Log:
Sort : Nome ↑   Downloads   Avaliação   Tamanho ↑  
Downloads : 6   Arquivo Tamanho: 246 kb   Fabricante : Haier  
Categoria : Aparelhos de ar condicionado
@name

Company Printed in the U.S.A. D&S 1-800-448-5872 All specifications and illustrations subject to change without notice and without incurring obligations.

Downloads : 8   Arquivo Tamanho: 877 kb   Fabricante : Haier  
Categoria : Aparelhos de ar condicionado
@name

Unscrew the screw at both ends of the swing plate. [Dismantle and install swingplate ] 3. Install swing plate Lightly rotate swing plate to insert the ridge at both ends of the outlet into the groove and then screw up. 2. Take off air-filter 9 Maintenance (For series 362, 422, 482, 602 ) Clean the air filter Instructions : When not for cleaning, do not dismantle the air filter, otherwise it may cause trouble. When the air conditioner is used in a dusty environment, the air filter should be clean

Downloads : 9   Arquivo Tamanho: 174 kb   Fabricante : Haier  
Categoria : Aparelhos de ar condicionado
@name

This will compress the roof gasket to approximately 1/2". The bolts are self locking so over tightening is not necessary. CAUTION If bolts are left loose there may not be an adequate roof seal or if over tightened, damage may occur to the air conditioner base or ceiling template. Tighten to torque specifications listed in this manual. Disconnect 120 volt AC. Failure to follow these instructions could create a shock hazard causing death or severe personal injury. Reach up into the return air open

Downloads : 14   Arquivo Tamanho: 352 kb   Fabricante : Haier  
Categoria : Aparelhos de ar condicionado
@name

Dometic cannot assist in sizing an inverter/generator as the manufacturer of that item is best suited for that task. Damage to a unit caused by an inadequate inverter/generator is not covered under warranty. Safe Operation of Carry-On 1. Use cord labled with LCDI or AFCI to connect to power source (see warning). 2. Using the Carry-On is not recommended while the boat is under way. 3. Prevent accidents or damage to Carry-On. Always carry or move unit using the handles. Unplug at receptacle and Ca

Downloads : 6   Arquivo Tamanho: 623 kb   Fabricante : Haier  
Categoria : Aparelhos de ar condicionado

Downloads : 9   Arquivo Tamanho: 896 kb   Fabricante : Haier  
Categoria : Aparelhos de ar condicionado
@name

The waste battery shall be disposed properly. 7. The indoor unit installation height is at least 2.5m. Rated Maximum MinimumCooling Indoor DB C 27 32 18WB C 19 23 14outdoor DB C 35 43 10WB C 24 26 6Heating Indoor DB C 20 27 15WB C 14.5 ---outdoor DB C 7 24 -15WB C 6 18 - 2 3 Main Points of Operation Operation of Air Conditioner When the environmental humidity is great, water maybe dripped from the air outlet in cooling or drying mode. 3-minute Protection Function If restart the unit immediately

Downloads : 9   Arquivo Tamanho: 745 kb   Fabricante : Haier  
Categoria : Aparelhos de ar condicionado
@name

Suspending bracket Ceiling A (160) 20 Over Distance between suspending bolts 460mm Overlap between ceiling and ornament panel shall be 15mm Suspending bolts Ceiling Ornament panel (For series 14 18 ) 630(Ornament panel)600(Ceiling opening)570(Indoor unit) 630(Ornament panel) 600(Ceiling opening) 570(Indoor unit) (2) Cut an opening in ceiling for installation if necessary. (when ceiling already exists.) Refer to paper pattern for dimension of ceiling hole. Connect all pipings (refrigerant, water

Downloads : 15   Arquivo Tamanho: 174 kb   Fabricante : Haier  
Categoria : Aparelhos de ar condicionado
@name

2. Mounting on the roof of a recreational vehicle. 3. Roof construction with rafters/joists on minimum of 16 inch centers. 4. Minimum of 2.00 inches and maximum of 4.00 inches distance between roof to ceiling of recreational vehicle. Alternate installation methods will allow for roofs more than 4.00 inches thick. C. The ability of the air conditioner to maintain the desired inside temperature depends on the heat gain of the RV. Some preventative measures taken by the occupants of the RV can redu

Downloads : 8   Arquivo Tamanho: 602 kb   Fabricante : Haier  
Categoria : Aparelhos de ar condicionado
@name

The machine is adaptive in following situation 1. Applicable ambient temperature range: Rated Maximum MinimumCooling Indoor DB C 27 32 18WB C 19 23 14outdoor DB C 35 43 10WB C 24 26 6Heating Indoor DB C 20 27 15WB C 14.5 ---outdoor DB C 7 24 -7WB C 6 18 - 2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. 3. If the fuse on PC board is broken, please change it with the type of T 3.15A /250VAC 4. The wiring method should be

Downloads : 12   Arquivo Tamanho: 2 mb   Fabricante : Haier  
Categoria : Aparelhos de ar condicionado
@name

PROHIBITION PROHIBITION PROHIBITION PROHIBITION PROHIBITION Do not install the unit near a fireplaceor other heating apparatus. Check good condition of the installation stand Do not pour water onto the unitfor cleaning PROHIBITION Do not place animals or plants inthe direct path of the air flow Do not place any objects on orclimb on the unit. Do not place flower vase or watercontainers on the top of the unit. PROHIBITION CAUTION 4 Parts and Functions Indoor unit Outlet Inlet Inlet grille Anion g





categorias