Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Fujitsu, Modelo AUU24RC

Fabricante : Fujitsu
Arquivo Tamanho: 708.5 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


. Heat-pump type air conditioners use warm-air recirculation to warm your entire room. As a result, some time will be required after starting operation until your entire room becomes warm. * When Indoor and Outdoor Temperatures are High When both indoor and outdoor temperatures are high during use of the heating mode, the outdoor unit’s fan may stop at times. * Microcomputer-controlled Automatic Defrosting When the outside temperature is low and the humidity high, frost will collect on the outside unit, reducing heater efficiency. When this happens, the computer will automatically start the defrost cycle. During the defrost cycle, the indoor fan will shutdown and DEFROST will be displayed on the remote controller. It will take anywhere from 4 to 15 minutes before the air conditioner starts up again. Low Ambient Cooling When the outdoor temperature drops, the outdoor unit’s fans may switch to Low Speed, or one of the fans may stop intermittently. AUTO Restart In Event of Power Interruption . Should the power supply to the air conditioner be inter-. Use of other electrical appliances (electric shaver, etc.) or rupted by a power failure, the air conditioner will restart nearby use of a wireless radio transmitter may cause the automatically in the previously selected mode once the air conditioner to malfunction. In this event, temporarily power is restored. turn off the circuit breaker turn it on again and then use the remote controller to resume operation. Temperature and Humidity Range Cooling/Dry Mode *Heating Mode Outdoor temperature COOLING MODEL About 32 to 115 °F — HEAT & COOL MODEL AUU18RC AUU24RC About 32 to 115 °F About 32 to 75 °F (Reverse Cycle) AUU36RC AUU42RC About 17 to 75 °F Indoor temperature About 65 to 90 °F About 86 °F or less Indoor humidity About 80 % or less If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor unit, and drip onto the floor or other objects underneath. — . If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage. . Do not use this unit for any purposes other than the Cooling, (*)Heating, Dehumidifying, and air-circulation of rooms in ordinary dwellings. En-15 SYSTEM OPERATION Outdoor One remote controller can control up to 16 air conditioners. unit All the air conditioners can be operated with the same setting. Remote controller Unit No.1 Unit No.2 Unit No.16 Indoor unit To Use the ZONE CONTROL When the ZONE control button is pressed while multiple air conditioners are being centralized controlled, only the preset air conditioners stop. Press the ZONE control button. Preset units will stop. The ...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - AOU18RC (708.5 kb)
Aparelhos de ar condicionado - AUU36RC (708.5 kb)
Aparelhos de ar condicionado - AUU42RC (708.5 kb)
Aparelhos de ar condicionado - AOU18RC (708.5 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias