|
por este dispositivo também tem outras instruções :
Facilidade de uso
If you install the outdoor unit in a place exposed to strong winds or at a height, fix it to an appropriate support (wall or ground). 1. Place the outdoor unit as indicated on the top of the unit to let the discharged air out properly. 2. Fix the outdoor unit in level to an appropriate support using anchor bolts. 3. If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit so that the fan can operate correctly. 'Y' mm Rubber leg Model X Y ..09/12.. 457 254 ..18.. 543 319 ..24.. 660 340 • Secure the rubber leg to prevent the generation of noise and vibration. Designed to cut off residual vibration from outdoor unit to rack. (not supplied with product) Outdoor unit installed on the wall by rack • Ensure the wall will be able to suspend the weight of rack and outdoor unit; • Install the rack close to the column as much as possible; • Install proper grommet in order to reduce noise and residual vibration transferred by outdoor unit towards wall. Soft rubber designed to cut off vibration from rack to wall. (not supplied with product) Final Check and Trial Operation To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. Check the followings: • Strength of the installation site • Tightness of pipe connection to detect gas leak • Electric wiring connection • Heat-resistant insulation of the pipe • Drainage • Grounding conductor connection • Correct operation (follow the steps below) 1. Press the Power button and check the following: . The indicator on the indoor unit lights up. . The airflow blade opens and the fan gears up for operation. 2. Press the Mode button to select Cool or Heat mode. . In Cool mode, use Temp + or - button and set the temperature at 16°C. . In Heat mode, use Temp + or - button and set the temperature at 30°C. • Approximately 3~5 minutes later, outdoor unit will start to operate and the Cool or Warm air will blow out. • After 12 minutes of stationary condition check the indoor unit air treatment: Cooling mode (indoor unit check) . Inlet air temp. - Outlet air temp : From 10°K to 12°K ( indicative delta T) Heating mode (indoor unit check) . Outlet air temp. - Inlet air temp : From 11°K to 14°K (indicative delta T) In heating mode, the indoor fan motor can remain off to avoid cold air blown into conditioned space. 3. Press the Air swing button and check the following: . The airflow blades work properly. 4. Press the Power button to stop the operation. • When you complete the installation successfully, hand over this manual to the user for storage in a handy and safe place. Pump down procedure (when removing the product) 1. Turn on the air conditioner and select Cool mode to run the compressor for 3 minutes. 2 . Release the valve caps on High and Low pressure side. 3 . Use L wrench to close the valve on the high pressure side. 4 . Approximately 2 minutes after, close the valve on the low pressure side. 5 . Stop operation of the air conditioner. 6 . Disconnect the pipes. How to connect your extended power cables Items to prepare (compressor and insulation tape should be prepared by an installation technician.) 1. As shown in the figure, peel off the shields from the rubber/wire of the power cable. - Peel off 20 mm of the wire shields of the tube installed already. 2. Insert both sides of core wire of the power cable into the connection sleeve. 3. Using a compressor, compress the two points and flip it over and compress another two points in the same location. - The compression dimension should be 8.0. - After compressing it, pull both sides of the wire to make sure it is firmly pressed. 4. Wrap it with the insulation tape twice and position your contraction tube in the middle of the insulation tape. 5. Apply heat to the contraction tube to contract it. 6. After tube contraction work is completed, wrap it with the insulation tape to finish. Tools Crimping plier Connection sleeve (mm) Insulation tape Contraction tube (mm) Spec MH-14 20xO7.0(HxOD) Width 18mm 50xO8.0(LxOD) Shape (Unit: mm) Power cable (provided by us) 12060202020180 • After peeling off the tube wire, you must insert a contraction tube. Wire tube power cable 20 Connection sleeve Comp. dim. Compress it 4 times 5mm Insulation tape 40mm Contraction tube Insulation tape • In case of extending the electric wire, please DO NOT use a round-shaped pressing socket. - Incomplete wire connections can cause electric shock or a fire. Memo QUESTIONS OR COMMENTS? COUNTRY CALL OR VISIT US ONLINE AT ALBANIA 42 27 5755 AUSTRIA 0810 - SAMSUNG (7267864, € 0.07/min) BELGIUM 02-201-24-18 (Dutch) (French) BOSNIA 05 133 1999 BULGARIA 07001 33 11 CROATIA 062 SAMSUNG (062 726 7864) CZECH 800 - SAMSUNG (800-726786) DENMARK 70 70 19 70 FINLAND 030 - 6227 515 FRANCE 01 48 63 00 00 www.samsung.c...
Este manual também é adequado para os modelos :Aparelhos de ar condicionado - AQ09TSBNEUR (4.68 mb)
Aparelhos de ar condicionado - AQ09TSBXEUR (4.68 mb)
Aparelhos de ar condicionado - AQ09UGFN (4.68 mb)
Aparelhos de ar condicionado - AQ09UGFX (4.68 mb)