit Minimum:67.5cm(2.22ft). Maxmum:123cm(4.04ft). Window Slider Kit Minimum:67.5cm(2.22ft). Maxmum:123cm(4.04ft). Horizontal window This unit is equipped with a internal water tank, two full-safe switch mechanisms, one is used to control the water pump drainage, the other is used to monitor the water level inside the internal water tank. When the water level reaches a predetermined level, the full-safe switch mechanism is activated. The digital display shows P1 and the water full indicator light illuminates. Carefully move the unit outside, remove the rubber blockage from the back drainage hole and drain the water off. The unit will continue operating properly. Drain Tank Safety Feature MAINTENANCE 1) BE SURE TO UNPLUG THE UNIT BEFORE CLEANING. 2) DO NOT USE GASOLING, THINNER OR OTHER CHEMICALS TO CLEAN THE UNIT. 3) DO NOT WASH THE UNIT DIRECTLY UNDER A TAP OR USING A HOSE. THE ELECTRICAL CAUE DANGER. 4) IF THE POWER CORD IS DAMAGED, IT SHOULD BE REPAIRED BY MANUFACTURE OR ITS AGENCY. IMPORTANT: 1 AIR FILTER - Clean the air filter at ...
Este manual também é adequado para os modelos :Aparelhos de ar condicionado - DOC-091R (1.56 mb)
Aparelhos de ar condicionado - DOC-091R (1.56 mb)
Aparelhos de ar condicionado - DOC-091RH (1.56 mb)
Aparelhos de ar condicionado - DOC-091RH (1.56 mb)