Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Panasonic, Modelo CS-22YA1E5

Fabricante : Panasonic
Arquivo Tamanho: 6.51 mb
Arquivo Nome :
Língua de Ensino: ruukenidms
Ir para baixar



Facilidade de uso


2. Press the set button for 5 seconds. Heating Press the button to turn off. Remote control display Transmitter Maximum distances: 8m Remote Control Preparation 1 Press and pull out 2 Insert AAA or R03 batteries (can be used ~ 1 year) 3 Press CLOCK 4 Set time 5 Confirm 6 Close the cover <3 —1_5 CZ-RWS1 (Heat-pump model) CZ-RWC1 (Cooling model) F567157.indb 6 11/20/2009 9:47:37 AM I 6 # OFF/ON (5) TO TURN ON OR OFF THE * POWERl UNIT POWER-* X TEMP TO SET TEMPERATURE Selection range: 16°C ~ 31°C. MODE TO SELECT OPERATION MODE AUTO mode - For your convenience • Unit selects operation mode according to temperature setting, outdoor and room temperature. HEAT mode - To enjoy warm air • Unit takes a while to warm up. FAN mode - To enables air circulation in the room COOL mode - To enjoy cool air DRY mode - To dehumidify the environment • Unit operates at low fan speed to give a gentle cooling operation. • During soft dry operation, the indoor fan operates at a low fan speed. • The louvers movement might not align with the remote control display. fan speed] TO SELECT FAN SPEED (3 OPTIONS) AUTO —► LOW —► MEDIUM -> HIGH a 3 For AUTO, the indoor fan speed is automatically adjusted according to the operation mode. If the operation mode is set to Fan, the fan speed will be fixed at MEDIUM regardless of the temperature setting. AUTO ,,INU| TO ADJUST AIRFLOW ■MANUAL DIRECTION • Keeps the room ventilated. • The air is discharge evenly through 4 output vents. .. AUT01 h AUTO 2 h AUTO 3 ‘UTO *W\ 1 • There are 3 options for auto vertical airflow direction. • The vertical airflow louver swings up and down automatically. • Do not adjust the vertical airflow direction louvers by hand. MANUAL ) ^ -* ✓ -* J -* J • There are 4 options for manual vertical airflow direction. • The airflow direction can be adjusted as desired by using remote control. TO SET DAILY TIMER To turn ON or OFF the unit at a preset time. 2 1 — TIMER « * >. SELECT 3 IÎSET Select ON or OFF timer. Set the time. Confirm. To cancel ON or OFF timer, press When ON timer is set, the unit may start early before the actual set time in order to achieve the desired temperature on time. Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Remote Control preparation. The timer closest to the current time will be activated first. If timer is cancelled manually, you can restore the previous setting by pressing set . If the main power is switched off for an hour or more, the clock and timer will need to be set again. OPTIONAL SETTINGS To avoid unintentional operation, you can assign a different address to each indoor unit. Press repeatedly to select your desired address setting. ► Group —► Address 1 —► Address 2 —► Address 3 a • By default, ADDRESS 1 is selected. You do not need to change this setting for normal operation. • If the address is set to GROUP, more than one indoor unit can be operated at the same time. • Press to restore the remote control’s default RC RESET setting. €• SET AC RESET Not used in normal operations. HINT • Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode. F567157.indb 7 11/20/2009 9:47:38 AM I 7 ENGLISH ф -PRODUCT OVERVIEW & OPERATIONS (WIRED REMOTE CONTROL) Air is discharged evenly Intake grille Г XL Panasonic montuewedtHu fri satsun °n" >гт FAN SPEED AUTO AUTO AIR SWING AUTO 1 / i •-> SELECT DOWiT CANCEL I AUTO MANUAL I DOWN «*>! *! rn ko hr L--JrEOONOM^ AIR SWING -1 ft) ""OUR WASH I v- I VENTILATION TEST RUN FILTER RESET and * r ECONOMY- For normal operation, the odour wash, • , ventilation buttons are not in use. (2 O' Remote Control Preparation A r, SELECT 1 Press ^ 2 Press to set day 3 Confirm 4 Repeat steps 2 and 3 to set the current time. CZ-RT1 F567157.indb В Ф 11/20/2009 9:47:39 AM I 8 # ..... OFF/ON ® - TO TURN ON OR OFF THE UNIT UP DOWN W TO SET TEMPERATURE Selection range: 16°C ~ 31°C. TO SELECT OPERATION MODE AUTO mode - For your convenience • Unit selects operation mode according to temperature setting, outdoor and room temperature. HEAT mode - To enjoy warm air • Unit takes a while to warm up. FAN mode - To enables air circulation in the room COOL mode - To enjoy cool air DRY mode - To dehumidify the environment • Unit operates at low fan speed to give a gentle cooling operation. • During soft dry operation, the indoor fan operates at a low fan speed. • The louvers movement might not align with the remote control display. FAN SPEED TO SELECT FAN SPEED (3 OPTIONS) AUTO —► LO —► MED —► HI r 3 For AUTO, the indoor fan speed is automatically adjusted according to the operation mode. If the operation mode is set to Fan, the fan speed will be fixed at MED regardless of t...

Este manual também é adequado para os modelos :
Aparelhos de ar condicionado - CS-28YA1E5 (6.51 mb)
Aparelhos de ar condicionado - CS-36YA1E5 (6.51 mb)
Aparelhos de ar condicionado - CS-45YA1E5 (6.51 mb)
Aparelhos de ar condicionado - CS-56YA1E5 (6.51 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias