|
Facilidade de uso
Children should be supervised to ensure that they do not play with the appliance. OPERATION CONDITIONOPERATION CONDITION Use this air conditioner under the following temperature range Temperature (°C) Indoor Outdoor *DBT *WBT *DBT *WBT COOLING Maximum 32 23 43 26 Minimum 16 11 16 11 * DBT: Dry bulb temperature * WBT: Wet bulb temperature Replacement or installation of power plugs shall be performed by authorized/ qualified personnel only. The wires in this mains lead are coloured in accordance with the following code: Terminals wires live neutral colours (GB Standard) brown blue Red Black green-yellow earthGreen/Yellow Wiring colour may vary depending on a country wiring code’s standard. ENGLISHTABLE OF CONTENTSTABLE OF CONTENTS SAFETY PRECAUTIONS 2 REGULATORY INFORMATION 3 PRODUCT OVERVIEW & OPERATIONS 4~5 CARE & CLEANING 6 TROUBLESHOOTING 7 QUICK GUIDE BACK COVER NOTE :NOTE : The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement. Information for Users on Collection and Disposal of Old Equipment and used Batteries [Information on Disposal in other Countries outside the European Union] These symbols are only valid in the European Union. If you wish to discard these items, please contact yourlocal authorities or dealer and ask for the correct method of disposal. Note for the battery symbol (bottom two symbol examples): This symbol might be used in combination with a chemical symbol. In this case it complies with therequirement set by the Directive for the chemical involved. Pb • Do not switch ON the unit when waxing the floor. After waxing, aerate the room properly before operating the unit. • Do not install the unit in oily and smoky areas. 4 PRODUCT OVERVIEW & OPERATIONS TO TURN ON OR OFF THE UNIT POWER • Please be aware of the OFF indication on the remote control display to prevent the unit from starting/stopping improperly. TO SET TEMPERATURE • For cool and dry modes, the range of temperature for selection is 16°C ~ 30°C. • Operating the unit within the recommended temperature could induce energy saving. COOL mode : 26°C ~ 28°C. DRY mode : 1°C ~ 2°C lower than room temperature. TO SELECT OPERATION MODE AUTO mode - For your convenience • Unit selects the operation mode according to the room temperature. • Once auto mode is selected, the unit will operate at the standard setting temperature. • To change the standard setting temperature, press for “HI” or for “LO”. Room temperature Operation mode Standard setting temperature HI (+2°C) LO (-2°C) 23°C & above Cool 25°C 27°C 23°C Below 23°C Dry 22°C 24°C 20°C COOL mode - To enjoy cool air DRY mode - To dehumidify the environment • Unit operates at low fan speed to give a gentle cooling operation. Front panel Receiver Auto OFF/ON button • Used when remote control is misplaced or malfunction. Action Mode Press once. Auto Press and hold until 1 beep is heard, then release. Cooling Press the button to turn off. e-ion AIR PURIFYING SYSTEM Do not touch during operation e-ion fi lters e-ion charging wire Active e-ion Generator Maximum distances: 8m Horizontal airfl ow direction louver • Manually adjustable. Vertical airfl ow direction louver • Do not adjust by hand. Remote control display INDICATOR (Red/Orange/Blue) (Green) (Orange) (Orange) (Orange) (Blue) • , and can be activated in all modes and can be cancelled by pressing therespective button again. • and can not be selected at the same time. • and can be activated even when the unit is turned off. In this condition, fan speed and air swingcan not be adjusted. ENGLISH TOSET THE TIMERTO SET THE TIMER • To turn ON or OFF the unit at a preset time. TIMER Select ON or OFF timer. Set the time. Confirm. • To cancel ON or OFF timer, press or then press . • When ON Timer is set, the unit may start earlier (up to 15 minutes) before the actual set time in order to achieve the desired temperature on time. • Timer operation is based on the clock set in the remote control and repeats daily once set. For clock setting, please refer to Remote Control Preparation at back cover. • If timer is cancelled manually or due to power failure, you can restore the previous setting (once power is resumed) by pressing . OPTIONAL SETTINGSOPTIONAL SETTINGS Patrol starts automatically with the unit switched on with . Press and hold for 5 seconds, then release to disable or restore this setting. Press and hold for 5 seconds to dim or restore the unit’s indicator brightness. Press and hold for approximately 10 seconds to show temperature setting in °C or °F. Press and hold for approximately 5 seconds to show 12-hour (am/pm) or 24-hour time indication. Press to restore the remote control’s default setting. Not used in normal operations. Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode. TO SELECT FAN SPEED (3 OPTIONS) • For AUTO, the indoor fan speed is automaticallyadjusted according t...
Este manual também é adequado para os modelos :Aparelhos de ar condicionado - CS-C9JKD (3.26 mb)
Aparelhos de ar condicionado - CS-C12JKD (3.26 mb)