IMPORTANT: DO NOT OVER BEND THE DUCT (SEE FIGURE) Adapter A Rawlplugs Skruer max 120CM min 30CM Fig.8 Fig.9 Fig.10 30cm 30cm Fig.7 7 Your window kit has been designed to fit most standard Vertical and horizontal window applications, However, it may be necessary for you to improvise/modify some aspects of the installation procedures for certain types of window. Please refer to Fig. 11 & Fig. 11a for minimum and maximum window openings. Window Kit Installation Horizontal window Window Slider Kit Minimum:67.5cm(2.22ft). Maxmum:123cm(4.04ft). Window Slider Kit Minimum:67.5cm(2.22ft). Maxmum:123cm(4.04ft). Horizontal window This unit is equipped with a internal water tank, two full-safe switch mechanisms, one is used to control the water pump drainage, the other is used to monitor the water level inside the internal water tank. When the water level reaches a predetermined level, the full-safe switch mechanism is activated. The digital display shows P1 and the water full indicator light illuminates. Carefully move the unit outside, remove the rubber blockage from the back drainage hole and drain the water off. The unit will continue operating properly. Drain Tank Safety Feature MAINTENANCE 1) BE SURE TO UNPLUG THE UNIT BEFORE CLEANING. 2) DO NOT USE GASOLING, THINNER OR OTHER CHEMICALS TO CLEAN THE UNIT. 3) DO NOT WASH THE UNIT DIRECTLY UNDER A TAP OR USING A HOSE. THE ELECTRICAL CAUE DANGER. 4) IF THE POWER CORD IS DAMAGED, IT SHOULD BE REPAIRED BY MANUFACTURE OR ITS AGENCY. IMPORTANT: 1 AIR FILTER - Clean the air filter at least once every two weeks to prevent inferior fan operation because of dust. - Removal Pull out the filter cover and remove the air filter from the filter cover. - Cleaning Wash the air filter by immersing it gently in warm water (about 40OC/104OF) with a neutral detergent. Rinse the filter and dry it in a shady place. - Mounting Attach the air filter to the filter cover using the attachment hooks on the inner surface of the cover. Put the filter cover back to the unit. 2 UNIT ENCLOSURE - Use a lint-free cloth soaked with neutral detergent to clean the unit enclosure. Finished by a dry clean cloth. Fig.11 Fig.11a Fig.12 TROUBLE SHOOTING TROUBLES POSSIBLE CAUSES SUGGEST REMEDIES 1. UNIT DOES NOT START WHEN PRESSING 1/0 BUTTON -Water full indicator blinks, water tank is full. Dump the water in the water tank. -Room temperature is higher than the set temperature.(Heating mode) Reset the temperature. -Room temperature is lower than the set temperature.(Cooling mode) Reset the temperature. 2. NOT COOL ENOUGH -The windows or doors in the room are not closed. Make sure all the windows and doors are closed. -There are heat sources inside the room. Remove the heat sources if possible. -Exhaust air duct is not connected or blocked. Connect the duct and make sure it can function properly. -Temperature setting is too high. Decrease the set temperature. -Air filter is blocked by dust. Clean the air fil...
Este manual também é adequado para os modelos :Aparelhos de ar condicionado - DOC-091R (1.56 mb)
Aparelhos de ar condicionado - DOC-091R (1.56 mb)
Aparelhos de ar condicionado - DOC-091RH (1.56 mb)
Aparelhos de ar condicionado - DOC-091RH (1.56 mb)